Cargando…

Chronological low field magnetic resonance appearance of canine spinal epidural hemorrhage model

The magnetic resonance (MR) features of spinal epidural hemorrhage depending with the passage of time have a meaning in veterinary medicine. The aim of this study is to propose the characteristic MR image of spinal epidural hemorrhage using a lower field permanent magnet scanner in dogs. A total of...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeong, Jimo, Jung, Yechan, Cho, YoungKown, Lee, Kichang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Veterinary Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6441813/
https://www.ncbi.nlm.nih.gov/pubmed/30944530
http://dx.doi.org/10.4142/jvs.2019.20.e7
_version_ 1783407605516861440
author Jeong, Jimo
Jung, Yechan
Cho, YoungKown
Lee, Kichang
author_facet Jeong, Jimo
Jung, Yechan
Cho, YoungKown
Lee, Kichang
author_sort Jeong, Jimo
collection PubMed
description The magnetic resonance (MR) features of spinal epidural hemorrhage depending with the passage of time have a meaning in veterinary medicine. The aim of this study is to propose the characteristic MR image of spinal epidural hemorrhage using a lower field permanent magnet scanner in dogs. A total of 8 clinically normal beagle dogs, weighing about 9 kg, were allocated. After a baseline MR examination, spinal epidural hemorrhage was created. MR scanning was executed on days 1, 2, 3, 4, 5, 10, 15, 20, 25, and 30 using 0.25 Tesla low field MR. Transverse MR images were attained for image examination. T2W, T1W, fluid-attenuated inversion recovery (FLAIR), short tau inversion recovery (STIR), and T2(*)-GRE sequences were used. Images were compared subjectively for signal transition assessment. Spinal epidural hemorrhage models were produced positively in 8 dogs at the T12 to L2 region. Initially, the spinal cord and epidural lesions were hyper-intense on T2W and T1W images. On T2W, FLAIR and STIR images, the spinal cord lesion was steadily hyperintense. No significant and consistent hypointense signal indicating hemorrhage was seen on T2(*)-GRE images. This study result suggests that relatively consistent hyperinstensity on T2 and FLAIR is observed for 30 days, meanwhile T2(*)-GRE imaging is less useful in hemorrhage detection.
format Online
Article
Text
id pubmed-6441813
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society of Veterinary Science
record_format MEDLINE/PubMed
spelling pubmed-64418132019-04-03 Chronological low field magnetic resonance appearance of canine spinal epidural hemorrhage model Jeong, Jimo Jung, Yechan Cho, YoungKown Lee, Kichang J Vet Sci Original Article The magnetic resonance (MR) features of spinal epidural hemorrhage depending with the passage of time have a meaning in veterinary medicine. The aim of this study is to propose the characteristic MR image of spinal epidural hemorrhage using a lower field permanent magnet scanner in dogs. A total of 8 clinically normal beagle dogs, weighing about 9 kg, were allocated. After a baseline MR examination, spinal epidural hemorrhage was created. MR scanning was executed on days 1, 2, 3, 4, 5, 10, 15, 20, 25, and 30 using 0.25 Tesla low field MR. Transverse MR images were attained for image examination. T2W, T1W, fluid-attenuated inversion recovery (FLAIR), short tau inversion recovery (STIR), and T2(*)-GRE sequences were used. Images were compared subjectively for signal transition assessment. Spinal epidural hemorrhage models were produced positively in 8 dogs at the T12 to L2 region. Initially, the spinal cord and epidural lesions were hyper-intense on T2W and T1W images. On T2W, FLAIR and STIR images, the spinal cord lesion was steadily hyperintense. No significant and consistent hypointense signal indicating hemorrhage was seen on T2(*)-GRE images. This study result suggests that relatively consistent hyperinstensity on T2 and FLAIR is observed for 30 days, meanwhile T2(*)-GRE imaging is less useful in hemorrhage detection. The Korean Society of Veterinary Science 2019-03 2019-03-08 /pmc/articles/PMC6441813/ /pubmed/30944530 http://dx.doi.org/10.4142/jvs.2019.20.e7 Text en © 2019 The Korean Society of Veterinary Science https://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Jeong, Jimo
Jung, Yechan
Cho, YoungKown
Lee, Kichang
Chronological low field magnetic resonance appearance of canine spinal epidural hemorrhage model
title Chronological low field magnetic resonance appearance of canine spinal epidural hemorrhage model
title_full Chronological low field magnetic resonance appearance of canine spinal epidural hemorrhage model
title_fullStr Chronological low field magnetic resonance appearance of canine spinal epidural hemorrhage model
title_full_unstemmed Chronological low field magnetic resonance appearance of canine spinal epidural hemorrhage model
title_short Chronological low field magnetic resonance appearance of canine spinal epidural hemorrhage model
title_sort chronological low field magnetic resonance appearance of canine spinal epidural hemorrhage model
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6441813/
https://www.ncbi.nlm.nih.gov/pubmed/30944530
http://dx.doi.org/10.4142/jvs.2019.20.e7
work_keys_str_mv AT jeongjimo chronologicallowfieldmagneticresonanceappearanceofcaninespinalepiduralhemorrhagemodel
AT jungyechan chronologicallowfieldmagneticresonanceappearanceofcaninespinalepiduralhemorrhagemodel
AT choyoungkown chronologicallowfieldmagneticresonanceappearanceofcaninespinalepiduralhemorrhagemodel
AT leekichang chronologicallowfieldmagneticresonanceappearanceofcaninespinalepiduralhemorrhagemodel