Cargando…

Easy, reproducible extraperitoneal pelvic access for robot - assisted radical prostatectomy

Robot - assisted radical prostatectomy is commonly performed transperitoneally (tRARP), although the extraperitoneal (eRARP) approach is a safe and effective alternative that may be preferred in certain situations. We developed a novel method of direct access into the space of Retzius with a visual...

Descripción completa

Detalles Bibliográficos
Autores principales: Gorgen, Antonio Rebello Horta, Pavlovich, Christian P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Urologia 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6442130/
https://www.ncbi.nlm.nih.gov/pubmed/30088726
http://dx.doi.org/10.1590/S1677-5538.IBJU.2018.0175
_version_ 1783407652992188416
author Gorgen, Antonio Rebello Horta
Pavlovich, Christian P.
author_facet Gorgen, Antonio Rebello Horta
Pavlovich, Christian P.
author_sort Gorgen, Antonio Rebello Horta
collection PubMed
description Robot - assisted radical prostatectomy is commonly performed transperitoneally (tRARP), although the extraperitoneal (eRARP) approach is a safe and effective alternative that may be preferred in certain situations. We developed a novel method of direct access into the space of Retzius with a visual obturator port (Visiport™) for laparoscopic or robotic prostatectomy. We present an instructional video of extraperitoneal pelvic access for eRARP with both internal and external camera views. The patient is first placed in lithotomy and 15° Trendelenburg position. The camera is inserted infraumbilically and angled caudally. The pre-peritoneal space is accessed through the anterior rectus fascia using a Visiport™ (Covidien, $ 60 www.esutures.com), and the working space is developed with a kidney - shaped balloon OMSPDBS2™ (Covidien, $ 49 www.esutures.com). After the space is insufflated, subsequent trocars are angled in extraperitoneally under direct vision. The average time from incision to final port placement after a learning curve of about 50 cases is 8 minutes (IQR 7-10). We have performed over 1.000 cases using this technique and eRARP has become our procedure of choice. Our last 500 + cases were performed robotically. Approximately 10% of the time peritoneotomies were noted, but rarely did these require conversion to tRARP. There have been no bowel or other abdominal organ injuries, major vascular or other complications in any of these cases.
format Online
Article
Text
id pubmed-6442130
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Sociedade Brasileira de Urologia
record_format MEDLINE/PubMed
spelling pubmed-64421302019-04-05 Easy, reproducible extraperitoneal pelvic access for robot - assisted radical prostatectomy Gorgen, Antonio Rebello Horta Pavlovich, Christian P. Int Braz J Urol Video Section Robot - assisted radical prostatectomy is commonly performed transperitoneally (tRARP), although the extraperitoneal (eRARP) approach is a safe and effective alternative that may be preferred in certain situations. We developed a novel method of direct access into the space of Retzius with a visual obturator port (Visiport™) for laparoscopic or robotic prostatectomy. We present an instructional video of extraperitoneal pelvic access for eRARP with both internal and external camera views. The patient is first placed in lithotomy and 15° Trendelenburg position. The camera is inserted infraumbilically and angled caudally. The pre-peritoneal space is accessed through the anterior rectus fascia using a Visiport™ (Covidien, $ 60 www.esutures.com), and the working space is developed with a kidney - shaped balloon OMSPDBS2™ (Covidien, $ 49 www.esutures.com). After the space is insufflated, subsequent trocars are angled in extraperitoneally under direct vision. The average time from incision to final port placement after a learning curve of about 50 cases is 8 minutes (IQR 7-10). We have performed over 1.000 cases using this technique and eRARP has become our procedure of choice. Our last 500 + cases were performed robotically. Approximately 10% of the time peritoneotomies were noted, but rarely did these require conversion to tRARP. There have been no bowel or other abdominal organ injuries, major vascular or other complications in any of these cases. Sociedade Brasileira de Urologia 2019 /pmc/articles/PMC6442130/ /pubmed/30088726 http://dx.doi.org/10.1590/S1677-5538.IBJU.2018.0175 Text en https://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Video Section
Gorgen, Antonio Rebello Horta
Pavlovich, Christian P.
Easy, reproducible extraperitoneal pelvic access for robot - assisted radical prostatectomy
title Easy, reproducible extraperitoneal pelvic access for robot - assisted radical prostatectomy
title_full Easy, reproducible extraperitoneal pelvic access for robot - assisted radical prostatectomy
title_fullStr Easy, reproducible extraperitoneal pelvic access for robot - assisted radical prostatectomy
title_full_unstemmed Easy, reproducible extraperitoneal pelvic access for robot - assisted radical prostatectomy
title_short Easy, reproducible extraperitoneal pelvic access for robot - assisted radical prostatectomy
title_sort easy, reproducible extraperitoneal pelvic access for robot - assisted radical prostatectomy
topic Video Section
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6442130/
https://www.ncbi.nlm.nih.gov/pubmed/30088726
http://dx.doi.org/10.1590/S1677-5538.IBJU.2018.0175
work_keys_str_mv AT gorgenantoniorebellohorta easyreproducibleextraperitonealpelvicaccessforrobotassistedradicalprostatectomy
AT pavlovichchristianp easyreproducibleextraperitonealpelvicaccessforrobotassistedradicalprostatectomy