Cargando…
Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral Valve Replacement: Meta-Analysis of 10,239 Patients
OBJECTIVE: This study sought to evaluate the impact of prosthesis-patient mismatch on the risk of perioperative and long-term mortality after mitral valve replacement. METHODS: Databases were researched for studies published until December 2018. Main outcomes of interest were perioperative and 10-ye...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Cirurgia Cardiovascular
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6436788/ https://www.ncbi.nlm.nih.gov/pubmed/30916131 http://dx.doi.org/10.21470/1678-9741-2019-0069 |
_version_ | 1783406862475984896 |
---|---|
author | Sá, Michel Pompeu Barros Oliveira Cavalcanti, Luiz Rafael Pereira Rayol, Sérgio da Costa Diniz, Roberto Gouvea Silva Menezes, Alexandre Motta Clavel, Marie-Annick Pibarot, Philippe Lima, Ricardo Carvalho |
author_facet | Sá, Michel Pompeu Barros Oliveira Cavalcanti, Luiz Rafael Pereira Rayol, Sérgio da Costa Diniz, Roberto Gouvea Silva Menezes, Alexandre Motta Clavel, Marie-Annick Pibarot, Philippe Lima, Ricardo Carvalho |
author_sort | Sá, Michel Pompeu Barros Oliveira |
collection | PubMed |
description | OBJECTIVE: This study sought to evaluate the impact of prosthesis-patient mismatch on the risk of perioperative and long-term mortality after mitral valve replacement. METHODS: Databases were researched for studies published until December 2018. Main outcomes of interest were perioperative and 10-year mortality and echocardiographic parameters. RESULTS: The research yielded 2,985 studies for inclusion. Of these, 16 articles were analyzed, and their data extracted. The total number of patients included was 10,239, who underwent mitral valve replacement. The incidence of prosthesis-patient mismatch after mitral valve replacement was 53.7% (5,499 with prosthesis-patient mismatch and 4,740 without prosthesis-patient mismatch). Perioperative (OR 1.519; 95%CI 1.194-1.931, P<0.001) and 10-year (OR 1.515; 95%CI 1.280-1.795, P<0.001) mortality was increased in patients with prosthesis-patient mismatch. Patients with prosthesis-patient mismatch after mitral valve replacement had higher systolic pulmonary artery pressure and transprosthethic gradient and lower indexed effective orifice area and left ventricle ejection fraction. CONCLUSION: Prosthesis-patient mismatch increases perioperative and long-term mortality. Prosthesis-patient mismatch is also associated with pulmonary hypertension and depressed left ventricle systolic function. The findings of this study support the implementation of surgical strategies to prevent prosthesis-patient mismatch in order to decrease mortality rates. |
format | Online Article Text |
id | pubmed-6436788 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Sociedade Brasileira de Cirurgia Cardiovascular |
record_format | MEDLINE/PubMed |
spelling | pubmed-64367882019-04-02 Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral Valve Replacement: Meta-Analysis of 10,239 Patients Sá, Michel Pompeu Barros Oliveira Cavalcanti, Luiz Rafael Pereira Rayol, Sérgio da Costa Diniz, Roberto Gouvea Silva Menezes, Alexandre Motta Clavel, Marie-Annick Pibarot, Philippe Lima, Ricardo Carvalho Braz J Cardiovasc Surg Original Article OBJECTIVE: This study sought to evaluate the impact of prosthesis-patient mismatch on the risk of perioperative and long-term mortality after mitral valve replacement. METHODS: Databases were researched for studies published until December 2018. Main outcomes of interest were perioperative and 10-year mortality and echocardiographic parameters. RESULTS: The research yielded 2,985 studies for inclusion. Of these, 16 articles were analyzed, and their data extracted. The total number of patients included was 10,239, who underwent mitral valve replacement. The incidence of prosthesis-patient mismatch after mitral valve replacement was 53.7% (5,499 with prosthesis-patient mismatch and 4,740 without prosthesis-patient mismatch). Perioperative (OR 1.519; 95%CI 1.194-1.931, P<0.001) and 10-year (OR 1.515; 95%CI 1.280-1.795, P<0.001) mortality was increased in patients with prosthesis-patient mismatch. Patients with prosthesis-patient mismatch after mitral valve replacement had higher systolic pulmonary artery pressure and transprosthethic gradient and lower indexed effective orifice area and left ventricle ejection fraction. CONCLUSION: Prosthesis-patient mismatch increases perioperative and long-term mortality. Prosthesis-patient mismatch is also associated with pulmonary hypertension and depressed left ventricle systolic function. The findings of this study support the implementation of surgical strategies to prevent prosthesis-patient mismatch in order to decrease mortality rates. Sociedade Brasileira de Cirurgia Cardiovascular 2019 /pmc/articles/PMC6436788/ /pubmed/30916131 http://dx.doi.org/10.21470/1678-9741-2019-0069 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Sá, Michel Pompeu Barros Oliveira Cavalcanti, Luiz Rafael Pereira Rayol, Sérgio da Costa Diniz, Roberto Gouvea Silva Menezes, Alexandre Motta Clavel, Marie-Annick Pibarot, Philippe Lima, Ricardo Carvalho Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral Valve Replacement: Meta-Analysis of 10,239 Patients |
title | Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral
Valve Replacement: Meta-Analysis of 10,239 Patients |
title_full | Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral
Valve Replacement: Meta-Analysis of 10,239 Patients |
title_fullStr | Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral
Valve Replacement: Meta-Analysis of 10,239 Patients |
title_full_unstemmed | Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral
Valve Replacement: Meta-Analysis of 10,239 Patients |
title_short | Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral
Valve Replacement: Meta-Analysis of 10,239 Patients |
title_sort | prosthesis-patient mismatch negatively affects outcomes after mitral
valve replacement: meta-analysis of 10,239 patients |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6436788/ https://www.ncbi.nlm.nih.gov/pubmed/30916131 http://dx.doi.org/10.21470/1678-9741-2019-0069 |
work_keys_str_mv | AT samichelpompeubarrosoliveira prosthesispatientmismatchnegativelyaffectsoutcomesaftermitralvalvereplacementmetaanalysisof10239patients AT cavalcantiluizrafaelpereira prosthesispatientmismatchnegativelyaffectsoutcomesaftermitralvalvereplacementmetaanalysisof10239patients AT rayolsergiodacosta prosthesispatientmismatchnegativelyaffectsoutcomesaftermitralvalvereplacementmetaanalysisof10239patients AT dinizrobertogouveasilva prosthesispatientmismatchnegativelyaffectsoutcomesaftermitralvalvereplacementmetaanalysisof10239patients AT menezesalexandremotta prosthesispatientmismatchnegativelyaffectsoutcomesaftermitralvalvereplacementmetaanalysisof10239patients AT clavelmarieannick prosthesispatientmismatchnegativelyaffectsoutcomesaftermitralvalvereplacementmetaanalysisof10239patients AT pibarotphilippe prosthesispatientmismatchnegativelyaffectsoutcomesaftermitralvalvereplacementmetaanalysisof10239patients AT limaricardocarvalho prosthesispatientmismatchnegativelyaffectsoutcomesaftermitralvalvereplacementmetaanalysisof10239patients |