Cargando…

Impaired endogenous fibrinolysis at high shear using a point-of-care test in STEMI is associated with alterations in clot architecture

Impaired endogenous fibrinolysis is an adverse prognostic biomarker in acute coronary syndrome (ACS). Abnormally dense in vitro fibrin thrombi have been demonstrated in ACS patients and related to hypofibrinolysis using cumbersome, laboratory-based methods. We aimed to assess endogenous fibrinolysis...

Descripción completa

Detalles Bibliográficos
Autores principales: Spinthakis, Nikolaos, Gue, Ying, Farag, Mohamed, Ren, Guogang, Srinivasan, Manivannan, Baydoun, Anwar, Gorog, Diana A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6439169/
https://www.ncbi.nlm.nih.gov/pubmed/30739303
http://dx.doi.org/10.1007/s11239-018-01799-1
_version_ 1783407206802128896
author Spinthakis, Nikolaos
Gue, Ying
Farag, Mohamed
Ren, Guogang
Srinivasan, Manivannan
Baydoun, Anwar
Gorog, Diana A.
author_facet Spinthakis, Nikolaos
Gue, Ying
Farag, Mohamed
Ren, Guogang
Srinivasan, Manivannan
Baydoun, Anwar
Gorog, Diana A.
author_sort Spinthakis, Nikolaos
collection PubMed
description Impaired endogenous fibrinolysis is an adverse prognostic biomarker in acute coronary syndrome (ACS). Abnormally dense in vitro fibrin thrombi have been demonstrated in ACS patients and related to hypofibrinolysis using cumbersome, laboratory-based methods. We aimed to assess endogenous fibrinolysis using a point-of-care technique and relate this to clot architecture. From patients with ST-segment elevation myocardial infarction (STEMI), venous blood was drawn immediately on arrival to assess thrombotic status. Blood was assessed using the point-of-care Global Thrombosis Test which measures occlusive thrombus formation under high shear and subsequently endogenous fibrinolysis (lysis time, LT). Two samples per patient were run in parallel. In one channel, the measurement was allowed to proceed as normal. In the other, after occlusion, thrombus was extracted, washed, fixed in glutaraldehyde, dried, sputter-coated, and assessed using scanning electron microscope. Endogenous fibrinolysis was strongly associated fibrin fibre thickness (p = 0.0001). As LT increased (less efficient fibrinolysis), the fibrin network of the thrombus was significantly more compact and dense, with thinner fibrin fibres and smaller gaps. Fibrin fibre thickness correlated inversely with LT (r = − 0.89, p = 0.001). Adverse clot architecture in vitro is directly related to impaired endogenous fibrinolysis using a relatively new point-of-care technique in patients with STEMI. This may transform the relevance of fibrin clot architecture from an off-line laboratory association to being directly relevant to endogenous fibrinolysis at the patient bedside, which could be used as a near-patient test to guide prognosis and assess the effect of treatment.
format Online
Article
Text
id pubmed-6439169
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-64391692019-04-15 Impaired endogenous fibrinolysis at high shear using a point-of-care test in STEMI is associated with alterations in clot architecture Spinthakis, Nikolaos Gue, Ying Farag, Mohamed Ren, Guogang Srinivasan, Manivannan Baydoun, Anwar Gorog, Diana A. J Thromb Thrombolysis Article Impaired endogenous fibrinolysis is an adverse prognostic biomarker in acute coronary syndrome (ACS). Abnormally dense in vitro fibrin thrombi have been demonstrated in ACS patients and related to hypofibrinolysis using cumbersome, laboratory-based methods. We aimed to assess endogenous fibrinolysis using a point-of-care technique and relate this to clot architecture. From patients with ST-segment elevation myocardial infarction (STEMI), venous blood was drawn immediately on arrival to assess thrombotic status. Blood was assessed using the point-of-care Global Thrombosis Test which measures occlusive thrombus formation under high shear and subsequently endogenous fibrinolysis (lysis time, LT). Two samples per patient were run in parallel. In one channel, the measurement was allowed to proceed as normal. In the other, after occlusion, thrombus was extracted, washed, fixed in glutaraldehyde, dried, sputter-coated, and assessed using scanning electron microscope. Endogenous fibrinolysis was strongly associated fibrin fibre thickness (p = 0.0001). As LT increased (less efficient fibrinolysis), the fibrin network of the thrombus was significantly more compact and dense, with thinner fibrin fibres and smaller gaps. Fibrin fibre thickness correlated inversely with LT (r = − 0.89, p = 0.001). Adverse clot architecture in vitro is directly related to impaired endogenous fibrinolysis using a relatively new point-of-care technique in patients with STEMI. This may transform the relevance of fibrin clot architecture from an off-line laboratory association to being directly relevant to endogenous fibrinolysis at the patient bedside, which could be used as a near-patient test to guide prognosis and assess the effect of treatment. Springer US 2019-02-09 2019 /pmc/articles/PMC6439169/ /pubmed/30739303 http://dx.doi.org/10.1007/s11239-018-01799-1 Text en © The Author(s) 2019 OpenAccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Article
Spinthakis, Nikolaos
Gue, Ying
Farag, Mohamed
Ren, Guogang
Srinivasan, Manivannan
Baydoun, Anwar
Gorog, Diana A.
Impaired endogenous fibrinolysis at high shear using a point-of-care test in STEMI is associated with alterations in clot architecture
title Impaired endogenous fibrinolysis at high shear using a point-of-care test in STEMI is associated with alterations in clot architecture
title_full Impaired endogenous fibrinolysis at high shear using a point-of-care test in STEMI is associated with alterations in clot architecture
title_fullStr Impaired endogenous fibrinolysis at high shear using a point-of-care test in STEMI is associated with alterations in clot architecture
title_full_unstemmed Impaired endogenous fibrinolysis at high shear using a point-of-care test in STEMI is associated with alterations in clot architecture
title_short Impaired endogenous fibrinolysis at high shear using a point-of-care test in STEMI is associated with alterations in clot architecture
title_sort impaired endogenous fibrinolysis at high shear using a point-of-care test in stemi is associated with alterations in clot architecture
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6439169/
https://www.ncbi.nlm.nih.gov/pubmed/30739303
http://dx.doi.org/10.1007/s11239-018-01799-1
work_keys_str_mv AT spinthakisnikolaos impairedendogenousfibrinolysisathighshearusingapointofcaretestinstemiisassociatedwithalterationsinclotarchitecture
AT gueying impairedendogenousfibrinolysisathighshearusingapointofcaretestinstemiisassociatedwithalterationsinclotarchitecture
AT faragmohamed impairedendogenousfibrinolysisathighshearusingapointofcaretestinstemiisassociatedwithalterationsinclotarchitecture
AT renguogang impairedendogenousfibrinolysisathighshearusingapointofcaretestinstemiisassociatedwithalterationsinclotarchitecture
AT srinivasanmanivannan impairedendogenousfibrinolysisathighshearusingapointofcaretestinstemiisassociatedwithalterationsinclotarchitecture
AT baydounanwar impairedendogenousfibrinolysisathighshearusingapointofcaretestinstemiisassociatedwithalterationsinclotarchitecture
AT gorogdianaa impairedendogenousfibrinolysisathighshearusingapointofcaretestinstemiisassociatedwithalterationsinclotarchitecture