Inter-rater reliability of the radiographic assessment of simple bone cysts

PURPOSE: To develop and evaluate the reliability of an explicit set of parameters and criteria for simple bone cysts (SBCs) and evaluate the reliability of single versus serial chronological reading methods METHODS: Radiographic criteria were developed based on the literature and expert consensus. A...

Descripción completa

Detalles Bibliográficos
Autores principales: Cho, S., Yankanah, R., Babyn, P., Stimec, J., Doria, A. S., Stephens, D., Wright, J. G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Editorial Society of Bone & Joint Surgery 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6442510/
https://www.ncbi.nlm.nih.gov/pubmed/30996749
http://dx.doi.org/10.1302/1863-2548.13.180140
_version_ 1783407722200301568
author Cho, S.
Yankanah, R.
Babyn, P.
Stimec, J.
Doria, A. S.
Stephens, D.
Wright, J. G.
author_facet Cho, S.
Yankanah, R.
Babyn, P.
Stimec, J.
Doria, A. S.
Stephens, D.
Wright, J. G.
author_sort Cho, S.
collection PubMed
description PURPOSE: To develop and evaluate the reliability of an explicit set of parameters and criteria for simple bone cysts (SBCs) and evaluate the reliability of single versus serial chronological reading methods METHODS: Radiographic criteria were developed based on the literature and expert consensus. A single anteroposterior/lateral radiograph from 32 subjects with SBC were evaluated by three radiologists. A second reading was then conducted using revised criteria including a visual schematic. In the third reading the same images were assessed but radiologists had access to images from two additional time points. Inter-rater reliability was assessed after each reading using kappa (κ) and percentage agreement for categorical and binary parameters and intra-class correlation coefficient (ICC) for continuous parameters. RESULTS: Parameters that were revised with more explicit definitions including the visual schematic demonstrated consistent or improved inter-rater reliability with the exception of continuous cortical rim present and cyst location in the metaphysis and mid-diaphysis. Cortical rim displayed only slight reliability throughout (κ= -0.008 to 0.16). All other categorical parameters had a percentage agreement above 0.8 or a moderate (κ= 0.41 to 0.60), substantial (κ = 0.61 to 0.80) or almost perfect inter-rater reliability (κ = 0.81 to 1.0) in at least one reading. All continuous parameters demonstrated excellent inter-rater reliability (ICC > 0.75) in at least one reading with the exception of scalloping (ICC = 0.37 to 0.70). Inter-rater reliability values did not indicate an obviously superior method of assessment between single and serial chronological readings. CONCLUSION: Explicit criteria for SBC parameters used in their assessment demonstrated improved and substantial inter-rater reliability. Inter-rater reliability did not differ between single and serial chronological readings. LEVEL OF EVIDENCE: Not Applicable
format Online
Article
Text
id pubmed-6442510
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The British Editorial Society of Bone & Joint Surgery
record_format MEDLINE/PubMed
spelling pubmed-64425102019-04-17 Inter-rater reliability of the radiographic assessment of simple bone cysts Cho, S. Yankanah, R. Babyn, P. Stimec, J. Doria, A. S. Stephens, D. Wright, J. G. J Child Orthop Original Clinical Article PURPOSE: To develop and evaluate the reliability of an explicit set of parameters and criteria for simple bone cysts (SBCs) and evaluate the reliability of single versus serial chronological reading methods METHODS: Radiographic criteria were developed based on the literature and expert consensus. A single anteroposterior/lateral radiograph from 32 subjects with SBC were evaluated by three radiologists. A second reading was then conducted using revised criteria including a visual schematic. In the third reading the same images were assessed but radiologists had access to images from two additional time points. Inter-rater reliability was assessed after each reading using kappa (κ) and percentage agreement for categorical and binary parameters and intra-class correlation coefficient (ICC) for continuous parameters. RESULTS: Parameters that were revised with more explicit definitions including the visual schematic demonstrated consistent or improved inter-rater reliability with the exception of continuous cortical rim present and cyst location in the metaphysis and mid-diaphysis. Cortical rim displayed only slight reliability throughout (κ= -0.008 to 0.16). All other categorical parameters had a percentage agreement above 0.8 or a moderate (κ= 0.41 to 0.60), substantial (κ = 0.61 to 0.80) or almost perfect inter-rater reliability (κ = 0.81 to 1.0) in at least one reading. All continuous parameters demonstrated excellent inter-rater reliability (ICC > 0.75) in at least one reading with the exception of scalloping (ICC = 0.37 to 0.70). Inter-rater reliability values did not indicate an obviously superior method of assessment between single and serial chronological readings. CONCLUSION: Explicit criteria for SBC parameters used in their assessment demonstrated improved and substantial inter-rater reliability. Inter-rater reliability did not differ between single and serial chronological readings. LEVEL OF EVIDENCE: Not Applicable The British Editorial Society of Bone & Joint Surgery 2019-04-01 /pmc/articles/PMC6442510/ /pubmed/30996749 http://dx.doi.org/10.1302/1863-2548.13.180140 Text en Copyright © 2019, The author(s) http://creativecommons.org/licenses/by-nc/4.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution-Non Commercial 4.0 International (CC BY-NC 4.0) licence (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed.
spellingShingle Original Clinical Article
Cho, S.
Yankanah, R.
Babyn, P.
Stimec, J.
Doria, A. S.
Stephens, D.
Wright, J. G.
Inter-rater reliability of the radiographic assessment of simple bone cysts
title Inter-rater reliability of the radiographic assessment of simple bone cysts
title_full Inter-rater reliability of the radiographic assessment of simple bone cysts
title_fullStr Inter-rater reliability of the radiographic assessment of simple bone cysts
title_full_unstemmed Inter-rater reliability of the radiographic assessment of simple bone cysts
title_short Inter-rater reliability of the radiographic assessment of simple bone cysts
title_sort inter-rater reliability of the radiographic assessment of simple bone cysts
topic Original Clinical Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6442510/
https://www.ncbi.nlm.nih.gov/pubmed/30996749
http://dx.doi.org/10.1302/1863-2548.13.180140
work_keys_str_mv AT chos interraterreliabilityoftheradiographicassessmentofsimplebonecysts
AT yankanahr interraterreliabilityoftheradiographicassessmentofsimplebonecysts
AT babynp interraterreliabilityoftheradiographicassessmentofsimplebonecysts
AT stimecj interraterreliabilityoftheradiographicassessmentofsimplebonecysts
AT doriaas interraterreliabilityoftheradiographicassessmentofsimplebonecysts
AT stephensd interraterreliabilityoftheradiographicassessmentofsimplebonecysts
AT wrightjg interraterreliabilityoftheradiographicassessmentofsimplebonecysts