PURPOSE: The purpose of this study is to report normative data and predict thresholds for a rapid test of spatial release from masking for speech perception. The test is easily administered and has good repeatability, with the potential to be used in clinics and laboratories. Normative functions wer...

Descripción completa

Detalles Bibliográficos
Autores principales: Jakien, Kasey M., Gallun, Frederick J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Speech-Language-Hearing Association 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6436452/
https://www.ncbi.nlm.nih.gov/pubmed/30458523
http://dx.doi.org/10.1044/2018_AJA-17-0069
_version_ 1783406818185183232
author Jakien, Kasey M.
Gallun, Frederick J.
author_facet Jakien, Kasey M.
Gallun, Frederick J.
author_sort Jakien, Kasey M.
collection PubMed
description PURPOSE: The purpose of this study is to report normative data and predict thresholds for a rapid test of spatial release from masking for speech perception. The test is easily administered and has good repeatability, with the potential to be used in clinics and laboratories. Normative functions were generated for adults varying in age and amounts of hearing loss. METHOD: The test of spatial release presents a virtual auditory scene over headphones with 2 conditions: colocated (with target and maskers at 0°) and spatially separated (with target at 0° and maskers at ± 45°). Listener thresholds are determined as target-to-masker ratios, and spatial release from masking (SRM) is determined as the difference between the colocated condition and spatially separated condition. Multiple linear regression was used to fit the data from 82 adults 18–80 years of age with normal to moderate hearing loss (0–40 dB HL pure-tone average [PTA]). The regression equations were then used to generate normative functions that relate age (in years) and hearing thresholds (as PTA) to target-to-masker ratios and SRM. RESULTS: Normative functions were able to predict thresholds with an error of less than 3.5 dB in all conditions. In the colocated condition, the function included only age as a predictive parameter, whereas in the spatially separated condition, both age and PTA were included as parameters. For SRM, PTA was the only significant predictor. Different functions were generated for the 1st run, the 2nd run, and the average of the 2 runs. All 3 functions were largely similar in form, with the smallest error being associated with the function on the basis of the average of 2 runs. CONCLUSION: With the normative functions generated from this data set, it would be possible for a researcher or clinician to interpret data from a small number of participants or even a single patient without having to first collect data from a control group, substantially reducing the time and resources needed. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.7080878
format Online
Article
Text
id pubmed-6436452
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher American Speech-Language-Hearing Association
record_format MEDLINE/PubMed
spelling pubmed-64364522019-06-01 Normative Data for a Rapid, Automated Test of Spatial Release From Masking Jakien, Kasey M. Gallun, Frederick J. Am J Audiol Research Articles PURPOSE: The purpose of this study is to report normative data and predict thresholds for a rapid test of spatial release from masking for speech perception. The test is easily administered and has good repeatability, with the potential to be used in clinics and laboratories. Normative functions were generated for adults varying in age and amounts of hearing loss. METHOD: The test of spatial release presents a virtual auditory scene over headphones with 2 conditions: colocated (with target and maskers at 0°) and spatially separated (with target at 0° and maskers at ± 45°). Listener thresholds are determined as target-to-masker ratios, and spatial release from masking (SRM) is determined as the difference between the colocated condition and spatially separated condition. Multiple linear regression was used to fit the data from 82 adults 18–80 years of age with normal to moderate hearing loss (0–40 dB HL pure-tone average [PTA]). The regression equations were then used to generate normative functions that relate age (in years) and hearing thresholds (as PTA) to target-to-masker ratios and SRM. RESULTS: Normative functions were able to predict thresholds with an error of less than 3.5 dB in all conditions. In the colocated condition, the function included only age as a predictive parameter, whereas in the spatially separated condition, both age and PTA were included as parameters. For SRM, PTA was the only significant predictor. Different functions were generated for the 1st run, the 2nd run, and the average of the 2 runs. All 3 functions were largely similar in form, with the smallest error being associated with the function on the basis of the average of 2 runs. CONCLUSION: With the normative functions generated from this data set, it would be possible for a researcher or clinician to interpret data from a small number of participants or even a single patient without having to first collect data from a control group, substantially reducing the time and resources needed. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.7080878 American Speech-Language-Hearing Association 2018-12 2018-12-06 /pmc/articles/PMC6436452/ /pubmed/30458523 http://dx.doi.org/10.1044/2018_AJA-17-0069 Text en Copyright © 2018 The Authors http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Articles
Jakien, Kasey M.
Gallun, Frederick J.
Normative Data for a Rapid, Automated Test of Spatial Release From Masking
title Normative Data for a Rapid, Automated Test of Spatial Release From Masking
title_full Normative Data for a Rapid, Automated Test of Spatial Release From Masking
title_fullStr Normative Data for a Rapid, Automated Test of Spatial Release From Masking
title_full_unstemmed Normative Data for a Rapid, Automated Test of Spatial Release From Masking
title_short Normative Data for a Rapid, Automated Test of Spatial Release From Masking
title_sort normative data for a rapid, automated test of spatial release from masking
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6436452/
https://www.ncbi.nlm.nih.gov/pubmed/30458523
http://dx.doi.org/10.1044/2018_AJA-17-0069
work_keys_str_mv AT jakienkaseym normativedataforarapidautomatedtestofspatialreleasefrommasking
AT gallunfrederickj normativedataforarapidautomatedtestofspatialreleasefrommasking