Cargando…

Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems

Microstructure imaging techniques based on tensor-valued diffusion encoding have gained popularity within the MRI research community. Unlike conventional diffusion encoding—applied along a single direction in each shot—tensor-valued encoding employs diffusion encoding along multiple directions withi...

Descripción completa

Detalles Bibliográficos
Autores principales: Szczepankiewicz, Filip, Sjölund, Jens, Ståhlberg, Freddy, Lätt, Jimmy, Nilsson, Markus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6438503/
https://www.ncbi.nlm.nih.gov/pubmed/30921381
http://dx.doi.org/10.1371/journal.pone.0214238
_version_ 1783407110379274240
author Szczepankiewicz, Filip
Sjölund, Jens
Ståhlberg, Freddy
Lätt, Jimmy
Nilsson, Markus
author_facet Szczepankiewicz, Filip
Sjölund, Jens
Ståhlberg, Freddy
Lätt, Jimmy
Nilsson, Markus
author_sort Szczepankiewicz, Filip
collection PubMed
description Microstructure imaging techniques based on tensor-valued diffusion encoding have gained popularity within the MRI research community. Unlike conventional diffusion encoding—applied along a single direction in each shot—tensor-valued encoding employs diffusion encoding along multiple directions within a single preparation of the signal. The benefit is that such encoding may probe tissue features that are not accessible by conventional encoding. For example, diffusional variance decomposition (DIVIDE) takes advantage of tensor-valued encoding to probe microscopic diffusion anisotropy independent of orientation coherence. The drawback is that tensor-valued encoding generally requires gradient waveforms that are more demanding on hardware; it has therefore been used primarily in MRI systems with relatively high performance. The purpose of this work was to explore tensor-valued diffusion encoding on clinical MRI systems with varying performance to test its technical feasibility within the context of DIVIDE. We performed whole-brain imaging with linear and spherical b-tensor encoding at field strengths between 1.5 and 7 T, and at maximal gradient amplitudes between 45 and 80 mT/m. Asymmetric gradient waveforms were optimized numerically to yield b-values up to 2 ms/μm(2). Technical feasibility was assessed in terms of the repeatability, SNR, and quality of DIVIDE parameter maps. Variable system performance resulted in echo times between 83 to 115 ms and total acquisition times of 6 to 9 minutes when using 80 signal samples and resolution 2×2×4 mm(3). As expected, the repeatability, signal-to-noise ratio and parameter map quality depended on hardware performance. We conclude that tensor-valued encoding is feasible for a wide range of MRI systems—even at 1.5 T with maximal gradient waveform amplitudes of 33 mT/m—and baseline experimental design and quality parameters for all included configurations. This demonstrates that tissue features, beyond those accessible by conventional diffusion encoding, can be explored on a wide range of MRI systems.
format Online
Article
Text
id pubmed-6438503
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-64385032019-04-12 Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems Szczepankiewicz, Filip Sjölund, Jens Ståhlberg, Freddy Lätt, Jimmy Nilsson, Markus PLoS One Research Article Microstructure imaging techniques based on tensor-valued diffusion encoding have gained popularity within the MRI research community. Unlike conventional diffusion encoding—applied along a single direction in each shot—tensor-valued encoding employs diffusion encoding along multiple directions within a single preparation of the signal. The benefit is that such encoding may probe tissue features that are not accessible by conventional encoding. For example, diffusional variance decomposition (DIVIDE) takes advantage of tensor-valued encoding to probe microscopic diffusion anisotropy independent of orientation coherence. The drawback is that tensor-valued encoding generally requires gradient waveforms that are more demanding on hardware; it has therefore been used primarily in MRI systems with relatively high performance. The purpose of this work was to explore tensor-valued diffusion encoding on clinical MRI systems with varying performance to test its technical feasibility within the context of DIVIDE. We performed whole-brain imaging with linear and spherical b-tensor encoding at field strengths between 1.5 and 7 T, and at maximal gradient amplitudes between 45 and 80 mT/m. Asymmetric gradient waveforms were optimized numerically to yield b-values up to 2 ms/μm(2). Technical feasibility was assessed in terms of the repeatability, SNR, and quality of DIVIDE parameter maps. Variable system performance resulted in echo times between 83 to 115 ms and total acquisition times of 6 to 9 minutes when using 80 signal samples and resolution 2×2×4 mm(3). As expected, the repeatability, signal-to-noise ratio and parameter map quality depended on hardware performance. We conclude that tensor-valued encoding is feasible for a wide range of MRI systems—even at 1.5 T with maximal gradient waveform amplitudes of 33 mT/m—and baseline experimental design and quality parameters for all included configurations. This demonstrates that tissue features, beyond those accessible by conventional diffusion encoding, can be explored on a wide range of MRI systems. Public Library of Science 2019-03-28 /pmc/articles/PMC6438503/ /pubmed/30921381 http://dx.doi.org/10.1371/journal.pone.0214238 Text en © 2019 Szczepankiewicz et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Szczepankiewicz, Filip
Sjölund, Jens
Ståhlberg, Freddy
Lätt, Jimmy
Nilsson, Markus
Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems
title Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems
title_full Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems
title_fullStr Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems
title_full_unstemmed Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems
title_short Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems
title_sort tensor-valued diffusion encoding for diffusional variance decomposition (divide): technical feasibility in clinical mri systems
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6438503/
https://www.ncbi.nlm.nih.gov/pubmed/30921381
http://dx.doi.org/10.1371/journal.pone.0214238
work_keys_str_mv AT szczepankiewiczfilip tensorvalueddiffusionencodingfordiffusionalvariancedecompositiondividetechnicalfeasibilityinclinicalmrisystems
AT sjolundjens tensorvalueddiffusionencodingfordiffusionalvariancedecompositiondividetechnicalfeasibilityinclinicalmrisystems
AT stahlbergfreddy tensorvalueddiffusionencodingfordiffusionalvariancedecompositiondividetechnicalfeasibilityinclinicalmrisystems
AT lattjimmy tensorvalueddiffusionencodingfordiffusionalvariancedecompositiondividetechnicalfeasibilityinclinicalmrisystems
AT nilssonmarkus tensorvalueddiffusionencodingfordiffusionalvariancedecompositiondividetechnicalfeasibilityinclinicalmrisystems