Cargando…

Phantom-Based Feasibility Studies on Phase-Contrast Mammography at Indian Synchrotron Facility Indus-2

INTRODUCTION: Use of synchrotron radiation (SR) X-ray source in medical imaging has shown great potential for improving soft-tissue image contrast such as the breast. The present study demonstrates quantitative X-ray phase-contrast imaging (XPCI) technique derived from propagation-dependent phase ch...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharma, Reena, Sharma, S. D., Sarkar, P. S., Singh, B., Agrawal, A. K., Datta, D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6438051/
https://www.ncbi.nlm.nih.gov/pubmed/30983770
http://dx.doi.org/10.4103/jmp.JMP_98_18
_version_ 1783407049814573056
author Sharma, Reena
Sharma, S. D.
Sarkar, P. S.
Singh, B.
Agrawal, A. K.
Datta, D.
author_facet Sharma, Reena
Sharma, S. D.
Sarkar, P. S.
Singh, B.
Agrawal, A. K.
Datta, D.
author_sort Sharma, Reena
collection PubMed
description INTRODUCTION: Use of synchrotron radiation (SR) X-ray source in medical imaging has shown great potential for improving soft-tissue image contrast such as the breast. The present study demonstrates quantitative X-ray phase-contrast imaging (XPCI) technique derived from propagation-dependent phase change observed in the breast tissue-equivalent test materials. MATERIALS AND METHODS: Indian synchrotron facility (Indus-2, Raja Ramanna Centre of Advanced Technology [RRCAT]) was used to carry out phantom feasibility study on phase-contrast mammography. Different phantoms and samples, including locally fabricated breast tissue-equivalent phantoms were used to perform absorption and phase mode imaging using 12 and 16 keV SR X-ray beam. Edge-enhancement index (EEI) and edge enhancement to noise ratio (EE/N) were measured for all the images. Absorbed dose to air values were calculated for 12 and 16 keV SR X-ray beam using the measured SR X-ray photon flux at the object plane and by applying the standard radiation dosimetry formalism. RESULTS AND CONCLUSION: It was observed in case of all the phantoms and test samples that EEI and EE/N values are relatively higher for images taken in the phase mode. The absorbed dose to air at imaging plane was found to be 75.59 mGy and 28.9 mGy for 12 and 16 keV SR energies, respectively. However, these dose values can be optimized by reducing the image acquisition time without compromising the image quality when clinical samples are imaged. This work demonstrates the feasibility of XPCI in mammography using 12 and 16 keV SR X-ray beams.
format Online
Article
Text
id pubmed-6438051
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-64380512019-04-12 Phantom-Based Feasibility Studies on Phase-Contrast Mammography at Indian Synchrotron Facility Indus-2 Sharma, Reena Sharma, S. D. Sarkar, P. S. Singh, B. Agrawal, A. K. Datta, D. J Med Phys Original Article INTRODUCTION: Use of synchrotron radiation (SR) X-ray source in medical imaging has shown great potential for improving soft-tissue image contrast such as the breast. The present study demonstrates quantitative X-ray phase-contrast imaging (XPCI) technique derived from propagation-dependent phase change observed in the breast tissue-equivalent test materials. MATERIALS AND METHODS: Indian synchrotron facility (Indus-2, Raja Ramanna Centre of Advanced Technology [RRCAT]) was used to carry out phantom feasibility study on phase-contrast mammography. Different phantoms and samples, including locally fabricated breast tissue-equivalent phantoms were used to perform absorption and phase mode imaging using 12 and 16 keV SR X-ray beam. Edge-enhancement index (EEI) and edge enhancement to noise ratio (EE/N) were measured for all the images. Absorbed dose to air values were calculated for 12 and 16 keV SR X-ray beam using the measured SR X-ray photon flux at the object plane and by applying the standard radiation dosimetry formalism. RESULTS AND CONCLUSION: It was observed in case of all the phantoms and test samples that EEI and EE/N values are relatively higher for images taken in the phase mode. The absorbed dose to air at imaging plane was found to be 75.59 mGy and 28.9 mGy for 12 and 16 keV SR energies, respectively. However, these dose values can be optimized by reducing the image acquisition time without compromising the image quality when clinical samples are imaged. This work demonstrates the feasibility of XPCI in mammography using 12 and 16 keV SR X-ray beams. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6438051/ /pubmed/30983770 http://dx.doi.org/10.4103/jmp.JMP_98_18 Text en Copyright: © 2019 Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Sharma, Reena
Sharma, S. D.
Sarkar, P. S.
Singh, B.
Agrawal, A. K.
Datta, D.
Phantom-Based Feasibility Studies on Phase-Contrast Mammography at Indian Synchrotron Facility Indus-2
title Phantom-Based Feasibility Studies on Phase-Contrast Mammography at Indian Synchrotron Facility Indus-2
title_full Phantom-Based Feasibility Studies on Phase-Contrast Mammography at Indian Synchrotron Facility Indus-2
title_fullStr Phantom-Based Feasibility Studies on Phase-Contrast Mammography at Indian Synchrotron Facility Indus-2
title_full_unstemmed Phantom-Based Feasibility Studies on Phase-Contrast Mammography at Indian Synchrotron Facility Indus-2
title_short Phantom-Based Feasibility Studies on Phase-Contrast Mammography at Indian Synchrotron Facility Indus-2
title_sort phantom-based feasibility studies on phase-contrast mammography at indian synchrotron facility indus-2
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6438051/
https://www.ncbi.nlm.nih.gov/pubmed/30983770
http://dx.doi.org/10.4103/jmp.JMP_98_18
work_keys_str_mv AT sharmareena phantombasedfeasibilitystudiesonphasecontrastmammographyatindiansynchrotronfacilityindus2
AT sharmasd phantombasedfeasibilitystudiesonphasecontrastmammographyatindiansynchrotronfacilityindus2
AT sarkarps phantombasedfeasibilitystudiesonphasecontrastmammographyatindiansynchrotronfacilityindus2
AT singhb phantombasedfeasibilitystudiesonphasecontrastmammographyatindiansynchrotronfacilityindus2
AT agrawalak phantombasedfeasibilitystudiesonphasecontrastmammographyatindiansynchrotronfacilityindus2
AT dattad phantombasedfeasibilitystudiesonphasecontrastmammographyatindiansynchrotronfacilityindus2