Cargando…

The added value of three-dimensional echocardiography in the late diagnosis of a pacemaker complication in a patient with severe congestive heart failure: a case report

BACKGROUND: Three-dimensional echocardiography (3DE) presents an increasingly important role in the management of interventional cardiac procedures, overcoming limitations of conventional two-dimensional echocardiography (2DE). Early use of 3DE might have an added value in the diagnosis of device-re...

Descripción completa

Detalles Bibliográficos
Autores principales: Mihaila Baldea, Sorina, Velcea, Andreea Elena, Siliste, Calin, Vinereanu, Dragos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6439365/
https://www.ncbi.nlm.nih.gov/pubmed/31020249
http://dx.doi.org/10.1093/ehjcr/ytz004
_version_ 1783407248599416832
author Mihaila Baldea, Sorina
Velcea, Andreea Elena
Siliste, Calin
Vinereanu, Dragos
author_facet Mihaila Baldea, Sorina
Velcea, Andreea Elena
Siliste, Calin
Vinereanu, Dragos
author_sort Mihaila Baldea, Sorina
collection PubMed
description BACKGROUND: Three-dimensional echocardiography (3DE) presents an increasingly important role in the management of interventional cardiac procedures, overcoming limitations of conventional two-dimensional echocardiography (2DE). Early use of 3DE might have an added value in the diagnosis of device-related complications, such as lead induced tricuspid regurgitation (LITR), by providing better understanding of its mechanisms and ensuring a prompt and individually tailored treatment strategy. CASE SUMMARY: We report the case of a female patient with repeated hospitalizations for congestive heart failure in the past 2 years, who had a permanent single-chamber ventricular pacemaker (PM) implanted 10 years ago and a misleading diagnosis of severe tricuspid regurgitation (TR) secondary to annular dilation, based on 2DE. Conversely, current 3DE assessment of the TR mechanisms revealed that the PM lead was not placed between the commissures, but in the middle segment of the septal leaflet, causing impingement of the leaflet and severe TR. DISCUSSION: Given the growing indication for cardiac devices, it is necessary to better define LITR and to establish its impact on patient prognosis. Due to lacking in proper diagnostic techniques, LITR is generally recognized as a late complication of PM/ICD implantation. Two-dimensional echocardiography has important limitations, whereas 3DE provides more accurate information on the TV apparatus in relation to the endocardial leads. Our case shows the usefulness of 3DE for a correct diagnosis of a device-related complication. Its utility in the follow-up of patients receiving cardiac devices remains to be determined, as well as its potential value in the guidance of lead insertion.
format Online
Article
Text
id pubmed-6439365
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-64393652019-04-24 The added value of three-dimensional echocardiography in the late diagnosis of a pacemaker complication in a patient with severe congestive heart failure: a case report Mihaila Baldea, Sorina Velcea, Andreea Elena Siliste, Calin Vinereanu, Dragos Eur Heart J Case Rep Case Reports BACKGROUND: Three-dimensional echocardiography (3DE) presents an increasingly important role in the management of interventional cardiac procedures, overcoming limitations of conventional two-dimensional echocardiography (2DE). Early use of 3DE might have an added value in the diagnosis of device-related complications, such as lead induced tricuspid regurgitation (LITR), by providing better understanding of its mechanisms and ensuring a prompt and individually tailored treatment strategy. CASE SUMMARY: We report the case of a female patient with repeated hospitalizations for congestive heart failure in the past 2 years, who had a permanent single-chamber ventricular pacemaker (PM) implanted 10 years ago and a misleading diagnosis of severe tricuspid regurgitation (TR) secondary to annular dilation, based on 2DE. Conversely, current 3DE assessment of the TR mechanisms revealed that the PM lead was not placed between the commissures, but in the middle segment of the septal leaflet, causing impingement of the leaflet and severe TR. DISCUSSION: Given the growing indication for cardiac devices, it is necessary to better define LITR and to establish its impact on patient prognosis. Due to lacking in proper diagnostic techniques, LITR is generally recognized as a late complication of PM/ICD implantation. Two-dimensional echocardiography has important limitations, whereas 3DE provides more accurate information on the TV apparatus in relation to the endocardial leads. Our case shows the usefulness of 3DE for a correct diagnosis of a device-related complication. Its utility in the follow-up of patients receiving cardiac devices remains to be determined, as well as its potential value in the guidance of lead insertion. Oxford University Press 2019-02-21 /pmc/articles/PMC6439365/ /pubmed/31020249 http://dx.doi.org/10.1093/ehjcr/ytz004 Text en © The Author(s) 2019. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Reports
Mihaila Baldea, Sorina
Velcea, Andreea Elena
Siliste, Calin
Vinereanu, Dragos
The added value of three-dimensional echocardiography in the late diagnosis of a pacemaker complication in a patient with severe congestive heart failure: a case report
title The added value of three-dimensional echocardiography in the late diagnosis of a pacemaker complication in a patient with severe congestive heart failure: a case report
title_full The added value of three-dimensional echocardiography in the late diagnosis of a pacemaker complication in a patient with severe congestive heart failure: a case report
title_fullStr The added value of three-dimensional echocardiography in the late diagnosis of a pacemaker complication in a patient with severe congestive heart failure: a case report
title_full_unstemmed The added value of three-dimensional echocardiography in the late diagnosis of a pacemaker complication in a patient with severe congestive heart failure: a case report
title_short The added value of three-dimensional echocardiography in the late diagnosis of a pacemaker complication in a patient with severe congestive heart failure: a case report
title_sort added value of three-dimensional echocardiography in the late diagnosis of a pacemaker complication in a patient with severe congestive heart failure: a case report
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6439365/
https://www.ncbi.nlm.nih.gov/pubmed/31020249
http://dx.doi.org/10.1093/ehjcr/ytz004
work_keys_str_mv AT mihailabaldeasorina theaddedvalueofthreedimensionalechocardiographyinthelatediagnosisofapacemakercomplicationinapatientwithseverecongestiveheartfailureacasereport
AT velceaandreeaelena theaddedvalueofthreedimensionalechocardiographyinthelatediagnosisofapacemakercomplicationinapatientwithseverecongestiveheartfailureacasereport
AT silistecalin theaddedvalueofthreedimensionalechocardiographyinthelatediagnosisofapacemakercomplicationinapatientwithseverecongestiveheartfailureacasereport
AT vinereanudragos theaddedvalueofthreedimensionalechocardiographyinthelatediagnosisofapacemakercomplicationinapatientwithseverecongestiveheartfailureacasereport
AT mihailabaldeasorina addedvalueofthreedimensionalechocardiographyinthelatediagnosisofapacemakercomplicationinapatientwithseverecongestiveheartfailureacasereport
AT velceaandreeaelena addedvalueofthreedimensionalechocardiographyinthelatediagnosisofapacemakercomplicationinapatientwithseverecongestiveheartfailureacasereport
AT silistecalin addedvalueofthreedimensionalechocardiographyinthelatediagnosisofapacemakercomplicationinapatientwithseverecongestiveheartfailureacasereport
AT vinereanudragos addedvalueofthreedimensionalechocardiographyinthelatediagnosisofapacemakercomplicationinapatientwithseverecongestiveheartfailureacasereport