Cargando…
Dispersive white light continuum single Z-scan for rapid determination of degenerate two-photon absorption spectra
We present an experimental technique to determine the degenerate two-photon absorption (2PA) spectra by performing a single Z-scan using a high-spectral-irradiance white light continuum (WLC) generated by a hollow core fiber. The hollow fiber was filled with Argon (Ar) gas at a pressure of 0.6 bar a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6435023/ https://www.ncbi.nlm.nih.gov/pubmed/30996529 http://dx.doi.org/10.1007/s00340-018-7011-0 |
_version_ | 1783406584838225920 |
---|---|
author | Ajami, Aliasghar Husinsky, Wolfgang Ovsianikov, Aleksandr Liska, Robert |
author_facet | Ajami, Aliasghar Husinsky, Wolfgang Ovsianikov, Aleksandr Liska, Robert |
author_sort | Ajami, Aliasghar |
collection | PubMed |
description | We present an experimental technique to determine the degenerate two-photon absorption (2PA) spectra by performing a single Z-scan using a high-spectral-irradiance white light continuum (WLC) generated by a hollow core fiber. The hollow fiber was filled with Argon (Ar) gas at a pressure of 0.6 bar and was pumped with 500 mJ, 30 fs, and 800 nm pulses. The broadband WLC pulses with 350 nm bandwidth in the range of 600–950 nm were compressed to sub-8 fs pulses. To characterize and interpret the data obtained from this method, the spectral, temporal and spatial characteristics of the WLC were first analyzed. The WLC emerging from the compressor was dispersed using a prism pair and then focused into the sample by a cylindrical lens. Since different spectral components are spatially separated, any part of the sample in the beam cross section is irradiated with almost single wavelength pulses leading to only a degenerate 2PA process. The nonlinear transmittance was then measured by a charge-coupled-device (CCD) line camera as a function of the sample position while the sample was moved along the beam direction by a motorized translation stage. In this way the Z-scans at different wavelengths in the WLC spectral range can be measured and thus the wavelength-resolved degenerate 2PA spectra can be obtained by performing a single scan using dispersive WLC. This method was verified on a well-characterized dye Rhodamine B and yield a reasonable agreement with the data found in the literature. We used this method to determine the 2PA spectra of some two-photon initiators (2PIs) developed for two-photon polymerization (2PP) based 3D micro-structuring. |
format | Online Article Text |
id | pubmed-6435023 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-64350232019-04-15 Dispersive white light continuum single Z-scan for rapid determination of degenerate two-photon absorption spectra Ajami, Aliasghar Husinsky, Wolfgang Ovsianikov, Aleksandr Liska, Robert Appl Phys B Article We present an experimental technique to determine the degenerate two-photon absorption (2PA) spectra by performing a single Z-scan using a high-spectral-irradiance white light continuum (WLC) generated by a hollow core fiber. The hollow fiber was filled with Argon (Ar) gas at a pressure of 0.6 bar and was pumped with 500 mJ, 30 fs, and 800 nm pulses. The broadband WLC pulses with 350 nm bandwidth in the range of 600–950 nm were compressed to sub-8 fs pulses. To characterize and interpret the data obtained from this method, the spectral, temporal and spatial characteristics of the WLC were first analyzed. The WLC emerging from the compressor was dispersed using a prism pair and then focused into the sample by a cylindrical lens. Since different spectral components are spatially separated, any part of the sample in the beam cross section is irradiated with almost single wavelength pulses leading to only a degenerate 2PA process. The nonlinear transmittance was then measured by a charge-coupled-device (CCD) line camera as a function of the sample position while the sample was moved along the beam direction by a motorized translation stage. In this way the Z-scans at different wavelengths in the WLC spectral range can be measured and thus the wavelength-resolved degenerate 2PA spectra can be obtained by performing a single scan using dispersive WLC. This method was verified on a well-characterized dye Rhodamine B and yield a reasonable agreement with the data found in the literature. We used this method to determine the 2PA spectra of some two-photon initiators (2PIs) developed for two-photon polymerization (2PP) based 3D micro-structuring. Springer Berlin Heidelberg 2018-06-22 2018 /pmc/articles/PMC6435023/ /pubmed/30996529 http://dx.doi.org/10.1007/s00340-018-7011-0 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Article Ajami, Aliasghar Husinsky, Wolfgang Ovsianikov, Aleksandr Liska, Robert Dispersive white light continuum single Z-scan for rapid determination of degenerate two-photon absorption spectra |
title | Dispersive white light continuum single Z-scan for rapid determination of degenerate two-photon absorption spectra |
title_full | Dispersive white light continuum single Z-scan for rapid determination of degenerate two-photon absorption spectra |
title_fullStr | Dispersive white light continuum single Z-scan for rapid determination of degenerate two-photon absorption spectra |
title_full_unstemmed | Dispersive white light continuum single Z-scan for rapid determination of degenerate two-photon absorption spectra |
title_short | Dispersive white light continuum single Z-scan for rapid determination of degenerate two-photon absorption spectra |
title_sort | dispersive white light continuum single z-scan for rapid determination of degenerate two-photon absorption spectra |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6435023/ https://www.ncbi.nlm.nih.gov/pubmed/30996529 http://dx.doi.org/10.1007/s00340-018-7011-0 |
work_keys_str_mv | AT ajamialiasghar dispersivewhitelightcontinuumsinglezscanforrapiddeterminationofdegeneratetwophotonabsorptionspectra AT husinskywolfgang dispersivewhitelightcontinuumsinglezscanforrapiddeterminationofdegeneratetwophotonabsorptionspectra AT ovsianikovaleksandr dispersivewhitelightcontinuumsinglezscanforrapiddeterminationofdegeneratetwophotonabsorptionspectra AT liskarobert dispersivewhitelightcontinuumsinglezscanforrapiddeterminationofdegeneratetwophotonabsorptionspectra |