Assessment of agreement and interchangeability between the TEG5000 and TEG6S thromboelastography haemostasis analysers: a prospective validation study
BACKGROUND: TEG6S® and TEG5000® (Haemonetics Corp, USA) are haemostasis analysers that measure viscoelasticity properties of whole blood. Both use different mechanisms to assess similar components of the coagulation process. The aim of this study was to assess agreement and interchangeability betwee...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6441230/ https://www.ncbi.nlm.nih.gov/pubmed/30927909 http://dx.doi.org/10.1186/s12871-019-0717-7 |
_version_ | 1783407521731444736 |
---|---|
author | Lloyd-Donald, P. Churilov, L. Zia, F. Bellomo, R. Hart, G. McCall, P. Mårtensson, J. Glassford, N. Weinberg, L. |
author_facet | Lloyd-Donald, P. Churilov, L. Zia, F. Bellomo, R. Hart, G. McCall, P. Mårtensson, J. Glassford, N. Weinberg, L. |
author_sort | Lloyd-Donald, P. |
collection | PubMed |
description | BACKGROUND: TEG6S® and TEG5000® (Haemonetics Corp, USA) are haemostasis analysers that measure viscoelasticity properties of whole blood. Both use different mechanisms to assess similar components of the coagulation process. The aim of this study was to assess agreement and interchangeability between the TEG6S and TEG5000 analysers. METHODS: 3.5 mL whole blood was collected from 25 adult patients in a tertiary intensive care unit (ICU). Analysis was performed using TEG6S and TEG5000 haemostatic platforms. Agreement between platforms was measured using Lin’s concordance coefficient (Lin’s CC), further validated using intraclass correlation coefficients and reduced major axis regression (RMAR). RESULTS: Sixteen (64%) patients were male; mean (range) age: 59yo (23–86). TEG6S and TEG5000 systems were broadly interchangeable. The majority of TEG variables demonstrated almost perfect or substantial agreement and minimal proportional bias (maximum amplitude demonstrated a fixed bias). LY30%, however, demonstrated poor agreement and a proportional bias. Lin’s CC coefficients (95% CI, RMAR slope, intercept) between TEG6S and TEG5000 variables were: R time: 0.78 (0.64–0.92, 0.76, 0.92); K time: 0.82 (0.69–0.94, 1.30, − 0.93); alpha angle: 0.79 (0.64–0.95, 1.04, − 1.43); maximum amplitude (MA): 0.90 (0.83–0.96, 0.99, − 5.0); LY30%: 0.34 (0.1–0.58, 0.43, 0.04). CONCLUSIONS: Adult patients with critical illness demonstrate almost perfect agreement in the R time and MA, substantial agreement in K time and alpha angle, but poor agreement in LY30%, as measured by the TEG6S and TEG5000 analysers. With the exception of LY30%, the TEG6S and TEG5000 platforms appear interchangeable. This has important implications for use in clinical practice and multi-site research programs. TRIAL REGISTRATION: ANZCRT number: 12617000062325, registered 12/Jan17. Retrospectively registered. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12871-019-0717-7) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6441230 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-64412302019-04-11 Assessment of agreement and interchangeability between the TEG5000 and TEG6S thromboelastography haemostasis analysers: a prospective validation study Lloyd-Donald, P. Churilov, L. Zia, F. Bellomo, R. Hart, G. McCall, P. Mårtensson, J. Glassford, N. Weinberg, L. BMC Anesthesiol Research Article BACKGROUND: TEG6S® and TEG5000® (Haemonetics Corp, USA) are haemostasis analysers that measure viscoelasticity properties of whole blood. Both use different mechanisms to assess similar components of the coagulation process. The aim of this study was to assess agreement and interchangeability between the TEG6S and TEG5000 analysers. METHODS: 3.5 mL whole blood was collected from 25 adult patients in a tertiary intensive care unit (ICU). Analysis was performed using TEG6S and TEG5000 haemostatic platforms. Agreement between platforms was measured using Lin’s concordance coefficient (Lin’s CC), further validated using intraclass correlation coefficients and reduced major axis regression (RMAR). RESULTS: Sixteen (64%) patients were male; mean (range) age: 59yo (23–86). TEG6S and TEG5000 systems