Cargando…

EADSG Guidelines: Insulin Storage and Optimisation of Injection Technique in Diabetes Management

To date, insulin therapy remains the cornerstone of diabetes management; but the art of injecting insulin is still poorly understood in many health facilities. To address this gap, the Forum for Injection Technique and Therapy Expert Recommendations (FITTER) published recommendations on injection te...

Descripción completa

Detalles Bibliográficos
Autores principales: Bahendeka, Silver, Kaushik, Ramaiya, Swai, Andrew Babu, Otieno, Fredrick, Bajaj, Sarita, Kalra, Sanjay, Bavuma, Charlotte M., Karigire, Claudine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6437255/
https://www.ncbi.nlm.nih.gov/pubmed/30815830
http://dx.doi.org/10.1007/s13300-019-0574-x
_version_ 1783406928445046784
author Bahendeka, Silver
Kaushik, Ramaiya
Swai, Andrew Babu
Otieno, Fredrick
Bajaj, Sarita
Kalra, Sanjay
Bavuma, Charlotte M.
Karigire, Claudine
author_facet Bahendeka, Silver
Kaushik, Ramaiya
Swai, Andrew Babu
Otieno, Fredrick
Bajaj, Sarita
Kalra, Sanjay
Bavuma, Charlotte M.
Karigire, Claudine
author_sort Bahendeka, Silver
collection PubMed
description To date, insulin therapy remains the cornerstone of diabetes management; but the art of injecting insulin is still poorly understood in many health facilities. To address this gap, the Forum for Injection Technique and Therapy Expert Recommendations (FITTER) published recommendations on injection technique after a workshop held in Rome, Italy in 2015. These recommendations are generally applicable to the majority of patients on insulin therapy, athough they do not explore alternative details that may be suitable for low- and middle-income countries. The East Africa Diabetes Study Group sought to address this gap, and furthermore to seek consensus on some of the contextual issues pertaining to insulin therapy within the East African region, specifically focusing on scarcity of resources and its adverse effect on the quality of care. A meeting of health care professionals, experts in diabetes management and patients using insulin, was convened in Kigali, Rwanda on 11 March 2018, and the following recommendations were made: (1) insulin should be transported safely, without undue shaking and exposure to high (> 32 °C) temperature environments. (2) Insulin should not be transported below 0 °C. (3) If insulin is to be stored at home for over 2 months, it should be stored at the recommended temperature of 2–8 °C. (4) Appropriate instructions should be given to patients while dispensing insulin. (5) Insulin in use should be kept at room temperature and should never be kept immersed under water. Immersing insulin under water after the vial has been pierced carries a high risk of contamination, leading to loss of potency and likelihood of causing injection abscesses. (6) The shortest available needles (4 mm for pen and 6 mm for insulin syringe) should be preferred for all patients. (7) In routine care, intramuscular injections should be avoided, especially with long-acting insulins, as it may result in severe hypoglycaemia. (8) The practice of slanting the needle excessively should be avoided as it results in sub-epidermal injection of insulin which leads to poor absorption and may cause “tattooing” of the skin and scarring. (9) In patients presenting in a wasted state, with “paper-like skin”, injections should, if possible, be initiated with pen injection devices, so as to utilise the 4-mm needle without lifting a skin fold (pinching the skin); otherwise lifting of a skin fold is required, if longer needles are utilised. (10) Reuse of needles and syringes is not recommended. However, as the reuse of syringes and needles is practiced for various reasons, and by many patients, individuals should not be given alarming messages; and usage should be limited to discarding when injections become more painful; but at any rate not to exceed reusing a needle more than 5 times. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s13300-019-0574-x) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6437255
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Healthcare
record_format MEDLINE/PubMed
