Cargando…

Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping

INTRODUCTION: Robotic-assisted total mesorectal excision (TME) with pelvic intraoperative neuromapping was recently accomplished. However, neuromapping is conventionally conducted by a hand-guided laparoscopic probe. We introduce a prototype microfork probe to make robotic-guided neuromapping feasib...

Descripción completa

Detalles Bibliográficos
Autores principales: Schiemer, Jonas F., Juo, Yen-Yi Y., Sanaiha, Yas, Lin, Anne Y., Kazanjian, Kevork, Lang, Hauke, Kneist, Werner
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6438075/
https://www.ncbi.nlm.nih.gov/pubmed/29582794
http://dx.doi.org/10.4103/jmas.JMAS_12_18
_version_ 1783407055368880128
author Schiemer, Jonas F.
Juo, Yen-Yi Y.
Sanaiha, Yas
Lin, Anne Y.
Kazanjian, Kevork
Lang, Hauke
Kneist, Werner
author_facet Schiemer, Jonas F.
Juo, Yen-Yi Y.
Sanaiha, Yas
Lin, Anne Y.
Kazanjian, Kevork
Lang, Hauke
Kneist, Werner
author_sort Schiemer, Jonas F.
collection PubMed
description INTRODUCTION: Robotic-assisted total mesorectal excision (TME) with pelvic intraoperative neuromapping was recently accomplished. However, neuromapping is conventionally conducted by a hand-guided laparoscopic probe. We introduce a prototype microfork probe to make robotic-guided neuromapping feasible. EXPERIMENTS AND TECHNICAL SETUP: Two porcine experiments with nerve-sparing TME surgery were performed. A newly designed prototype bipolar microfork probe was inserted intraabdominally and guided with the robotic forceps. Intermittent neuromapping was then conducted and neuromonitoring data integrated in the surgeon console viewer. CONCLUSION: Robotic-guided neuromapping is shown to be feasible and fully controllable from the surgeon console.
format Online
Article
Text
id pubmed-6438075
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-64380752019-04-13 Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping Schiemer, Jonas F. Juo, Yen-Yi Y. Sanaiha, Yas Lin, Anne Y. Kazanjian, Kevork Lang, Hauke Kneist, Werner J Minim Access Surg Instruments and Equipments INTRODUCTION: Robotic-assisted total mesorectal excision (TME) with pelvic intraoperative neuromapping was recently accomplished. However, neuromapping is conventionally conducted by a hand-guided laparoscopic probe. We introduce a prototype microfork probe to make robotic-guided neuromapping feasible. EXPERIMENTS AND TECHNICAL SETUP: Two porcine experiments with nerve-sparing TME surgery were performed. A newly designed prototype bipolar microfork probe was inserted intraabdominally and guided with the robotic forceps. Intermittent neuromapping was then conducted and neuromonitoring data integrated in the surgeon console viewer. CONCLUSION: Robotic-guided neuromapping is shown to be feasible and fully controllable from the surgeon console. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6438075/ /pubmed/29582794 http://dx.doi.org/10.4103/jmas.JMAS_12_18 Text en Copyright: © 2018 Journal of Minimal Access Surgery http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Instruments and Equipments
Schiemer, Jonas F.
Juo, Yen-Yi Y.
Sanaiha, Yas
Lin, Anne Y.
Kazanjian, Kevork
Lang, Hauke
Kneist, Werner
Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping
title Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping
title_full Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping
title_fullStr Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping
title_full_unstemmed Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping
title_short Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping
title_sort application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping
topic Instruments and Equipments
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6438075/
https://www.ncbi.nlm.nih.gov/pubmed/29582794
http://dx.doi.org/10.4103/jmas.JMAS_12_18
work_keys_str_mv AT schiemerjonasf applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping
AT juoyenyiy applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping
AT sanaihayas applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping
AT linanney applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping
AT kazanjiankevork applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping
AT langhauke applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping
AT kneistwerner applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping