Cargando…
Optimization of Semiautomated Calibration Algorithm of Multichannel Electrotactile Feedback for Myoelectric Hand Prosthesis
The main drawback of the commercially available myoelectric hand prostheses is the absence of somatosensory feedback. We recently developed a feedback interface for multiple degrees of freedom myoelectric prosthesis that allows proprioceptive and sensory information (i.e., grasping force) to be tran...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6437744/ https://www.ncbi.nlm.nih.gov/pubmed/31001360 http://dx.doi.org/10.1155/2019/9298758 |
_version_ | 1783406985364897792 |
---|---|
author | Isaković, Milica Malešević, Jovana Keller, Thierry Kostić, Miloš Štrbac, Matija |
author_facet | Isaković, Milica Malešević, Jovana Keller, Thierry Kostić, Miloš Štrbac, Matija |
author_sort | Isaković, Milica |
collection | PubMed |
description | The main drawback of the commercially available myoelectric hand prostheses is the absence of somatosensory feedback. We recently developed a feedback interface for multiple degrees of freedom myoelectric prosthesis that allows proprioceptive and sensory information (i.e., grasping force) to be transmitted to the wearer instantaneously. High information bandwidth is achieved through intelligent control of spatiotemporal distribution of electrical pulses over a custom-designed electrode array. As electrotactile sensations are location-dependent and the developed interface requires that electrical stimuli are perceived to be of the same intensity on all locations, a calibration procedure is of high importance. The aim of this study was to gain more insight into the calibration procedure and optimize this process by leveraging a priori knowledge. For this purpose, we conducted a study with 9 able-bodied subjects performing 10 sessions of the array electrode calibration. Based on the collected data, we optimized and simplified the calibration procedure by adapting the initial (baseline) amplitude values in the calibration algorithm. The results suggest there is an individual pattern of stimulation amplitudes across 16 electrode pads for each subject, which is not affected by the initial amplitudes. Moreover, the number of user actions performed and the time needed for the calibration procedure are significantly reduced by the proposed methodology. |
format | Online Article Text |
id | pubmed-6437744 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-64377442019-04-18 Optimization of Semiautomated Calibration Algorithm of Multichannel Electrotactile Feedback for Myoelectric Hand Prosthesis Isaković, Milica Malešević, Jovana Keller, Thierry Kostić, Miloš Štrbac, Matija Appl Bionics Biomech Research Article The main drawback of the commercially available myoelectric hand prostheses is the absence of somatosensory feedback. We recently developed a feedback interface for multiple degrees of freedom myoelectric prosthesis that allows proprioceptive and sensory information (i.e., grasping force) to be transmitted to the wearer instantaneously. High information bandwidth is achieved through intelligent control of spatiotemporal distribution of electrical pulses over a custom-designed electrode array. As electrotactile sensations are location-dependent and the developed interface requires that electrical stimuli are perceived to be of the same intensity on all locations, a calibration procedure is of high importance. The aim of this study was to gain more insight into the calibration procedure and optimize this process by leveraging a priori knowledge. For this purpose, we conducted a study with 9 able-bodied subjects performing 10 sessions of the array electrode calibration. Based on the collected data, we optimized and simplified the calibration procedure by adapting the initial (baseline) amplitude values in the calibration algorithm. The results suggest there is an individual pattern of stimulation amplitudes across 16 electrode pads for each subject, which is not affected by the initial amplitudes. Moreover, the number of user actions performed and the time needed for the calibration procedure are significantly reduced by the proposed methodology. Hindawi 2019-03-14 /pmc/articles/PMC6437744/ /pubmed/31001360 http://dx.doi.org/10.1155/2019/9298758 Text en Copyright © 2019 Milica Isaković et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Isaković, Milica Malešević, Jovana Keller, Thierry Kostić, Miloš Štrbac, Matija Optimization of Semiautomated Calibration Algorithm of Multichannel Electrotactile Feedback for Myoelectric Hand Prosthesis |
title | Optimization of Semiautomated Calibration Algorithm of Multichannel Electrotactile Feedback for Myoelectric Hand Prosthesis |
title_full | Optimization of Semiautomated Calibration Algorithm of Multichannel Electrotactile Feedback for Myoelectric Hand Prosthesis |
title_fullStr | Optimization of Semiautomated Calibration Algorithm of Multichannel Electrotactile Feedback for Myoelectric Hand Prosthesis |
title_full_unstemmed | Optimization of Semiautomated Calibration Algorithm of Multichannel Electrotactile Feedback for Myoelectric Hand Prosthesis |
title_short | Optimization of Semiautomated Calibration Algorithm of Multichannel Electrotactile Feedback for Myoelectric Hand Prosthesis |
title_sort | optimization of semiautomated calibration algorithm of multichannel electrotactile feedback for myoelectric hand prosthesis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6437744/ https://www.ncbi.nlm.nih.gov/pubmed/31001360 http://dx.doi.org/10.1155/2019/9298758 |
work_keys_str_mv | AT isakovicmilica optimizationofsemiautomatedcalibrationalgorithmofmultichannelelectrotactilefeedbackformyoelectrichandprosthesis AT malesevicjovana optimizationofsemiautomatedcalibrationalgorithmofmultichannelelectrotactilefeedbackformyoelectrichandprosthesis AT kellerthierry optimizationofsemiautomatedcalibrationalgorithmofmultichannelelectrotactilefeedbackformyoelectrichandprosthesis AT kosticmilos optimizationofsemiautomatedcalibrationalgorithmofmultichannelelectrotactilefeedbackformyoelectrichandprosthesis AT strbacmatija optimizationofsemiautomatedcalibrationalgorithmofmultichannelelectrotactilefeedbackformyoelectrichandprosthesis |