Cargando…
International consensus statement on robotic hepatectomy surgery in 2018
The robotic surgical system has been applied in liver surgery. However, controversies concerns exist regarding a variety of factors including the safety, feasibility, efficacy, and cost-effectiveness of robotic surgery. To promote the development of robotic hepatectomy, this study aimed to evaluate...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6441912/ https://www.ncbi.nlm.nih.gov/pubmed/30948907 http://dx.doi.org/10.3748/wjg.v25.i12.1432 |
_version_ | 1783407623582777344 |
---|---|
author | Liu, Rong Wakabayashi, Go Kim, Hong-Jin Choi, Gi-Hong Yiengpruksawan, Anusak Fong, Yuman He, Jin Boggi, Ugo Troisi, Roberto I Efanov, Mikhail Azoulay, Daniel Panaro, Fabrizio Pessaux, Patrick Wang, Xiao-Ying Zhu, Ji-Ye Zhang, Shao-Geng Sun, Chuan-Dong Wu, Zheng Tao, Kai-Shan Yang, Ke-Hu Fan, Jia Chen, Xiao-Ping |
author_facet | Liu, Rong Wakabayashi, Go Kim, Hong-Jin Choi, Gi-Hong Yiengpruksawan, Anusak Fong, Yuman He, Jin Boggi, Ugo Troisi, Roberto I Efanov, Mikhail Azoulay, Daniel Panaro, Fabrizio Pessaux, Patrick Wang, Xiao-Ying Zhu, Ji-Ye Zhang, Shao-Geng Sun, Chuan-Dong Wu, Zheng Tao, Kai-Shan Yang, Ke-Hu Fan, Jia Chen, Xiao-Ping |
author_sort | Liu, Rong |
collection | PubMed |
description | The robotic surgical system has been applied in liver surgery. However, controversies concerns exist regarding a variety of factors including the safety, feasibility, efficacy, and cost-effectiveness of robotic surgery. To promote the development of robotic hepatectomy, this study aimed to evaluate the current status of robotic hepatectomy and provide sixty experts’ consensus and recommendations to promote its development. Based on the World Health Organization Handbook for Guideline Development, a Consensus Steering Group and a Consensus Development Group were established to determine the topics, prepare evidence-based documents, and generate recommendations. The GRADE Grid method and Delphi vote were used to formulate the recommendations. A total of 22 topics were prepared analyzed and widely discussed during the 4 meetings. Based on the published articles and expert panel opinion, 7 recommendations were generated by the GRADE method using an evidence-based method, which focused on the safety, feasibility, indication, techniques and cost-effectiveness of hepatectomy. Given that the current evidences were low to very low as evaluated by the GRADE method, further randomized-controlled trials are needed in the future to validate these recommendations. |
format | Online Article Text |
id | pubmed-6441912 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Baishideng Publishing Group Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-64419122019-04-04 International consensus statement on robotic hepatectomy surgery in 2018 Liu, Rong Wakabayashi, Go Kim, Hong-Jin Choi, Gi-Hong Yiengpruksawan, Anusak Fong, Yuman He, Jin Boggi, Ugo Troisi, Roberto I Efanov, Mikhail Azoulay, Daniel Panaro, Fabrizio Pessaux, Patrick Wang, Xiao-Ying Zhu, Ji-Ye Zhang, Shao-Geng Sun, Chuan-Dong Wu, Zheng Tao, Kai-Shan Yang, Ke-Hu Fan, Jia Chen, Xiao-Ping World J Gastroenterol Guidelines The robotic surgical system has been applied in liver surgery. However, controversies concerns exist regarding a variety of factors including the safety, feasibility, efficacy, and cost-effectiveness of robotic surgery. To promote the development of robotic hepatectomy, this study aimed to evaluate the current status of robotic hepatectomy and provide sixty experts’ consensus and recommendations to promote its development. Based on the World Health Organization Handbook for Guideline Development, a Consensus Steering Group and a Consensus Development Group were established to determine the topics, prepare evidence-based documents, and generate recommendations. The GRADE Grid method and Delphi vote were used to formulate the recommendations. A total of 22 topics were prepared analyzed and widely discussed during the 4 meetings. Based on the published articles and expert panel opinion, 7 recommendations were generated by the GRADE method using an evidence-based method, which focused on the safety, feasibility, indication, techniques and cost-effectiveness of hepatectomy. Given that the current evidences were low to very low as evaluated by the GRADE method, further randomized-controlled trials are needed in the future to validate these recommendations. Baishideng Publishing Group Inc 2019-03-28 2019-03-28 /pmc/articles/PMC6441912/ /pubmed/30948907 http://dx.doi.org/10.3748/wjg.v25.i12.1432 Text en ©The Author(s) 2019. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. |
spellingShingle | Guidelines Liu, Rong Wakabayashi, Go Kim, Hong-Jin Choi, Gi-Hong Yiengpruksawan, Anusak Fong, Yuman He, Jin Boggi, Ugo Troisi, Roberto I Efanov, Mikhail Azoulay, Daniel Panaro, Fabrizio Pessaux, Patrick Wang, Xiao-Ying Zhu, Ji-Ye Zhang, Shao-Geng Sun, Chuan-Dong Wu, Zheng Tao, Kai-Shan Yang, Ke-Hu Fan, Jia Chen, Xiao-Ping International consensus statement on robotic hepatectomy surgery in 2018 |
title | International consensus statement on robotic hepatectomy surgery in 2018 |
title_full | International consensus statement on robotic hepatectomy surgery in 2018 |
title_fullStr | International consensus statement on robotic hepatectomy surgery in 2018 |
title_full_unstemmed | International consensus statement on robotic hepatectomy surgery in 2018 |
title_short | International consensus statement on robotic hepatectomy surgery in 2018 |
title_sort | international consensus statement on robotic hepatectomy surgery in 2018 |
topic | Guidelines |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6441912/ https://www.ncbi.nlm.nih.gov/pubmed/30948907 http://dx.doi.org/10.3748/wjg.v25.i12.1432 |
work_keys_str_mv | AT liurong internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT wakabayashigo internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT kimhongjin internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT choigihong internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT yiengpruksawananusak internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT fongyuman internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT hejin internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT boggiugo internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT troisirobertoi internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT efanovmikhail internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT azoulaydaniel internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT panarofabrizio internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT pessauxpatrick internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT wangxiaoying internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT zhujiye internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT zhangshaogeng internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT sunchuandong internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT wuzheng internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT taokaishan internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT yangkehu internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT fanjia internationalconsensusstatementonrobotichepatectomysurgeryin2018 AT chenxiaoping internationalconsensusstatementonrobotichepatectomysurgeryin2018 |