Performance of a Novel Low-Cost, Instrument-Free Plasma Separation Device for HIV Viral Load Quantification and Determination of Treatment Failure in People Living with HIV in Malaysia: a Diagnostic Accuracy Study

HIV viral load (VL) testing is the recommended method for monitoring the response of people living with HIV and receiving antiretroviral therapy (ART). The availability of standard plasma VL testing in low- and middle-income countries (LMICs), and access to this testing, are limited by the need to u...

Descripción completa

Detalles Bibliográficos
Autores principales: Pham, Minh D., Haile, Berhan A., Azwa, Iskandar, Kamarulzaman, Adeeba, Raman, Nishaan, Saeidi, Alireza, Kahar Bador, Maria, Tan, Margaret, Zhu, Jiawei, Feng, Yi, Elliott, Julian H., Garcia, Mary L., Li, Fan, Crowe, Suzanne M., Luchters, Stanley, Anderson, David A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6440787/
https://www.ncbi.nlm.nih.gov/pubmed/30700508
http://dx.doi.org/10.1128/JCM.01683-18
_version_ 1783407446310518784
author Pham, Minh D.
Haile, Berhan A.
Azwa, Iskandar
Kamarulzaman, Adeeba
Raman, Nishaan
Saeidi, Alireza
Kahar Bador, Maria
Tan, Margaret
Zhu, Jiawei
Feng, Yi
Elliott, Julian H.
Garcia, Mary L.
Li, Fan
Crowe, Suzanne M.
Luchters, Stanley
Anderson, David A.
author_facet Pham, Minh D.
Haile, Berhan A.
Azwa, Iskandar
Kamarulzaman, Adeeba
Raman, Nishaan
Saeidi, Alireza
Kahar Bador, Maria
Tan, Margaret
Zhu, Jiawei
Feng, Yi
Elliott, Julian H.
Garcia, Mary L.
Li, Fan
Crowe, Suzanne M.
Luchters, Stanley
Anderson, David A.
author_sort Pham, Minh D.
collection PubMed
description HIV viral load (VL) testing is the recommended method for monitoring the response of people living with HIV and receiving antiretroviral therapy (ART). The availability of standard plasma VL testing in low- and middle-income countries (LMICs), and access to this testing, are limited by the need to use fresh plasma. Good specimen collection methods for HIV VL testing that are applicable to resource-constrained settings are needed. We assessed the diagnostic performance of the filtered dried plasma spot (FDPS), created using the newly developed, instrument-free VLPlasma device, in identifying treatment failure at a VL threshold of 1,000 copies/ml in fresh plasma. Performance was compared with that of the conventional dried blood spot (DBS). Venous blood samples from 201 people living with HIV and attending an infectious disease clinic in Malaysia were collected, and HIV VL was quantified using fresh plasma (the reference standard), FDPS, and DBS specimens. VL testing was done using the Roche Cobas AmpliPrep/Cobas TaqMan v2.0 assay. At a threshold of 1,000 copies/ml, the diagnostic performance of the FDPS was superior (sensitivity, 100% [95% confidence interval {CI}, 89.1 to 100%]; specificity, 100% [95% CI, 97.8 to 100%]) to that of the DBS (sensitivity, 100% [95% CI, 89.4 to 100%]; specificity, 36.8% [95% CI, 29.4 to 44.7%]) (P < 0.001). A stronger correlation was observed between the FDPS VL and the plasma VL (r = 0.94; P < 0.001) than between the DBS VL and the plasma VL (r = 0.85; P < 0.001). The mean difference in VL measures between the FDPS and plasma (plasma VL minus FDPS VL) was 0.127 log(10) copies/ml (standard deviation [SD], 0.32), in contrast to –0.95 log(10) copies/ml (SD, 0.84) between the DBS and plasma. HIV VL measurement using the FDPS outperformed that with the DBS in identifying treatment failure at a threshold of 1,000 copies/ml and compared well with the quantification of VL in plasma. The FDPS can be an attractive alternative to fresh plasma for improving access to HIV VL monitoring among people living with HIV on ART in LMICs.
format Online
Article
Text
id pubmed-6440787
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-64407872019-07-05 Performance of a Novel Low-Cost, Instrument-Free Plasma Separation Device for HIV Viral Load Quantification and Determination of Treatment Failure in People Living with HIV in Malaysia: a Diagnostic Accuracy Study Pham, Minh D. Haile, Berhan A. Azwa, Iskandar Kamarulzaman, Adeeba Raman, Nishaan Saeidi, Alireza Kahar Bador, Maria Tan, Margaret Zhu, Jiawei Feng, Yi Elliott, Julian H. Garcia, Mary L. Li, Fan Crowe, Suzanne M. Luchters, Stanley Anderson, David A. J Clin Microbiol Immunoassays HIV viral load (VL) testing is the recommended method for monitoring the response of people living with HIV and receiving antiretroviral therapy (ART). The availability of standard plasma VL testing in low- and middle-income countries (LMICs), and access to this testing, are limited by the need to use fresh plasma. Good specimen collection methods for HIV VL testing that are applicable to resource-constrained settings are needed. We assessed the diagnostic performance of the filtered dried plasma spot (FDPS), created using the newly developed, instrument-free VLPlasma device, in identifying treatment failure at a VL threshold of 1,000 copies/ml in fresh