Cargando…

Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty

PURPOSE: The purpose of the present study was to compare patient-specific instrumentation (PSI) with standard instrumentation (SI) in patients undergoing total knee arthroplasty (TKA). PSI is hypothesized to have advantages with respect to component alignment; number of outliers (defined as alignmen...

Descripción completa

Detalles Bibliográficos
Autores principales: Gong, Song, Xu, Weihua, Wang, Ruoyu, Wang, Zijian, Wang, Bo, Han, Lizhi, Chen, Guo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6435625/
https://www.ncbi.nlm.nih.gov/pubmed/30377714
http://dx.doi.org/10.1007/s00167-018-5256-0
_version_ 1783406673541464064
author Gong, Song
Xu, Weihua
Wang, Ruoyu
Wang, Zijian
Wang, Bo
Han, Lizhi
Chen, Guo
author_facet Gong, Song
Xu, Weihua
Wang, Ruoyu
Wang, Zijian
Wang, Bo
Han, Lizhi
Chen, Guo
author_sort Gong, Song
collection PubMed
description PURPOSE: The purpose of the present study was to compare patient-specific instrumentation (PSI) with standard instrumentation (SI) in patients undergoing total knee arthroplasty (TKA). PSI is hypothesized to have advantages with respect to component alignment; number of outliers (defined as alignment > 3° from the target alignment); operative time; perioperative blood loss; and length of hospital stay. This new surgical technique is expected to exhibit superior performance. METHODS: A total of 23 randomized controlled trials (RCTs) involving 2058 knees that compared the clinical outcomes of TKA between PSI and SI were included in the present analysis; these RCTs were identified via a literature search of the PubMed, Embase, and Cochrane Library databases through March 1, 2018. The outcomes of interest included coronal, sagittal and axial component alignment (presented as the angle of deviation from the transcondylar line); number of outliers; operative time; perioperative blood loss; and length of hospital stay. RESULTS: There was a significant difference in postoperative femoral axial alignment between PSI and SI patients (95% CI − 0.71 to − 0.21, p = 0.0004, I(2) = 48%). PSI resulted in approximately 0.4° less deviation from the transcondylar line than SI. Based on our results, PSI reduced operative time by a mean of 7 min compared with SI (95% CI − 10.95 to − 3.75, p < 0.0001, I(2) = 78%). According to the included literature, PSI reduced perioperative blood loss by approximately 90 ml compared with SI (95% CI − 146.65 to − 20.18, p = 0.01, I(2) = 74%). We did not find any differences between PSI and SI with respect to any other parameters. CONCLUSIONS: PSI has advantages in axial alignment of the femoral component, operative time, and perioperative blood loss relative to SI. No significant differences were found between PSI and SI with respect to alignment of the remaining components, number of outliers, or length of hospital stay. LEVEL OF EVIDENCE: Therapeutic study (systematic review and meta-analysis), Level I.
format Online
Article
Text
id pubmed-6435625
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-64356252019-04-15 Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty Gong, Song Xu, Weihua Wang, Ruoyu Wang, Zijian Wang, Bo Han, Lizhi Chen, Guo Knee Surg Sports Traumatol Arthrosc Knee PURPOSE: The purpose of the present study was to compare patient-specific instrumentation (PSI) with standard instrumentation (SI) in patients undergoing total knee arthroplasty (TKA). PSI is hypothesized to have advantages with respect to component alignment; number of outliers (defined as alignment > 3° from the target alignment); operative time; perioperative blood loss; and length of hospital stay. This new surgical technique is expected to exhibit superior performance. METHODS: A total of 23 randomized controlled trials (RCTs) involving 2058 knees that compared the clinical outcomes of TKA between PSI and SI were included in the present analysis; these RCTs were identified via a literature search of the PubMed, Embase, and Cochrane Library databases through March 1, 2018. The outcomes of interest included coronal, sagittal and axial component alignment (presented as the angle of deviation from the transcondylar line); number of outliers; operative time; perioperative blood loss; and length of hospital stay. RESULTS: There was a significant difference in postoperative femoral axial alignment between PSI and SI patients (95% CI − 0.71 to − 0.21, p = 0.0004, I(2) = 48%). PSI resulted in approximately 0.4° less deviation from the transcondylar line than SI. Based on our results, PSI reduced operative time by a mean of 7 min compared with SI (95% CI − 10.95 to − 3.75, p < 0.0001, I(2) = 78%). According to the included literature, PSI reduced perioperative blood loss by approximately 90 ml compared with SI (95% CI − 146.65 to − 20.18, p = 0.01, I(2) = 74%). We did not find any differences between PSI and SI with respect to any other parameters. CONCLUSIONS: PSI has advantages in axial alignment of the femoral component, operative time, and perioperative blood loss relative to SI. No significant differences were found between PSI and SI with respect to alignment of the remaining components, number of outliers, or length of hospital stay. LEVEL OF EVIDENCE: Therapeutic study (systematic review and meta-analysis), Level I. Springer Berlin Heidelberg 2018-10-30 2019 /pmc/articles/PMC6435625/ /pubmed/30377714 http://dx.doi.org/10.1007/s00167-018-5256-0 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Knee
Gong, Song
Xu, Weihua
Wang, Ruoyu
Wang, Zijian
Wang, Bo
Han, Lizhi
Chen, Guo
Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty
title Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty
title_full Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty
title_fullStr Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty
title_full_unstemmed Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty
title_short Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty
title_sort patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6435625/
https://www.ncbi.nlm.nih.gov/pubmed/30377714
http://dx.doi.org/10.1007/s00167-018-5256-0
work_keys_str_mv AT gongsong patientspecificinstrumentationimprovedaxialalignmentofthefemoralcomponentoperativetimeandperioperativebloodlossaftertotalkneearthroplasty
AT xuweihua patientspecificinstrumentationimprovedaxialalignmentofthefemoralcomponentoperativetimeandperioperativebloodlossaftertotalkneearthroplasty
AT wangruoyu patientspecificinstrumentationimprovedaxialalignmentofthefemoralcomponentoperativetimeandperioperativebloodlossaftertotalkneearthroplasty
AT wangzijian patientspecificinstrumentationimprovedaxialalignmentofthefemoralcomponentoperativetimeandperioperativebloodlossaftertotalkneearthroplasty
AT wangbo patientspecificinstrumentationimprovedaxialalignmentofthefemoralcomponentoperativetimeandperioperativebloodlossaftertotalkneearthroplasty
AT hanlizhi patientspecificinstrumentationimprovedaxialalignmentofthefemoralcomponentoperativetimeandperioperativebloodlossaftertotalkneearthroplasty
AT chenguo patientspecificinstrumentationimprovedaxialalignmentofthefemoralcomponentoperativetimeandperioperativebloodlossaftertotalkneearthroplasty