were broadly interchangeable. The majority of TEG variables demonstrated almost perfect or substantial agreement and minimal proportional bias (maximum amplitude demonstrated a fixed bias). LY30%, however, demonstrated poor agreement and a proportional bias. Lin’s CC coefficients (95% CI, RMAR slope, intercept) between TEG6S and TEG5000 variables were: R time: 0.78 (0.64–0.92, 0.76, 0.92); K time: 0.82 (0.69–0.94, 1.30, − 0.93); alpha angle: 0.79 (0.64–0.95, 1.04, − 1.43); maximum amplitude (MA): 0.90 (0.83–0.96, 0.99, − 5.0); LY30%: 0.34 (0.1–0.58, 0.43, 0.04). CONCLUSIONS: Adult patients with critical illness demonstrate almost perfect agreement in the R time and MA, substantial agreement in K time and alpha angle, but poor agreement in LY30%, as measured by the TEG6S and TEG5000 analysers. With the exception of LY30%, the TEG6S and TEG5000 platforms appear interchangeable. This has important implications for use in clinical practice and multi-site research programs. TRIAL REGISTRATION: ANZCRT number: 12617000062325, registered 12/Jan17. Retrospectively registered. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12871-019-0717-7) contains supplementary material, which is available to authorized users. BioMed Central 2019-03-30 /pmc/articles/PMC6441230/ /pubmed/30927909 http://dx.doi.org/10.1186/s12871-019-0717-7 Text en © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Lloyd-Donald, P. Churilov, L. Zia, F. Bellomo, R. Hart, G. McCall, P. Mårtensson, J. Glassford, N. Weinberg, L. Assessment of agreement and interchangeability between the TEG5000 and TEG6S thromboelastography haemostasis analysers: a prospective validation study |
title | Assessment of agreement and interchangeability between the TEG5000 and TEG6S thromboelastography haemostasis analysers: a prospective validation study |
title_full | Assessment of agreement and interchangeability between the TEG5000 and TEG6S thromboelastography haemostasis analysers: a prospective validation study |
title_fullStr | Assessment of agreement and interchangeability between the TEG5000 and TEG6S thromboelastography haemostasis analysers: a prospective validation study |
title_full_unstemmed | Assessment of agreement and interchangeability between the TEG5000 and TEG6S thromboelastography haemostasis analysers: a prospective validation study |
title_short | Assessment of agreement and interchangeability between the TEG5000 and TEG6S thromboelastography haemostasis analysers: a prospective validation study |
title_sort | assessment of agreement and interchangeability between the teg5000 and teg6s thromboelastography haemostasis analysers: a prospective validation study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6441230/ https://www.ncbi.nlm.nih.gov/pubmed/30927909 http://dx.doi.org/10.1186/s12871-019-0717-7 |
work_keys_str_mv | AT lloyddonaldp assessmentofagreementandinterchangeabilitybetweentheteg5000andteg6sthromboelastographyhaemostasisanalysersaprospectivevalidationstudy AT churilovl assessmentofagreementandinterchangeabilitybetweentheteg5000andteg6sthromboelastographyhaemostasisanalysersaprospectivevalidationstudy AT ziaf assessmentofagreementandinterchangeabilitybetweentheteg5000andteg6sthromboelastographyhaemostasisanalysersaprospectivevalidationstudy AT bellomor assessmentofagreementandinterchangeabilitybetweentheteg5000andteg6sthromboelastographyhaemostasisanalysersaprospectivevalidationstudy AT hartg assessmentofagreementandinterchangeabilitybetweentheteg5000andteg6sthromboelastographyhaemostasisanalysersaprospectivevalidationstudy AT mccallp assessmentofagreementandinterchangeabilitybetweentheteg5000andteg6sthromboelastographyhaemostasisanalysersaprospectivevalidationstudy AT martenssonj assessmentofagreementandinterchangeabilitybetweentheteg5000andteg6sthromboelastographyhaemostasisanalysersaprospectivevalidationstudy AT glassfordn assessmentofagreementandinterchangeabilitybetweentheteg5000andteg6sthromboelastographyhaemostasisanalysersaprospectivevalidationstudy AT weinbergl assessmentofagreementandinterchangeabilitybetweentheteg5000andteg6sthromboelastographyhaemostasisanalysersaprospectivevalidationstudy |