Cargando…

Measurement of Internal Jugular Vein and Common Carotid Artery Diameter Ratio by Ultrasound to Estimate Central Venous Pressure

Objective The objective of this study is to find a correlation between internal jugular vein (IJV) and common carotid artery (CCA) diameter ratio and central venous pressure (CVP) measurement and find a cut-off value for the IJV/CCA ratio to predict low CVP i.e. < 10 cm H(2)0, for estimating the...

Descripción completa

Detalles Bibliográficos
Autores principales: Bano, Sheher, Qadeer, Aayesha, Akhtar, Aftab, Ata ur-Rehman, Hafiz Muhammad, Munawar, Kamran, Hussain, Syed Waqar, Khan, Muhammad Tariq, Zafar, Rizwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6440552/
https://www.ncbi.nlm.nih.gov/pubmed/30949421
http://dx.doi.org/10.7759/cureus.2277
_version_ 1783407407372697600
author Bano, Sheher
Qadeer, Aayesha
Akhtar, Aftab
Ata ur-Rehman, Hafiz Muhammad
Munawar, Kamran
Hussain, Syed Waqar
Khan, Muhammad Tariq
Zafar, Rizwan
author_facet Bano, Sheher
Qadeer, Aayesha
Akhtar, Aftab
Ata ur-Rehman, Hafiz Muhammad
Munawar, Kamran
Hussain, Syed Waqar
Khan, Muhammad Tariq
Zafar, Rizwan
author_sort Bano, Sheher
collection PubMed
description Objective The objective of this study is to find a correlation between internal jugular vein (IJV) and common carotid artery (CCA) diameter ratio and central venous pressure (CVP) measurement and find a cut-off value for the IJV/CCA ratio to predict low CVP i.e. < 10 cm H(2)0, for estimating the volume status in critically ill patients. Methods This prospective cross-sectional study was conducted at the critical care department of Shifa International Hospital, Islamabad, from July to December 2017. A sample of 49 patients ≥ 18 years with intrathoracic central venous catheters (CVCs) who underwent bedside sonographic assessments of IJV and CCA diameter were included in this study using convenient sampling. The IJV/CCA diameter ratio was calculated and correlated with CVP and the predictive value of the IJV/CCA diameter ratio to predict CVP < 10 cm H(2)O was explored by calculating the area under the receiver operating characteristic (ROC) curve, sensitivity, specificity, and positive and negative predictive values. Results A total of 49 patients, 30 males (61.2%) and 19 females (38.8%) with a mean age of 56.00±16.11 years were included in the study. The mean CVP was 8.98±2.37cm H(2)O in ventilated (51%) and 10.7± 6.01 cm H(2)O in non-ventilated (49%) patients. The mean IJV/CCA diameter ratio was 1.60±0.55 at expiration and 1.41±0.56 at inspiration. There was a significant correlation between the IJV/CCA diameter ratio and CVP at expiration (r=0.401, p=0.004). The correlation between IJV/CCA and CVP was significant in non-ventilated patients at expiration (r=0.439, p=0.032). The area under the ROC curve for the IJV/CCA diameter ratio for predicting CVP < 10 cm H(2)O was 0.684 (p=0.028). The predictive value of the IJV/CCA diameter ratio for CVP < 10 cm H(2)0 at the cutoff value of < 2 was insignificant. A new cut-off < 1.75 was taken for the IJV/CCA diameter ratio from the coordinates of the ROC curve. The sensitivity, specificity, PPV, and NPV of an IJV/CCA diameter ratio of < 1.75 for predicting a CVP < 10 cm H(2)0 were 84.62%, 52.17%, 66.67%, and 75.00%, respectively. Conclusion The assessment of volume status by the IJV/CCA diameter ratio with a sonographic device may be a useful noninvasive alternative for a central venous catheterization with a cut-off < 1.75.
format Online
Article
Text
id pubmed-6440552
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-64405522019-04-04 Measurement of Internal Jugular Vein and Common Carotid Artery Diameter Ratio by Ultrasound to Estimate Central Venous Pressure Bano, Sheher Qadeer, Aayesha Akhtar, Aftab Ata ur-Rehman, Hafiz Muhammad Munawar, Kamran Hussain, Syed Waqar Khan, Muhammad Tariq Zafar, Rizwan Cureus Internal Medicine Objective The objective of this study is to find a correlation between internal jugular vein (IJV) and common carotid artery (CCA) diameter ratio and central venous pressure (CVP) measurement and find a cut-off value for the IJV/CCA ratio to predict low CVP i.e. < 10 cm H(2)0, for estimating the volume status in critically ill patients. Methods This prospective cross-sectional study was conducted at the critical care department of Shifa International