Cargando…

Quiet standing: The Single Inverted Pendulum model is not so bad after all

In the study of balance and postural control the (Single) Inverted Pendulum model (SIP) has been taken for a long time as an acceptable paradigm, with the implicit assumption that only ankle rotations are relevant for describing and explaining sway movements. However, more recent kinematic analysis...

Descripción completa

Detalles Bibliográficos
Autores principales: Morasso, Pietro, Cherif, Amel, Zenzeri, Jacopo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6428281/
https://www.ncbi.nlm.nih.gov/pubmed/30897124
http://dx.doi.org/10.1371/journal.pone.0213870
_version_ 1783405378514452480
author Morasso, Pietro
Cherif, Amel
Zenzeri, Jacopo
author_facet Morasso, Pietro
Cherif, Amel
Zenzeri, Jacopo
author_sort Morasso, Pietro
collection PubMed
description In the study of balance and postural control the (Single) Inverted Pendulum model (SIP) has been taken for a long time as an acceptable paradigm, with the implicit assumption that only ankle rotations are relevant for describing and explaining sway movements. However, more recent kinematic analysis of quiet standing revealed that hip motion cannot be neglected at all and that ankle-hip oscillatory patterns are characterized by complex in-phase and anti-phase interactions, suggesting that the SIP model should be substituted by a DIP (Double Inverted Pendulum) model. It was also suggested that DIP control could be characterized as a kind of optimal bi-axial active controller whose goal is minimizing the acceleration of the global CoM (Center of Mass). We propose here an alternative where active feedback control is applied in an intermittent manner only to the ankle joint, whereas the hip joint is stabilized by a passive stiffness mechanism. The active control impulses are delivered to the ankle joint as a function of the delayed state vector (tilt rotation angle + tilt rotational speed) of a Virtual Inverted Pendulum (VIP), namely a pendulum that links the ankle to the CoM, embedded in the real DIP. Simulations of such DIP/VIP model, with the hybrid control mechanism, show that it can reproduce the in-phase/anti-phase interaction patterns of the two joints described by several experimental studies. Moreover, the simulations demonstrate that the DIP/VIP model can also reproduce the measured minimization of the CoM acceleration, as an indirect biomechanical consequence of the dynamic interaction between the active control of the ankle joint and the passive control of the hip joint. We suggest that although the SIP model is literally false, because it ignores the ankle-hip coordination, it is functionally correct and practically acceptable for experimental studies that focus on the postural oscillations of the CoM.
format Online
Article
Text
id pubmed-6428281
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-64282812019-04-02 Quiet standing: The Single Inverted Pendulum model is not so bad after all Morasso, Pietro Cherif, Amel Zenzeri, Jacopo PLoS One Research Article In the study of balance and postural control the (Single) Inverted Pendulum model (SIP) has been taken for a long time as an acceptable paradigm, with the implicit assumption that only ankle rotations are relevant for describing and explaining sway movements. However, more recent kinematic analysis of quiet standing revealed that hip motion cannot be neglected at all and that ankle-hip oscillatory patterns are characterized by complex in-phase and anti-phase interactions, suggesting that the SIP model should be substituted by a DIP (Double Inverted Pendulum) model. It was also suggested that DIP control could be characterized as a kind of optimal bi-axial active controller whose goal is minimizing the acceleration of the global CoM (Center of Mass). We propose here an alternative where active feedback control is applied in an intermittent manner only to the ankle joint, whereas the hip joint is stabilized by a passive stiffness mechanism. The active control impulses are delivered to the ankle joint as a function of the delayed state vector (tilt rotation angle + tilt rotational speed) of a Virtual Inverted Pendulum (VIP), namely a pendulum that links the ankle to the CoM, embedded in the real DIP. Simulations of such DIP/VIP model, with the hybrid control mechanism, show that it can reproduce the in-phase/anti-phase interaction patterns of the two joints described by several experimental studies. Moreover, the simulations demonstrate that the DIP/VIP model can also reproduce the measured minimization of the CoM acceleration, as an indirect biomechanical consequence of the dynamic interaction between the active control of the ankle joint and the passive control of the hip joint. We suggest that although the SIP model is literally false, because it ignores the ankle-hip coordination, it is functionally correct and practically acceptable for experimental studies that focus on the postural oscillations of the CoM. Public Library of Science 2019-03-21 /pmc/articles/PMC6428281/ /pubmed/30897124 http://dx.doi.org/10.1371/journal.pone.0213870 Text en © 2019 Morasso et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Morasso, Pietro
Cherif, Amel
Zenzeri, Jacopo
Quiet standing: The Single Inverted Pendulum model is not so bad after all
title Quiet standing: The Single Inverted Pendulum model is not so bad after all
title_full Quiet standing: The Single Inverted Pendulum model is not so bad after all
title_fullStr Quiet standing: The Single Inverted Pendulum model is not so bad after all
title_full_unstemmed Quiet standing: The Single Inverted Pendulum model is not so bad after all
title_short Quiet standing: The Single Inverted Pendulum model is not so bad after all
title_sort quiet standing: the single inverted pendulum model is not so bad after all
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6428281/
https://www.ncbi.nlm.nih.gov/pubmed/30897124
http://dx.doi.org/10.1371/journal.pone.0213870
work_keys_str_mv AT morassopietro quietstandingthesingleinvertedpendulummodelisnotsobadafterall
AT cherifamel quietstandingthesingleinvertedpendulummodelisnotsobadafterall
AT zenzerijacopo quietstandingthesingleinvertedpendulummodelisnotsobadafterall