Cargando…
Perforation of saphenous vein graft with mediastinal haemorrhage leading to near closure of distal graft segment
Perforations of saphenous venous grafts during coronary angioplasty are rare and potentially lethal. The objective of this clinical case report is to highlight this unusual complication and necessary treatment. A 76-year-old woman, 3 months after coronary artery bypass grafting (left internal mammar...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6431758/ https://www.ncbi.nlm.nih.gov/pubmed/30923615 http://dx.doi.org/10.1177/2050313X19838745 |
_version_ | 1783405979475378176 |
---|---|
author | Wyderka, Rafał Adamowicz, Jakub Nowicki, Przemysław Ciapka, Adam Kędzierski, Bartłomiej Jaroch, Joanna |
author_facet | Wyderka, Rafał Adamowicz, Jakub Nowicki, Przemysław Ciapka, Adam Kędzierski, Bartłomiej Jaroch, Joanna |
author_sort | Wyderka, Rafał |
collection | PubMed |
description | Perforations of saphenous venous grafts during coronary angioplasty are rare and potentially lethal. The objective of this clinical case report is to highlight this unusual complication and necessary treatment. A 76-year-old woman, 3 months after coronary artery bypass grafting (left internal mammary artery to left anterior descendant artery, saphenous vein graft to obtuse marginal, saphenous vein graft to right coronary artery), demonstrated typical signs of acute coronary syndrome. Coronary angiogram revealed, inter alia, two critical lesions in saphenous vein graft to right coronary artery. Percutaneous coronary intervention was performed with placement of two drug-eluting stents, complicated by a vessel rupture and heavy extravasation of contrast. A polyurethane-covered stent was then deployed and successfully sealed the vascular wall. In a computed tomography of the chest, a mediastinal haematoma near the heart base and right heart margin was found. Subsequently, this intrathoracic bleeding caused external impression on saphenous vein graft to right coronary artery, leading to near occlusion of the vessel with recurrence of chest pain and ST-segment elevation in inferior wall electrocardiogram leads. Immediate coronary angiography and drug-eluting stent implantation was performed. During, further, in-hospital follow-up, patient was free of chest pain; computed tomography scan performed after 10 days revealed regression of haematoma. Clinicians must remain alert to the potential of life-threatening complications associated with saphenous venous graft angioplasty, as their recognition is critical to institution of prompt, appropriate therapy. |
format | Online Article Text |
id | pubmed-6431758 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-64317582019-03-28 Perforation of saphenous vein graft with mediastinal haemorrhage leading to near closure of distal graft segment Wyderka, Rafał Adamowicz, Jakub Nowicki, Przemysław Ciapka, Adam Kędzierski, Bartłomiej Jaroch, Joanna SAGE Open Med Case Rep Case Report Perforations of saphenous venous grafts during coronary angioplasty are rare and potentially lethal. The objective of this clinical case report is to highlight this unusual complication and necessary treatment. A 76-year-old woman, 3 months after coronary artery bypass grafting (left internal mammary artery to left anterior descendant artery, saphenous vein graft to obtuse marginal, saphenous vein graft to right coronary artery), demonstrated typical signs of acute coronary syndrome. Coronary angiogram revealed, inter alia, two critical lesions in saphenous vein graft to right coronary artery. Percutaneous coronary intervention was performed with placement of two drug-eluting stents, complicated by a vessel rupture and heavy extravasation of contrast. A polyurethane-covered stent was then deployed and successfully sealed the vascular wall. In a computed tomography of the chest, a mediastinal haematoma near the heart base and right heart margin was found. Subsequently, this intrathoracic bleeding caused external impression on saphenous vein graft to right coronary artery, leading to near occlusion of the vessel with recurrence of chest pain and ST-segment elevation in inferior wall electrocardiogram leads. Immediate coronary angiography and drug-eluting stent implantation was performed. During, further, in-hospital follow-up, patient was free of chest pain; computed tomography scan performed after 10 days revealed regression of haematoma. Clinicians must remain alert to the potential of life-threatening complications associated with saphenous venous graft angioplasty, as their recognition is critical to institution of prompt, appropriate therapy. SAGE Publications 2019-03-22 /pmc/articles/PMC6431758/ /pubmed/30923615 http://dx.doi.org/10.1177/2050313X19838745 Text en © The Author(s) 2019 http://www.creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Case Report Wyderka, Rafał Adamowicz, Jakub Nowicki, Przemysław Ciapka, Adam Kędzierski, Bartłomiej Jaroch, Joanna Perforation of saphenous vein graft with mediastinal haemorrhage leading to near closure of distal graft segment |
title | Perforation of saphenous vein graft with mediastinal haemorrhage leading to near closure of distal graft segment |
title_full | Perforation of saphenous vein graft with mediastinal haemorrhage leading to near closure of distal graft segment |
title_fullStr | Perforation of saphenous vein graft with mediastinal haemorrhage leading to near closure of distal graft segment |
title_full_unstemmed | Perforation of saphenous vein graft with mediastinal haemorrhage leading to near closure of distal graft segment |
title_short | Perforation of saphenous vein graft with mediastinal haemorrhage leading to near closure of distal graft segment |
title_sort | perforation of saphenous vein graft with mediastinal haemorrhage leading to near closure of distal graft segment |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6431758/ https://www.ncbi.nlm.nih.gov/pubmed/30923615 http://dx.doi.org/10.1177/2050313X19838745 |
work_keys_str_mv | AT wyderkarafał perforationofsaphenousveingraftwithmediastinalhaemorrhageleadingtonearclosureofdistalgraftsegment AT adamowiczjakub perforationofsaphenousveingraftwithmediastinalhaemorrhageleadingtonearclosureofdistalgraftsegment AT nowickiprzemysław perforationofsaphenousveingraftwithmediastinalhaemorrhageleadingtonearclosureofdistalgraftsegment AT ciapkaadam perforationofsaphenousveingraftwithmediastinalhaemorrhageleadingtonearclosureofdistalgraftsegment AT kedzierskibartłomiej perforationofsaphenousveingraftwithmediastinalhaemorrhageleadingtonearclosureofdistalgraftsegment AT jarochjoanna perforationofsaphenousveingraftwithmediastinalhaemorrhageleadingtonearclosureofdistalgraftsegment |