Cargando…

The gracilis tendon autograft is a safe choice for orthopedic reconstructive procedures: a consecutive case series studying the effects of tendon harvesting

BACKGROUND: The gracilis tendon is commonly used as an autograft to reconstruct torn tendons or ligaments in many parts of the body. Little is known about the subjective and functional outcome after gracilis tendon harvest. The aim of this study was to evaluate the outcome of the donor leg in patien...

Descripción completa

Detalles Bibliográficos
Autores principales: Nordin, Jonas S., Olsson, Ola, Lunsjö, Karl
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6441161/
https://www.ncbi.nlm.nih.gov/pubmed/30927929
http://dx.doi.org/10.1186/s12891-019-2520-5
_version_ 1783407505509974016
author Nordin, Jonas S.
Olsson, Ola
Lunsjö, Karl
author_facet Nordin, Jonas S.
Olsson, Ola
Lunsjö, Karl
author_sort Nordin, Jonas S.
collection PubMed
description BACKGROUND: The gracilis tendon is commonly used as an autograft to reconstruct torn tendons or ligaments in many parts of the body. Little is known about the subjective and functional outcome after gracilis tendon harvest. The aim of this study was to evaluate the outcome of the donor leg in patients undergoing such surgery. METHODS: Patients with chronic acromioclavicular joint dislocations undergoing coracoclavicular ligament reconstructions using autogenous gracilis tendon grafts were eligible for this study. The graft harvesting procedure was carried out in a standard fashion using a tendon stripper. Knee injury and Osteoarthritis Outcome Score (KOOS) were collected preoperatively and after 12 months. The first 5 patients were included retrospectively and lacked preoperative data, for these patients age- and gender matched normative KOOS scores were used as baseline values. Isometric knee flexor strength in 60° and 90° degrees of flexion was measured at final follow up at a median of 26 (14–56) months postoperatively with the non-operated leg used as reference. RESULTS: Twenty four patients were eligible for the study and 2 were excluded. The 22 patients available for analysis had a mean age of 44 (22–62) years at the time of surgery and 4 were women. There was no statistically significant change in KOOS 12 months postoperatively compared to baseline values but the patients were weaker in knee flexion in the operated leg compared to the non-operated one. CONCLUSIONS: Gracilis tendon harvesting results in a weakness of knee flexion but does not impair subjective knee function and is a procedure that can be recommended when an autogenous tendon graft is needed.
format Online
Article
Text
id pubmed-6441161
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-64411612019-04-11 The gracilis tendon autograft is a safe choice for orthopedic reconstructive procedures: a consecutive case series studying the effects of tendon harvesting Nordin, Jonas S. Olsson, Ola Lunsjö, Karl BMC Musculoskelet Disord Research Article BACKGROUND: The gracilis tendon is commonly used as an autograft to reconstruct torn tendons or ligaments in many parts of the body. Little is known about the subjective and functional outcome after gracilis tendon harvest. The aim of this study was to evaluate the outcome of the donor leg in patients undergoing such surgery. METHODS: Patients with chronic acromioclavicular joint dislocations undergoing coracoclavicular ligament reconstructions using autogenous gracilis tendon grafts were eligible for this study. The graft harvesting procedure was carried out in a standard fashion using a tendon stripper. Knee injury and Osteoarthritis Outcome Score (KOOS) were collected preoperatively and after 12 months. The first 5 patients were included retrospectively and lacked preoperative data, for these patients age- and gender matched normative KOOS scores were used as baseline values. Isometric knee flexor strength in 60° and 90° degrees of flexion was measured at final follow up at a median of 26 (14–56) months postoperatively with the non-operated leg used as reference. RESULTS: Twenty four patients were eligible for the study and 2 were excluded. The 22 patients available for analysis had a mean age of 44 (22–62) years at the time of surgery and 4 were women. There was no statistically significant change in KOOS 12 months postoperatively compared to baseline values but the patients were weaker in knee flexion in the operated leg compared to the non-operated one. CONCLUSIONS: Gracilis tendon harvesting results in a weakness of knee flexion but does not impair subjective knee function and is a procedure that can be recommended when an autogenous tendon graft is needed. BioMed Central 2019-03-30 /pmc/articles/PMC6441161/ /pubmed/30927929 http://dx.doi.org/10.1186/s12891-019-2520-5 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Nordin, Jonas S.
Olsson, Ola
Lunsjö, Karl
The gracilis tendon autograft is a safe choice for orthopedic reconstructive procedures: a consecutive case series studying the effects of tendon harvesting
title The gracilis tendon autograft is a safe choice for orthopedic reconstructive procedures: a consecutive case series studying the effects of tendon harvesting
title_full The gracilis tendon autograft is a safe choice for orthopedic reconstructive procedures: a consecutive case series studying the effects of tendon harvesting
title_fullStr The gracilis tendon autograft is a safe choice for orthopedic reconstructive procedures: a consecutive case series studying the effects of tendon harvesting
title_full_unstemmed The gracilis tendon autograft is a safe choice for orthopedic reconstructive procedures: a consecutive case series studying the effects of tendon harvesting
title_short The gracilis tendon autograft is a safe choice for orthopedic reconstructive procedures: a consecutive case series studying the effects of tendon harvesting
title_sort gracilis tendon autograft is a safe choice for orthopedic reconstructive procedures: a consecutive case series studying the effects of tendon harvesting
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6441161/
https://www.ncbi.nlm.nih.gov/pubmed/30927929
http://dx.doi.org/10.1186/s12891-019-2520-5
work_keys_str_mv AT nordinjonass thegracilistendonautograftisasafechoicefororthopedicreconstructiveproceduresaconsecutivecaseseriesstudyingtheeffectsoftendonharvesting
AT olssonola thegracilistendonautograftisasafechoicefororthopedicreconstructiveproceduresaconsecutivecaseseriesstudyingtheeffectsoftendonharvesting
AT lunsjokarl thegracilistendonautograftisasafechoicefororthopedicreconstructiveproceduresaconsecutivecaseseriesstudyingtheeffectsoftendonharvesting
AT nordinjonass gracilistendonautograftisasafechoicefororthopedicreconstructiveproceduresaconsecutivecaseseriesstudyingtheeffectsoftendonharvesting
AT olssonola gracilistendonautograftisasafechoicefororthopedicreconstructiveproceduresaconsecutivecaseseriesstudyingtheeffectsoftendonharvesting
AT lunsjokarl gracilistendonautograftisasafechoicefororthopedicreconstructiveproceduresaconsecutivecaseseriesstudyingtheeffectsoftendonharvesting