Cargando…

Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle

BACKGROUND: Both universal goniometer and electro-goniometer are used for measuring joint range of motion in physiotherapy. Active knee extension test is a way to assess hamstring shortness in patients with chronic low back pain. The aim of this study was to assess universal goniometer and electro-g...

Descripción completa

Detalles Bibliográficos
Autores principales: Shamsi, MohammadBagher, Mirzaei, Maryam, Khabiri, Seyyed Saeed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6431043/
https://www.ncbi.nlm.nih.gov/pubmed/30949343
http://dx.doi.org/10.1186/s13102-019-0116-x
_version_ 1783405874004361216
author Shamsi, MohammadBagher
Mirzaei, Maryam
Khabiri, Seyyed Saeed
author_facet Shamsi, MohammadBagher
Mirzaei, Maryam
Khabiri, Seyyed Saeed
author_sort Shamsi, MohammadBagher
collection PubMed
description BACKGROUND: Both universal goniometer and electro-goniometer are used for measuring joint range of motion in physiotherapy. Active knee extension test is a way to assess hamstring shortness in patients with chronic low back pain. The aim of this study was to assess universal goniometer and electro-goniometer reliability in measuring knee angle during active knee extension test. METHODS: This was an intra-examiner reliability study between three measurements of knee extension angle that conducted on 45 patients with chronic low back pain having short hamstring muscle that referring to Kermanshah University of Medical Sciences clinic from 2016 to 2017. Knee extension angle was measured three times during active knee extension test with both universal goniometer and electro-goniometer. The measurement of knee extension angle was done at the beginning, middle and the end of one single session by one experienced physiotherapist. The intra-class correlation coefficient (ICC) and standard error of measurements (SEM) were used to quantify intra-examiner reliability. RESULTS: For both methods, the reliability test values were found to be greater than 0.7 in the range of 0.92 to 0.99 (CI 95% ranged over = 0.94 to 0.99), which are classified as good reliability. The SEMs ranged from 1.04° to 2.16° for both scales. CONCLUSION: Universal goniometer in clinical evaluations of patients (as they are easy to be employed) and electro-goniometer in laboratory studies (as they are more accurate) are reliable.
format Online
Article
Text
id pubmed-6431043
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-64310432019-04-04 Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle Shamsi, MohammadBagher Mirzaei, Maryam Khabiri, Seyyed Saeed BMC Sports Sci Med Rehabil Research Article BACKGROUND: Both universal goniometer and electro-goniometer are used for measuring joint range of motion in physiotherapy. Active knee extension test is a way to assess hamstring shortness in patients with chronic low back pain. The aim of this study was to assess universal goniometer and electro-goniometer reliability in measuring knee angle during active knee extension test. METHODS: This was an intra-examiner reliability study between three measurements of knee extension angle that conducted on 45 patients with chronic low back pain having short hamstring muscle that referring to Kermanshah University of Medical Sciences clinic from 2016 to 2017. Knee extension angle was measured three times during active knee extension test with both universal goniometer and electro-goniometer. The measurement of knee extension angle was done at the beginning, middle and the end of one single session by one experienced physiotherapist. The intra-class correlation coefficient (ICC) and standard error of measurements (SEM) were used to quantify intra-examiner reliability. RESULTS: For both methods, the reliability test values were found to be greater than 0.7 in the range of 0.92 to 0.99 (CI 95% ranged over = 0.94 to 0.99), which are classified as good reliability. The SEMs ranged from 1.04° to 2.16° for both scales. CONCLUSION: Universal goniometer in clinical evaluations of patients (as they are easy to be employed) and electro-goniometer in laboratory studies (as they are more accurate) are reliable. BioMed Central 2019-03-22 /pmc/articles/PMC6431043/ /pubmed/30949343 http://dx.doi.org/10.1186/s13102-019-0116-x Text en © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Shamsi, MohammadBagher
Mirzaei, Maryam
Khabiri, Seyyed Saeed
Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle
title Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle
title_full Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle
title_fullStr Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle
title_full_unstemmed Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle
title_short Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle
title_sort universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6431043/
https://www.ncbi.nlm.nih.gov/pubmed/30949343
http://dx.doi.org/10.1186/s13102-019-0116-x
work_keys_str_mv AT shamsimohammadbagher universalgoniometerandelectrogoniometerintraexaminerreliabilityinmeasuringthekneerangeofmotionduringactivekneeextensiontestinpatientswithchroniclowbackpainwithshorthamstringmuscle
AT mirzaeimaryam universalgoniometerandelectrogoniometerintraexaminerreliabilityinmeasuringthekneerangeofmotionduringactivekneeextensiontestinpatientswithchroniclowbackpainwithshorthamstringmuscle
AT khabiriseyyedsaeed universalgoniometerandelectrogoniometerintraexaminerreliabilityinmeasuringthekneerangeofmotionduringactivekneeextensiontestinpatientswithchroniclowbackpainwithshorthamstringmuscle