Cargando…

The value of four stage vestibular hydrops grading and asymmetric perilymphatic enhancement in the diagnosis of Menière’s disease on MRI

PURPOSE: There is still a clinical-radiologic discrepancy in patients with Menière’s disease (MD). Therefore, the purpose of this study was to investigate the reliability of current MRI endolymphatic hydrops (EH) criteria according to Baráth in a larger study population and the clinical utility of n...

Descripción completa

Detalles Bibliográficos
Autores principales: Bernaerts, Anja, Vanspauwen, Robby, Blaivie, Cathérine, van Dinther, Joost, Zarowski, Andrzej, Wuyts, Floris L., Vanden Bossche, Stephanie, Offeciers, Erwin, Casselman, Jan W., De Foer, Bert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6431299/
https://www.ncbi.nlm.nih.gov/pubmed/30719545
http://dx.doi.org/10.1007/s00234-019-02155-7
Descripción
Sumario:PURPOSE: There is still a clinical-radiologic discrepancy in patients with Menière’s disease (MD). Therefore, the purpose of this study was to investigate the reliability of current MRI endolymphatic hydrops (EH) criteria according to Baráth in a larger study population and the clinical utility of new imaging signs such as a supplementary fourth low-grade vestibular EH and the degree of perilymphatic enhancement (PE) in patients with Menière’s disease (MD). METHODS: This retrospective study included 148 patients with probable or definite MD according to the 2015 American Academy of Otolaryngology, Head and Neck Surgery criteria who underwent a 4-h delayed intravenous Gd-enhanced 3D-FLAIR MRI between January 2015 and December 2016. Vestibular EH, vestibular PE, cochlear EH, and cochlear PE were reviewed twice by three experienced readers. Cohen’s Kappa and multivariate logistic regression were used for analysis. RESULTS: The intra- and inter-reader reliability for the grading of vestibular-cochlear EH and PE was excellent (0.7 < kappa < 0.9). The two most distinctive characteristics to identify MD are cochlear PE and vestibular EH which combined gave a sensitivity and specificity of 79.5 and 93.6%. By addition of a lower grade vestibular EH, the sensitivity improved to 84.6% without losing specificity (92.3%). Cochlear EH nor vestibular PE showed added-value. CONCLUSIONS: MRI using vestibular-cochlear EH and PE grading system is a reliable technique. A four-stage vestibular EH grading system in combination with cochlear PE assessment gives the best diagnostic accuracy to detect MD.