Cargando…

Analytical performance of a single epitope B-type natriuretic peptide sandwich immunoassay on the Minicare platform for point-of-care diagnostics

Point-of-care B-type natriuretic peptide (BNP) testing with adequate analytical performance has the potential to improve patient flow and provide primary care givers with easy-to-use advanced diagnostic tools in the management of heart failure. We present the analytical evaluation of the Minicare BN...

Descripción completa

Detalles Bibliográficos
Autores principales: Reenen, Alexander van, Berger, Mario, Moreau, Emmanuel, Bekx, Edwin, Bruinink, Tom, Kemper, Danielle, Lippen, Lian van, Weusten, Jos, Mrakovic, Anita, Michielsen, Etienne, Vissers, Joost, Theije, Femke de, Nieuwenhuis, Jeroen, Semjonow, Veronique, Mair, Johannes
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6444177/
https://www.ncbi.nlm.nih.gov/pubmed/30984810
http://dx.doi.org/10.1016/j.plabm.2019.e00119
_version_ 1783407979813404672
author Reenen, Alexander van
Berger, Mario
Moreau, Emmanuel
Bekx, Edwin
Bruinink, Tom
Kemper, Danielle
Lippen, Lian van
Weusten, Jos
Mrakovic, Anita
Michielsen, Etienne
Vissers, Joost
Theije, Femke de
Nieuwenhuis, Jeroen
Semjonow, Veronique
Mair, Johannes
author_facet Reenen, Alexander van
Berger, Mario
Moreau, Emmanuel
Bekx, Edwin
Bruinink, Tom
Kemper, Danielle
Lippen, Lian van
Weusten, Jos
Mrakovic, Anita
Michielsen, Etienne
Vissers, Joost
Theije, Femke de
Nieuwenhuis, Jeroen
Semjonow, Veronique
Mair, Johannes
author_sort Reenen, Alexander van
collection PubMed
description Point-of-care B-type natriuretic peptide (BNP) testing with adequate analytical performance has the potential to improve patient flow and provide primary care givers with easy-to-use advanced diagnostic tools in the management of heart failure. We present the analytical evaluation of the Minicare BNP immunoassay under development on the Minicare I-20 platform for point-of-care testing. Analytical performance was evaluated using EDTA venous whole blood, EDTA plasma and capillary whole blood. Method comparison with a lab-testing system was performed using samples from 187 patients. Normal values were determined based on 160 healthy adults, aging from 19 to 70 years. Limit of blank (LoB), limit of detection (LoD) were determined to be 3.3 ng/L, 5.8 ng/L. Limit of quantitation (LoQ) in whole blood at 20% and 10% coefficient of variation (CV) was found < 9 ng/L and <30 ng/L respectively without significant differences between EDTA whole blood and EDTA plasma. Total CV was found to be from 6.7% to 9.7% for BNP concentrations between 92.6 and 3984 ng/L. The sample type comparison study demonstrated correlation coefficients between 0.97 and 0.99 with slopes between 1.03 and 1.09 between the different samples. Method comparison between Minicare BNP and Siemens ADVIA Centaur BNP demonstrated a correlation coefficient of 0.92 with a slope of 1.06. The 97.5% URL of a healthy population was calculated to be 72.6 ng/L. The Minicare BNP assay is a robust, easy-to-use and sensitive test for rapid determination of BNP concentrations that can be used in a near-patient setting.
format Online
Article
Text
id pubmed-6444177
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-64441772019-04-12 Analytical performance of a single epitope B-type natriuretic peptide sandwich immunoassay on the Minicare platform for point-of-care diagnostics Reenen, Alexander van Berger, Mario Moreau, Emmanuel Bekx, Edwin Bruinink, Tom Kemper, Danielle Lippen, Lian van Weusten, Jos Mrakovic, Anita Michielsen, Etienne Vissers, Joost Theije, Femke de Nieuwenhuis, Jeroen Semjonow, Veronique Mair, Johannes Pract Lab Med Article Point-of-care B-type natriuretic peptide (BNP) testing with adequate analytical performance has the potential to improve patient flow and provide primary care givers with easy-to-use advanced diagnostic tools in the management of heart failure. We present the analytical evaluation of the Minicare BNP immunoassay under development on the Minicare I-20 platform for point-of-care testing. Analytical performance was evaluated using EDTA venous whole blood, EDTA plasma and capillary whole blood. Method comparison with a lab-testing system was performed using samples from 187 patients. Normal values were determined based on 160 healthy adults, aging from 19 to 70 years. Limit of blank (LoB), limit of detection (LoD) were determined to be 3.3 ng/L, 5.8 ng/L. Limit of quantitation (LoQ) in whole blood at 20% and 10% coefficient of variation (CV) was found < 9 ng/L and <30 ng/L respectively without significant differences between EDTA whole blood and EDTA plasma. Total CV was found to be from 6.7% to 9.7% for BNP concentrations between 92.6 and 3984 ng/L. The sample type comparison study demonstrated correlation coefficients between 0.97 and 0.99 with slopes between 1.03 and 1.09 between the different samples. Method comparison between Minicare BNP and Siemens ADVIA Centaur BNP demonstrated a correlation coefficient of 0.92 with a slope of 1.06. The 97.5% URL of a healthy population was calculated to be 72.6 ng/L. The Minicare BNP assay is a robust, easy-to-use and sensitive test for rapid determination of BNP concentrations that can be used in a near-patient setting. Elsevier 2019-03-17 /pmc/articles/PMC6444177/ /pubmed/30984810 http://dx.doi.org/10.1016/j.plabm.2019.e00119 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Reenen, Alexander van
Berger, Mario
Moreau, Emmanuel
Bekx, Edwin
Bruinink, Tom
Kemper, Danielle
Lippen, Lian van
Weusten, Jos
Mrakovic, Anita
Michielsen, Etienne
Vissers, Joost
Theije, Femke de
Nieuwenhuis, Jeroen
Semjonow, Veronique
Mair, Johannes
Analytical performance of a single epitope B-type natriuretic peptide sandwich immunoassay on the Minicare platform for point-of-care diagnostics
title Analytical performance of a single epitope B-type natriuretic peptide sandwich immunoassay on the Minicare platform for point-of-care diagnostics
title_full Analytical performance of a single epitope B-type natriuretic peptide sandwich immunoassay on the Minicare platform for point-of-care diagnostics
title_fullStr Analytical performance of a single epitope B-type natriuretic peptide sandwich immunoassay on the Minicare platform for point-of-care diagnostics
title_full_unstemmed Analytical performance of a single epitope B-type natriuretic peptide sandwich immunoassay on the Minicare platform for point-of-care diagnostics
title_short Analytical performance of a single epitope B-type natriuretic peptide sandwich immunoassay on the Minicare platform for point-of-care diagnostics
title_sort analytical performance of a single epitope b-type natriuretic peptide sandwich immunoassay on the minicare platform for point-of-care diagnostics
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6444177/
https://www.ncbi.nlm.nih.gov/pubmed/30984810
http://dx.doi.org/10.1016/j.plabm.2019.e00119
work_keys_str_mv AT reenenalexandervan analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT bergermario analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT moreauemmanuel analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT bekxedwin analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT bruininktom analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT kemperdanielle analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT lippenlianvan analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT weustenjos analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT mrakovicanita analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT michielsenetienne analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT vissersjoost analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT theijefemkede analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT nieuwenhuisjeroen analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT semjonowveronique analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics
AT mairjohannes analyticalperformanceofasingleepitopebtypenatriureticpeptidesandwichimmunoassayontheminicareplatformforpointofcarediagnostics