Cargando…

Augmentative antirotational plating provided a significantly higher union rate than exchanging reamed nailing in treatment for femoral shaft aseptic atrophic nonunion - retrospective cohort study

BACKGROUND: Atrophic nonunion of femoral shaft fracture after intramedullary (IM) nailing is uncommon. The treatment for femoral shaft aseptic atrophic non-union remained controversial. The aim of this study was to compare the surgical results between exchanging reamed nailing (ERN) and augmentative...

Descripción completa

Detalles Bibliográficos
Autores principales: Lai, Po-Ju, Hsu, Yung-Heng, Chou, Ying-Chao, Yeh, Wen-Ling, Ueng, Steve W. N., Yu, Yi-Hsun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6434807/
https://www.ncbi.nlm.nih.gov/pubmed/30909909
http://dx.doi.org/10.1186/s12891-019-2514-3
_version_ 1783406544245751808
author Lai, Po-Ju
Hsu, Yung-Heng
Chou, Ying-Chao
Yeh, Wen-Ling
Ueng, Steve W. N.
Yu, Yi-Hsun
author_facet Lai, Po-Ju
Hsu, Yung-Heng
Chou, Ying-Chao
Yeh, Wen-Ling
Ueng, Steve W. N.
Yu, Yi-Hsun
author_sort Lai, Po-Ju
collection PubMed
description BACKGROUND: Atrophic nonunion of femoral shaft fracture after intramedullary (IM) nailing is uncommon. The treatment for femoral shaft aseptic atrophic non-union remained controversial. The aim of this study was to compare the surgical results between exchanging reamed nailing (ERN) and augmentative antirotational plating (AAP) for femoral shaft aseptic atrophic nonunion. METHODS: We retrospectively reviewed the patients with femoral shaft nonunion between the year of 2014 and 2015. The patients with nonunion after plate osteosynthesis, septic nonunion, hypertrophic nonunion, additional surgery during revision surgery were excluded. All the patients were followed up at least 12 months. RESULTS: Overall, the union rate after revision surgery was 70.8%. The union rate was significantly higher in the AAP group than in the ERN group. Operating time was also significantly shorter in the AAP group. Regarding the location of nonunion, the union rate was comparable between groups for isthmic nonunions. However, for non-isthmic nonunions, the union rate was significantly higher and operating time was significantly shorter in the AAP group. CONCLUSION: AAP showed an overall higher union rate for management of femoral shaft aseptic atrophic nonunion compared with ERN. Especially for non-isthmic femoral shaft atrophic nonunions, AAP provided a significantly higher union rate and significantly shorter operating time.
format Online
Article
Text
id pubmed-6434807
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-64348072019-04-08 Augmentative antirotational plating provided a significantly higher union rate than exchanging reamed nailing in treatment for femoral shaft aseptic atrophic nonunion - retrospective cohort study Lai, Po-Ju Hsu, Yung-Heng Chou, Ying-Chao Yeh, Wen-Ling Ueng, Steve W. N. Yu, Yi-Hsun BMC Musculoskelet Disord Research Article BACKGROUND: Atrophic nonunion of femoral shaft fracture after intramedullary (IM) nailing is uncommon. The treatment for femoral shaft aseptic atrophic non-union remained controversial. The aim of this study was to compare the surgical results between exchanging reamed nailing (ERN) and augmentative antirotational plating (AAP) for femoral shaft aseptic atrophic nonunion. METHODS: We retrospectively reviewed the patients with femoral shaft nonunion between the year of 2014 and 2015. The patients with nonunion after plate osteosynthesis, septic nonunion, hypertrophic nonunion, additional surgery during revision surgery were excluded. All the patients were followed up at least 12 months. RESULTS: Overall, the union rate after revision surgery was 70.8%. The union rate was significantly higher in the AAP group than in the ERN group. Operating time was also significantly shorter in the AAP group. Regarding the location of nonunion, the union rate was comparable between groups for isthmic nonunions. However, for non-isthmic nonunions, the union rate was significantly higher and operating time was significantly shorter in the AAP group. CONCLUSION: AAP showed an overall higher union rate for management of femoral shaft aseptic atrophic nonunion compared with ERN. Especially for non-isthmic femoral shaft atrophic nonunions, AAP provided a significantly higher union rate and significantly shorter operating time. BioMed Central 2019-03-25 /pmc/articles/PMC6434807/ /pubmed/30909909 http://dx.doi.org/10.1186/s12891-019-2514-3 Text en © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Lai, Po-Ju
Hsu, Yung-Heng
Chou, Ying-Chao
Yeh, Wen-Ling
Ueng, Steve W. N.
Yu, Yi-Hsun
Augmentative antirotational plating provided a significantly higher union rate than exchanging reamed nailing in treatment for femoral shaft aseptic atrophic nonunion - retrospective cohort study
title Augmentative antirotational plating provided a significantly higher union rate than exchanging reamed nailing in treatment for femoral shaft aseptic atrophic nonunion - retrospective cohort study
title_full Augmentative antirotational plating provided a significantly higher union rate than exchanging reamed nailing in treatment for femoral shaft aseptic atrophic nonunion - retrospective cohort study
title_fullStr Augmentative antirotational plating provided a significantly higher union rate than exchanging reamed nailing in treatment for femoral shaft aseptic atrophic nonunion - retrospective cohort study
title_full_unstemmed Augmentative antirotational plating provided a significantly higher union rate than exchanging reamed nailing in treatment for femoral shaft aseptic atrophic nonunion - retrospective cohort study
title_short Augmentative antirotational plating provided a significantly higher union rate than exchanging reamed nailing in treatment for femoral shaft aseptic atrophic nonunion - retrospective cohort study
title_sort augmentative antirotational plating provided a significantly higher union rate than exchanging reamed nailing in treatment for femoral shaft aseptic atrophic nonunion - retrospective cohort study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6434807/
https://www.ncbi.nlm.nih.gov/pubmed/30909909
http://dx.doi.org/10.1186/s12891-019-2514-3
work_keys_str_mv AT laipoju augmentativeantirotationalplatingprovidedasignificantlyhigherunionratethanexchangingreamednailingintreatmentforfemoralshaftasepticatrophicnonunionretrospectivecohortstudy
AT hsuyungheng augmentativeantirotationalplatingprovidedasignificantlyhigherunionratethanexchangingreamednailingintreatmentforfemoralshaftasepticatrophicnonunionretrospectivecohortstudy
AT chouyingchao augmentativeantirotationalplatingprovidedasignificantlyhigherunionratethanexchangingreamednailingintreatmentforfemoralshaftasepticatrophicnonunionretrospectivecohortstudy
AT yehwenling augmentativeantirotationalplatingprovidedasignificantlyhigherunionratethanexchangingreamednailingintreatmentforfemoralshaftasepticatrophicnonunionretrospectivecohortstudy
AT uengstevewn augmentativeantirotationalplatingprovidedasignificantlyhigherunionratethanexchangingreamednailingintreatmentforfemoralshaftasepticatrophicnonunionretrospectivecohortstudy
AT yuyihsun augmentativeantirotationalplatingprovidedasignificantlyhigherunionratethanexchangingreamednailingintreatmentforfemoralshaftasepticatrophicnonunionretrospectivecohortstudy