plasma. Performance was compared with that of the conventional dried blood spot (DBS). Venous blood samples from 201 people living with HIV and attending an infectious disease clinic in Malaysia were collected, and HIV VL was quantified using fresh plasma (the reference standard), FDPS, and DBS specimens. VL testing was done using the Roche Cobas AmpliPrep/Cobas TaqMan v2.0 assay. At a threshold of 1,000 copies/ml, the diagnostic performance of the FDPS was superior (sensitivity, 100% [95% confidence interval {CI}, 89.1 to 100%]; specificity, 100% [95% CI, 97.8 to 100%]) to that of the DBS (sensitivity, 100% [95% CI, 89.4 to 100%]; specificity, 36.8% [95% CI, 29.4 to 44.7%]) (P < 0.001). A stronger correlation was observed between the FDPS VL and the plasma VL (r = 0.94; P < 0.001) than between the DBS VL and the plasma VL (r = 0.85; P < 0.001). The mean difference in VL measures between the FDPS and plasma (plasma VL minus FDPS VL) was 0.127 log(10) copies/ml (standard deviation [SD], 0.32), in contrast to –0.95 log(10) copies/ml (SD, 0.84) between the DBS and plasma. HIV VL measurement using the FDPS outperformed that with the DBS in identifying treatment failure at a threshold of 1,000 copies/ml and compared well with the quantification of VL in plasma. The FDPS can be an attractive alternative to fresh plasma for improving access to HIV VL monitoring among people living with HIV on ART in LMICs. American Society for Microbiology 2019-03-28 /pmc/articles/PMC6440787/ /pubmed/30700508 http://dx.doi.org/10.1128/JCM.01683-18 Text en Copyright © 2019 Pham et al. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Immunoassays
Pham, Minh D.
Haile, Berhan A.
Azwa, Iskandar
Kamarulzaman, Adeeba
Raman, Nishaan
Saeidi, Alireza
Kahar Bador, Maria
Tan, Margaret
Zhu, Jiawei
Feng, Yi
Elliott, Julian H.
Garcia, Mary L.
Li, Fan
Crowe, Suzanne M.
Luchters, Stanley
Anderson, David A.
Performance of a Novel Low-Cost, Instrument-Free Plasma Separation Device for HIV Viral Load Quantification and Determination of Treatment Failure in People Living with HIV in Malaysia: a Diagnostic Accuracy Study
title Performance of a Novel Low-Cost, Instrument-Free Plasma Separation Device for HIV Viral Load Quantification and Determination of Treatment Failure in People Living with HIV in Malaysia: a Diagnostic Accuracy Study
title_full Performance of a Novel Low-Cost, Instrument-Free Plasma Separation Device for HIV Viral Load Quantification and Determination of Treatment Failure in People Living with HIV in Malaysia: a Diagnostic Accuracy Study
title_fullStr Performance of a Novel Low-Cost, Instrument-Free Plasma Separation Device for HIV Viral Load Quantification and Determination of Treatment Failure in People Living with HIV in Malaysia: a Diagnostic Accuracy Study
title_full_unstemmed Performance of a Novel Low-Cost, Instrument-Free Plasma Separation Device for HIV Viral Load Quantification and Determination of Treatment Failure in People Living with HIV in Malaysia: a Diagnostic Accuracy Study
title_short Performance of a Novel Low-Cost, Instrument-Free Plasma Separation Device for HIV Viral Load Quantification and Determination of Treatment Failure in People Living with HIV in Malaysia: a Diagnostic Accuracy Study
title_sort performance of a novel low-cost, instrument-free plasma separation device for hiv viral load quantification and determination of treatment failure in people living with hiv in malaysia: a diagnostic accuracy study
topic Immunoassays
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6440787/
https://www.ncbi.nlm.nih.gov/pubmed/30700508
http://dx.doi.org/10.1128/JCM.01683-18
work_keys_str_mv AT phamminhd performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT haileberhana performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT azwaiskandar performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT kamarulzamanadeeba performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT ramannishaan performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT saeidialireza performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT kaharbadormaria performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT tanmargaret performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT zhujiawei performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT fengyi performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT elliottjulianh performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT garciamaryl performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT lifan performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT crowesuzannem performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT luchtersstanley performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy
AT andersondavida performanceofanovellowcostinstrumentfreeplasmaseparationdeviceforhivviralloadquantificationanddeterminationoftreatmentfailureinpeoplelivingwithhivinmalaysiaadiagnosticaccuracystudy