Cargando…
Intracoronary near-infrared spectroscopy and the risk of future cardiovascular events
OBJECTIVES: The objectives of this study were to investigate if findings by intracoronary near-infrared spectroscopy (NIRS) and intravascular ultrasound (IVUS) are associated with future cardiovascular events and if NIRS can differentiate culprit from non-culprit segments in patients with coronary a...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6443121/ https://www.ncbi.nlm.nih.gov/pubmed/30997122 http://dx.doi.org/10.1136/openhrt-2018-000917 |
Sumario: | OBJECTIVES: The objectives of this study were to investigate if findings by intracoronary near-infrared spectroscopy (NIRS) and intravascular ultrasound (IVUS) are associated with future cardiovascular events and if NIRS can differentiate culprit from non-culprit segments in patients with coronary artery disease. METHODS: The study included 144 patients with coronary artery disease undergoing percutaneous coronary intervention and combined NIRS-IVUS imaging at two Swedish hospitals. The NIRS-derived lipid core burden index (LCBI), the 4 mm segment with maximum LCBI (MaxLCBI(4mm)) and the IVUS-derived maximum plaque burden (MaxPB) were analysed within the culprit segment and continuous 10 mm non-culprit segments of the index culprit vessels. The association with future major adverse cardiovascular and cerebrovascular events (MACCE), defined as all-cause mortality, acute coronary syndrome requiring revascularisation and cerebrovascular events during follow-up was evaluated using multivariable Cox regressions. A receiver operating characteristic (ROC) analysis was performed to test the ability of NIRS to discriminate culprit against non-culprit segments. RESULTS: A non-culprit maxLCBI(4mm) ≥400 (HR: 3.67, 95% CI 1.46 to 9.23, p=0.006) and a non-culprit LCBI ≥ median (HR: 3.08, 95% CI 1.11 to 8.56, p=0.031) were both significantly associated with MACCE, whereas a non-culprit MaxPB ≥70% (HR: 0.61, 95% CI 0.08 to 4.59, p=0.63) was not. The culprit segments had larger lipid cores compared with non-culprit segments (MaxLCBI(4mm) 425 vs 74, p<0.001), and the ROC analysis showed that NIRS can differentiate culprit against non-culprit segments (c-statistics: 0.85, 95% CI 0.81 to 0.89). CONCLUSION: A maxLCBI(4mm) ≥400 and LCBI ≥ median, assessed by NIRS in non-culprit segments of a culprit artery, were significantly associated with patient-level MACCE. NIRS furthermore adequately discriminated culprit against non-culprit segments in patients with coronary disease. |
---|