Hospital, Islamabad, from July to December 2017. A sample of 49 patients ≥ 18 years with intrathoracic central venous catheters (CVCs) who underwent bedside sonographic assessments of IJV and CCA diameter were included in this study using convenient sampling. The IJV/CCA diameter ratio was calculated and correlated with CVP and the predictive value of the IJV/CCA diameter ratio to predict CVP < 10 cm H(2)O was explored by calculating the area under the receiver operating characteristic (ROC) curve, sensitivity, specificity, and positive and negative predictive values. Results A total of 49 patients, 30 males (61.2%) and 19 females (38.8%) with a mean age of 56.00±16.11 years were included in the study. The mean CVP was 8.98±2.37cm H(2)O in ventilated (51%) and 10.7± 6.01 cm H(2)O in non-ventilated (49%) patients. The mean IJV/CCA diameter ratio was 1.60±0.55 at expiration and 1.41±0.56 at inspiration. There was a significant correlation between the IJV/CCA diameter ratio and CVP at expiration (r=0.401, p=0.004). The correlation between IJV/CCA and CVP was significant in non-ventilated patients at expiration (r=0.439, p=0.032). The area under the ROC curve for the IJV/CCA diameter ratio for predicting CVP < 10 cm H(2)O was 0.684 (p=0.028). The predictive value of the IJV/CCA diameter ratio for CVP < 10 cm H(2)0 at the cutoff value of < 2 was insignificant. A new cut-off < 1.75 was taken for the IJV/CCA diameter ratio from the coordinates of the ROC curve. The sensitivity, specificity, PPV, and NPV of an IJV/CCA diameter ratio of < 1.75 for predicting a CVP < 10 cm H(2)0 were 84.62%, 52.17%, 66.67%, and 75.00%, respectively. Conclusion The assessment of volume status by the IJV/CCA diameter ratio with a sonographic device may be a useful noninvasive alternative for a central venous catheterization with a cut-off < 1.75. Cureus 2018-03-05 /pmc/articles/PMC6440552/ /pubmed/30949421 http://dx.doi.org/10.7759/cureus.2277 Text en Copyright © 2018, Bano et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Internal Medicine
Bano, Sheher
Qadeer, Aayesha
Akhtar, Aftab
Ata ur-Rehman, Hafiz Muhammad
Munawar, Kamran
Hussain, Syed Waqar
Khan, Muhammad Tariq
Zafar, Rizwan
Measurement of Internal Jugular Vein and Common Carotid Artery Diameter Ratio by Ultrasound to Estimate Central Venous Pressure
title Measurement of Internal Jugular Vein and Common Carotid Artery Diameter Ratio by Ultrasound to Estimate Central Venous Pressure
title_full Measurement of Internal Jugular Vein and Common Carotid Artery Diameter Ratio by Ultrasound to Estimate Central Venous Pressure
title_fullStr Measurement of Internal Jugular Vein and Common Carotid Artery Diameter Ratio by Ultrasound to Estimate Central Venous Pressure
title_full_unstemmed Measurement of Internal Jugular Vein and Common Carotid Artery Diameter Ratio by Ultrasound to Estimate Central Venous Pressure
title_short Measurement of Internal Jugular Vein and Common Carotid Artery Diameter Ratio by Ultrasound to Estimate Central Venous Pressure
title_sort measurement of internal jugular vein and common carotid artery diameter ratio by ultrasound to estimate central venous pressure
topic Internal Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6440552/
https://www.ncbi.nlm.nih.gov/pubmed/30949421
http://dx.doi.org/10.7759/cureus.2277
work_keys_str_mv AT banosheher measurementofinternaljugularveinandcommoncarotidarterydiameterratiobyultrasoundtoestimatecentralvenouspressure
AT qadeeraayesha measurementofinternaljugularveinandcommoncarotidarterydiameterratiobyultrasoundtoestimatecentralvenouspressure
AT akhtaraftab measurementofinternaljugularveinandcommoncarotidarterydiameterratiobyultrasoundtoestimatecentralvenouspressure
AT ataurrehmanhafizmuhammad measurementofinternaljugularveinandcommoncarotidarterydiameterratiobyultrasoundtoestimatecentralvenouspressure
AT munawarkamran measurementofinternaljugularveinandcommoncarotidarterydiameterratiobyultrasoundtoestimatecentralvenouspressure
AT hussainsyedwaqar measurementofinternaljugularveinandcommoncarotidarterydiameterratiobyultrasoundtoestimatecentralvenouspressure
AT khanmuhammadtariq measurementofinternaljugularveinandcommoncarotidarterydiameterratiobyultrasoundtoestimatecentralvenouspressure
AT zafarrizwan measurementofinternaljugularveinandcommoncarotidarterydiameterratiobyultrasoundtoestimatecentralvenouspressure