Cargando…

Evaluation of NanoDot Optically Stimulated Luminescence Dosimeter for Cone-shaped Small-field Dosimetry of Cyberknife Stereotactic Radiosurgery Unit: A Monte Carlo Simulation and Dosimetric Verification Study

AIM: The aim of this study was to investigate the adequacy of nanoDot optically stimulated luminescence (OSL) dosimeter for small field dosimetry before its in vivo applications in CyberKnife SRS unit. MATERIALS AND METHODS: A PTW 60018 SRS Diode, 60019 microDiamond, and Gafchromic EBT3 films were u...

Descripción completa

Detalles Bibliográficos
Autores principales: Akyol, Fadil, Sarigul, Neslihan, Yeginer, Mete, Yedekci, Yagiz, Utku, Haluk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6438048/
https://www.ncbi.nlm.nih.gov/pubmed/30983768
http://dx.doi.org/10.4103/jmp.JMP_96_18
_version_ 1783407049129852928
author Akyol, Fadil
Sarigul, Neslihan
Yeginer, Mete
Yedekci, Yagiz
Utku, Haluk
author_facet Akyol, Fadil
Sarigul, Neslihan
Yeginer, Mete
Yedekci, Yagiz
Utku, Haluk
author_sort Akyol, Fadil
collection PubMed
description AIM: The aim of this study was to investigate the adequacy of nanoDot optically stimulated luminescence (OSL) dosimeter for small field dosimetry before its in vivo applications in CyberKnife SRS unit. MATERIALS AND METHODS: A PTW 60018 SRS Diode, 60019 microDiamond, and Gafchromic EBT3 films were used along with a nanoDot carbon-doped aluminum oxide OSL dosimeter to collect and compare beam data. In addition, the EGSnrc/BEAMnrc code was employed to simulate 6-MV photon beams of CyberKnife SRS system. RESULTS: All detectors showed good consistency with each other in output factor measurements for cone sizes of 15 mm or more. The differences were maintained within 3% for these cones. However, OSL output factors showed higher discrepancies compared to those of other detectors for smaller cones wherein the difference reached nearly 40% for cone size of 5 mm. Depending on the performance of OSL dosimeter in terms of output factors, percentage depth doses (PDDs) were only measured for cones equal to or larger than 15 mm. The differences in PDD measurements were within 5% for depths in the range of 5–200 mm. CONCLUSION: Its low reliable readings for cones smaller than 15 mm should be considered before its in vivo applications of Cyberknife system.
format Online
Article
Text
id pubmed-6438048
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-64380482019-04-12 Evaluation of NanoDot Optically Stimulated Luminescence Dosimeter for Cone-shaped Small-field Dosimetry of Cyberknife Stereotactic Radiosurgery Unit: A Monte Carlo Simulation and Dosimetric Verification Study Akyol, Fadil Sarigul, Neslihan Yeginer, Mete Yedekci, Yagiz Utku, Haluk J Med Phys Original Article AIM: The aim of this study was to investigate the adequacy of nanoDot optically stimulated luminescence (OSL) dosimeter for small field dosimetry before its in vivo applications in CyberKnife SRS unit. MATERIALS AND METHODS: A PTW 60018 SRS Diode, 60019 microDiamond, and Gafchromic EBT3 films were used along with a nanoDot carbon-doped aluminum oxide OSL dosimeter to collect and compare beam data. In addition, the EGSnrc/BEAMnrc code was employed to simulate 6-MV photon beams of CyberKnife SRS system. RESULTS: All detectors showed good consistency with each other in output factor measurements for cone sizes of 15 mm or more. The differences were maintained within 3% for these cones. However, OSL output factors showed higher discrepancies compared to those of other detectors for smaller cones wherein the difference reached nearly 40% for cone size of 5 mm. Depending on the performance of OSL dosimeter in terms of output factors, percentage depth doses (PDDs) were only measured for cones equal to or larger than 15 mm. The differences in PDD measurements were within 5% for depths in the range of 5–200 mm. CONCLUSION: Its low reliable readings for cones smaller than 15 mm should be considered before its in vivo applications of Cyberknife system. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6438048/ /pubmed/30983768 http://dx.doi.org/10.4103/jmp.JMP_96_18 Text en Copyright: © 2019 Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Akyol, Fadil
Sarigul, Neslihan
Yeginer, Mete
Yedekci, Yagiz
Utku, Haluk
Evaluation of NanoDot Optically Stimulated Luminescence Dosimeter for Cone-shaped Small-field Dosimetry of Cyberknife Stereotactic Radiosurgery Unit: A Monte Carlo Simulation and Dosimetric Verification Study
title Evaluation of NanoDot Optically Stimulated Luminescence Dosimeter for Cone-shaped Small-field Dosimetry of Cyberknife Stereotactic Radiosurgery Unit: A Monte Carlo Simulation and Dosimetric Verification Study
title_full Evaluation of NanoDot Optically Stimulated Luminescence Dosimeter for Cone-shaped Small-field Dosimetry of Cyberknife Stereotactic Radiosurgery Unit: A Monte Carlo Simulation and Dosimetric Verification Study
title_fullStr Evaluation of NanoDot Optically Stimulated Luminescence Dosimeter for Cone-shaped Small-field Dosimetry of Cyberknife Stereotactic Radiosurgery Unit: A Monte Carlo Simulation and Dosimetric Verification Study
title_full_unstemmed Evaluation of NanoDot Optically Stimulated Luminescence Dosimeter for Cone-shaped Small-field Dosimetry of Cyberknife Stereotactic Radiosurgery Unit: A Monte Carlo Simulation and Dosimetric Verification Study
title_short Evaluation of NanoDot Optically Stimulated Luminescence Dosimeter for Cone-shaped Small-field Dosimetry of Cyberknife Stereotactic Radiosurgery Unit: A Monte Carlo Simulation and Dosimetric Verification Study
title_sort evaluation of nanodot optically stimulated luminescence dosimeter for cone-shaped small-field dosimetry of cyberknife stereotactic radiosurgery unit: a monte carlo simulation and dosimetric verification study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6438048/
https://www.ncbi.nlm.nih.gov/pubmed/30983768
http://dx.doi.org/10.4103/jmp.JMP_96_18
work_keys_str_mv AT akyolfadil evaluationofnanodotopticallystimulatedluminescencedosimeterforconeshapedsmallfielddosimetryofcyberknifestereotacticradiosurgeryunitamontecarlosimulationanddosimetricverificationstudy
AT sarigulneslihan evaluationofnanodotopticallystimulatedluminescencedosimeterforconeshapedsmallfielddosimetryofcyberknifestereotacticradiosurgeryunitamontecarlosimulationanddosimetricverificationstudy
AT yeginermete evaluationofnanodotopticallystimulatedluminescencedosimeterforconeshapedsmallfielddosimetryofcyberknifestereotacticradiosurgeryunitamontecarlosimulationanddosimetricverificationstudy
AT yedekciyagiz evaluationofnanodotopticallystimulatedluminescencedosimeterforconeshapedsmallfielddosimetryofcyberknifestereotacticradiosurgeryunitamontecarlosimulationanddosimetricverificationstudy
AT utkuhaluk evaluationofnanodotopticallystimulatedluminescencedosimeterforconeshapedsmallfielddosimetryofcyberknifestereotacticradiosurgeryunitamontecarlosimulationanddosimetricverificationstudy