Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping
INTRODUCTION: Robotic-assisted total mesorectal excision (TME) with pelvic intraoperative neuromapping was recently accomplished. However, neuromapping is conventionally conducted by a hand-guided laparoscopic probe. We introduce a prototype microfork probe to make robotic-guided neuromapping feasib...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6438075/ https://www.ncbi.nlm.nih.gov/pubmed/29582794 http://dx.doi.org/10.4103/jmas.JMAS_12_18 |
_version_ | 1783407055368880128 |
---|---|
author | Schiemer, Jonas F. Juo, Yen-Yi Y. Sanaiha, Yas Lin, Anne Y. Kazanjian, Kevork Lang, Hauke Kneist, Werner |
author_facet | Schiemer, Jonas F. Juo, Yen-Yi Y. Sanaiha, Yas Lin, Anne Y. Kazanjian, Kevork Lang, Hauke Kneist, Werner |
author_sort | Schiemer, Jonas F. |
collection | PubMed |
description | INTRODUCTION: Robotic-assisted total mesorectal excision (TME) with pelvic intraoperative neuromapping was recently accomplished. However, neuromapping is conventionally conducted by a hand-guided laparoscopic probe. We introduce a prototype microfork probe to make robotic-guided neuromapping feasible. EXPERIMENTS AND TECHNICAL SETUP: Two porcine experiments with nerve-sparing TME surgery were performed. A newly designed prototype bipolar microfork probe was inserted intraabdominally and guided with the robotic forceps. Intermittent neuromapping was then conducted and neuromonitoring data integrated in the surgeon console viewer. CONCLUSION: Robotic-guided neuromapping is shown to be feasible and fully controllable from the surgeon console. |
format | Online Article Text |
id | pubmed-6438075 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-64380752019-04-13 Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping Schiemer, Jonas F. Juo, Yen-Yi Y. Sanaiha, Yas Lin, Anne Y. Kazanjian, Kevork Lang, Hauke Kneist, Werner J Minim Access Surg Instruments and Equipments INTRODUCTION: Robotic-assisted total mesorectal excision (TME) with pelvic intraoperative neuromapping was recently accomplished. However, neuromapping is conventionally conducted by a hand-guided laparoscopic probe. We introduce a prototype microfork probe to make robotic-guided neuromapping feasible. EXPERIMENTS AND TECHNICAL SETUP: Two porcine experiments with nerve-sparing TME surgery were performed. A newly designed prototype bipolar microfork probe was inserted intraabdominally and guided with the robotic forceps. Intermittent neuromapping was then conducted and neuromonitoring data integrated in the surgeon console viewer. CONCLUSION: Robotic-guided neuromapping is shown to be feasible and fully controllable from the surgeon console. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6438075/ /pubmed/29582794 http://dx.doi.org/10.4103/jmas.JMAS_12_18 Text en Copyright: © 2018 Journal of Minimal Access Surgery http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Instruments and Equipments Schiemer, Jonas F. Juo, Yen-Yi Y. Sanaiha, Yas Lin, Anne Y. Kazanjian, Kevork Lang, Hauke Kneist, Werner Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping |
title | Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping |
title_full | Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping |
title_fullStr | Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping |
title_full_unstemmed | Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping |
title_short | Application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping |
title_sort | application of a newly designed microfork probe for robotic-guided pelvic intraoperative neuromapping |
topic | Instruments and Equipments |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6438075/ https://www.ncbi.nlm.nih.gov/pubmed/29582794 http://dx.doi.org/10.4103/jmas.JMAS_12_18 |
work_keys_str_mv | AT schiemerjonasf applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping AT juoyenyiy applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping AT sanaihayas applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping AT linanney applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping AT kazanjiankevork applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping AT langhauke applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping AT kneistwerner applicationofanewlydesignedmicroforkprobeforroboticguidedpelvicintraoperativeneuromapping |