Cargando…

Quality of spirometry tests and pulmonary function changes among industrial company workers in Iran: a two-year before-and-after study following an intensive training intervention

BACKGROUND: Quality improvement, standardisation of spirometry testing, and interpretation of results are critically important in the occupational setting. AIMS: To determine the quality of spirometry tests and pulmonary function changes in two consecutive years among the personnel of an industrial...

Descripción completa

Detalles Bibliográficos
Autores principales: Seyedmehdi, Seyed Mohammad, Attarchi, Mirsaeed, Yazdanparast, Taraneh, Lakeh, Maziar Moradi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6442756/
https://www.ncbi.nlm.nih.gov/pubmed/23443228
http://dx.doi.org/10.4104/pcrj.2013.00018
_version_ 1783407750993149952
author Seyedmehdi, Seyed Mohammad
Attarchi, Mirsaeed
Yazdanparast, Taraneh
Lakeh, Maziar Moradi
author_facet Seyedmehdi, Seyed Mohammad
Attarchi, Mirsaeed
Yazdanparast, Taraneh
Lakeh, Maziar Moradi
author_sort Seyedmehdi, Seyed Mohammad
collection PubMed
description BACKGROUND: Quality improvement, standardisation of spirometry testing, and interpretation of results are critically important in the occupational setting. AIMS: To determine the quality of spirometry tests and pulmonary function changes in two consecutive years among the personnel of an industrial company. METHODS: This study was performed in an oil refinery in Iran in 2011. Data on 1,004 male personnel were evaluated before and after a training course conducted according to the National Institute for Occupational Safety and Health guidelines. American Thoracic Society/European Respiratory Society guidelines were used for assessment of the acceptability and repeatability criteria. RESULTS: The most common error in the first year of evaluation was forced vital capacity >6 seconds or a 1 second plateau. Acceptability and proper interpretation significantly improved after the course (p<0.05), but repeatability did not change significantly (p>0.05). CONCLUSIONS: The results of this study show that the validity and quality of spirometric tests conducted in the studied company in Iran were unacceptable, but these improved significantly after the training intervention. The study demonstrated the lack of a systematic guideline for conducting spirometry and interpreting the results in the occupational setting in Iran, and emphasises the need for a nationwide programme to improve the quality of spirometry tests in this setting.
format Online
Article
Text
id pubmed-6442756
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-64427562019-07-01 Quality of spirometry tests and pulmonary function changes among industrial company workers in Iran: a two-year before-and-after study following an intensive training intervention Seyedmehdi, Seyed Mohammad Attarchi, Mirsaeed Yazdanparast, Taraneh Lakeh, Maziar Moradi Prim Care Respir J Research Paper BACKGROUND: Quality improvement, standardisation of spirometry testing, and interpretation of results are critically important in the occupational setting. AIMS: To determine the quality of spirometry tests and pulmonary function changes in two consecutive years among the personnel of an industrial company. METHODS: This study was performed in an oil refinery in Iran in 2011. Data on 1,004 male personnel were evaluated before and after a training course conducted according to the National Institute for Occupational Safety and Health guidelines. American Thoracic Society/European Respiratory Society guidelines were used for assessment of the acceptability and repeatability criteria. RESULTS: The most common error in the first year of evaluation was forced vital capacity >6 seconds or a 1 second plateau. Acceptability and proper interpretation significantly improved after the course (p<0.05), but repeatability did not change significantly (p>0.05). CONCLUSIONS: The results of this study show that the validity and quality of spirometric tests conducted in the studied company in Iran were unacceptable, but these improved significantly after the training intervention. The study demonstrated the lack of a systematic guideline for conducting spirometry and interpreting the results in the occupational setting in Iran, and emphasises the need for a nationwide programme to improve the quality of spirometry tests in this setting. Nature Publishing Group 2013-03 2013-02-25 /pmc/articles/PMC6442756/ /pubmed/23443228 http://dx.doi.org/10.4104/pcrj.2013.00018 Text en Copyright © 2013 Primary Care Respiratory Society UK
spellingShingle Research Paper
Seyedmehdi, Seyed Mohammad
Attarchi, Mirsaeed
Yazdanparast, Taraneh
Lakeh, Maziar Moradi
Quality of spirometry tests and pulmonary function changes among industrial company workers in Iran: a two-year before-and-after study following an intensive training intervention
title Quality of spirometry tests and pulmonary function changes among industrial company workers in Iran: a two-year before-and-after study following an intensive training intervention
title_full Quality of spirometry tests and pulmonary function changes among industrial company workers in Iran: a two-year before-and-after study following an intensive training intervention
title_fullStr Quality of spirometry tests and pulmonary function changes among industrial company workers in Iran: a two-year before-and-after study following an intensive training intervention
title_full_unstemmed Quality of spirometry tests and pulmonary function changes among industrial company workers in Iran: a two-year before-and-after study following an intensive training intervention
title_short Quality of spirometry tests and pulmonary function changes among industrial company workers in Iran: a two-year before-and-after study following an intensive training intervention
title_sort quality of spirometry tests and pulmonary function changes among industrial company workers in iran: a two-year before-and-after study following an intensive training intervention
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6442756/
https://www.ncbi.nlm.nih.gov/pubmed/23443228
http://dx.doi.org/10.4104/pcrj.2013.00018
work_keys_str_mv AT seyedmehdiseyedmohammad qualityofspirometrytestsandpulmonaryfunctionchangesamongindustrialcompanyworkersiniranatwoyearbeforeandafterstudyfollowinganintensivetrainingintervention
AT attarchimirsaeed qualityofspirometrytestsandpulmonaryfunctionchangesamongindustrialcompanyworkersiniranatwoyearbeforeandafterstudyfollowinganintensivetrainingintervention
AT yazdanparasttaraneh qualityofspirometrytestsandpulmonaryfunctionchangesamongindustrialcompanyworkersiniranatwoyearbeforeandafterstudyfollowinganintensivetrainingintervention
AT lakehmaziarmoradi qualityofspirometrytestsandpulmonaryfunctionchangesamongindustrialcompanyworkersiniranatwoyearbeforeandafterstudyfollowinganintensivetrainingintervention