spelling pubmed-64372552019-04-15 EADSG Guidelines: Insulin Storage and Optimisation of Injection Technique in Diabetes Management Bahendeka, Silver Kaushik, Ramaiya Swai, Andrew Babu Otieno, Fredrick Bajaj, Sarita Kalra, Sanjay Bavuma, Charlotte M. Karigire, Claudine Diabetes Ther Guidelines To date, insulin therapy remains the cornerstone of diabetes management; but the art of injecting insulin is still poorly understood in many health facilities. To address this gap, the Forum for Injection Technique and Therapy Expert Recommendations (FITTER) published recommendations on injection technique after a workshop held in Rome, Italy in 2015. These recommendations are generally applicable to the majority of patients on insulin therapy, athough they do not explore alternative details that may be suitable for low- and middle-income countries. The East Africa Diabetes Study Group sought to address this gap, and furthermore to seek consensus on some of the contextual issues pertaining to insulin therapy within the East African region, specifically focusing on scarcity of resources and its adverse effect on the quality of care. A meeting of health care professionals, experts in diabetes management and patients using insulin, was convened in Kigali, Rwanda on 11 March 2018, and the following recommendations were made: (1) insulin should be transported safely, without undue shaking and exposure to high (> 32 °C) temperature environments. (2) Insulin should not be transported below 0 °C. (3) If insulin is to be stored at home for over 2 months, it should be stored at the recommended temperature of 2–8 °C. (4) Appropriate instructions should be given to patients while dispensing insulin. (5) Insulin in use should be kept at room temperature and should never be kept immersed under water. Immersing insulin under water after the vial has been pierced carries a high risk of contamination, leading to loss of potency and likelihood of causing injection abscesses. (6) The shortest available needles (4 mm for pen and 6 mm for insulin syringe) should be preferred for all patients. (7) In routine care, intramuscular injections should be avoided, especially with long-acting insulins, as it may result in severe hypoglycaemia. (8) The practice of slanting the needle excessively should be avoided as it results in sub-epidermal injection of insulin which leads to poor absorption and may cause “tattooing” of the skin and scarring. (9) In patients presenting in a wasted state, with “paper-like skin”, injections should, if possible, be initiated with pen injection devices, so as to utilise the 4-mm needle without lifting a skin fold (pinching the skin); otherwise lifting of a skin fold is required, if longer needles are utilised. (10) Reuse of needles and syringes is not recommended. However, as the reuse of syringes and needles is practiced for various reasons, and by many patients, individuals should not be given alarming messages; and usage should be limited to discarding when injections become more painful; but at any rate not to exceed reusing a needle more than 5 times. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s13300-019-0574-x) contains supplementary material, which is available to authorized users. Springer Healthcare 2019-02-27 2019-04 /pmc/articles/PMC6437255/ /pubmed/30815830 http://dx.doi.org/10.1007/s13300-019-0574-x Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Guidelines
Bahendeka, Silver
Kaushik, Ramaiya
Swai, Andrew Babu
Otieno, Fredrick
Bajaj, Sarita
Kalra, Sanjay
Bavuma, Charlotte M.
Karigire, Claudine
EADSG Guidelines: Insulin Storage and Optimisation of Injection Technique in Diabetes Management
title EADSG Guidelines: Insulin Storage and Optimisation of Injection Technique in Diabetes Management
title_full EADSG Guidelines: Insulin Storage and Optimisation of Injection Technique in Diabetes Management
title_fullStr EADSG Guidelines: Insulin Storage and Optimisation of Injection Technique in Diabetes Management
title_full_unstemmed EADSG Guidelines: Insulin Storage and Optimisation of Injection Technique in Diabetes Management
title_short EADSG Guidelines: Insulin Storage and Optimisation of Injection Technique in Diabetes Management
title_sort eadsg guidelines: insulin storage and optimisation of injection technique in diabetes management
topic Guidelines
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6437255/
https://www.ncbi.nlm.nih.gov/pubmed/30815830
http://dx.doi.org/10.1007/s13300-019-0574-x
work_keys_str_mv AT bahendekasilver eadsgguidelinesinsulinstorageandoptimisationofinjectiontechniqueindiabetesmanagement
AT kaushikramaiya eadsgguidelinesinsulinstorageandoptimisationofinjectiontechniqueindiabetesmanagement
AT swaiandrewbabu eadsgguidelinesinsulinstorageandoptimisationofinjectiontechniqueindiabetesmanagement
AT otienofredrick eadsgguidelinesinsulinstorageandoptimisationofinjectiontechniqueindiabetesmanagement
AT bajajsarita eadsgguidelinesinsulinstorageandoptimisationofinjectiontechniqueindiabetesmanagement
AT kalrasanjay eadsgguidelinesinsulinstorageandoptimisationofinjectiontechniqueindiabetesmanagement
AT bavumacharlottem eadsgguidelinesinsulinstorageandoptimisationofinjectiontechniqueindiabetesmanagement
AT karigireclaudine eadsgguidelinesinsulinstorageandoptimisationofinjectiontechniqueindiabetesmanagement