Cargando…
Graphene–aluminum nitride NEMS resonant infrared detector
The use of micro-/nanoelectromechanical resonators for the room temperature detection of electromagnetic radiation at infrared frequencies has recently been investigated, showing thermal detection capabilities that could potentially outperform conventional microbolometers. The scaling of the device...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6444720/ https://www.ncbi.nlm.nih.gov/pubmed/31057826 http://dx.doi.org/10.1038/micronano.2016.26 |
_version_ | 1783408072714092544 |
---|---|
author | Qian, Zhenyun Hui, Yu Liu, Fangze Kang, Sungho Kar, Swastik Rinaldi, Matteo |
author_facet | Qian, Zhenyun Hui, Yu Liu, Fangze Kang, Sungho Kar, Swastik Rinaldi, Matteo |
author_sort | Qian, Zhenyun |
collection | PubMed |
description | The use of micro-/nanoelectromechanical resonators for the room temperature detection of electromagnetic radiation at infrared frequencies has recently been investigated, showing thermal detection capabilities that could potentially outperform conventional microbolometers. The scaling of the device thickness in the nanometer range and the achievement of high infrared absorption in such a subwavelength thickness, without sacrificing the electromechanical performance, are the two key challenges for the implementation of fast, high-resolution micro-/nanoelectromechanical resonant infrared detectors. In this paper, we show that by using a virtually massless, high-electrical-conductivity, and transparent graphene electrode, floating at the van der Waals separation of a few angstroms from a piezoelectric aluminum nitride nanoplate, it is possible to implement ultrathin (460 nm) piezoelectric nanomechanical resonant structures with improved electromechanical performance (>50% improved frequency×quality factor) and infrared detection capabilities (>100× improved infrared absorptance) compared with metal-electrode counterparts, despite their reduced volumes. The intrinsic infrared absorption capabilities of a submicron thin graphene–aluminum nitride plate backed with a metal electrode are investigated for the first time and exploited for the first experimental demonstration of a piezoelectric nanoelectromechanical resonant thermal detector with enhanced infrared absorptance in a reduced volume. Moreover, the combination of electromagnetic and piezoelectric resonances provided by the same graphene–aluminum nitride-metal stack allows the proposed device to selectively detect short-wavelength infrared radiation (by tailoring the thickness of aluminum nitride) with unprecedented electromechanical performance and thermal capabilities. These attributes potentially lead to the development of uncooled infrared detectors suitable for the implementation of high performance, miniaturized and power-efficient multispectral infrared imaging systems. |
format | Online Article Text |
id | pubmed-6444720 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-64447202019-05-03 Graphene–aluminum nitride NEMS resonant infrared detector Qian, Zhenyun Hui, Yu Liu, Fangze Kang, Sungho Kar, Swastik Rinaldi, Matteo Microsyst Nanoeng Article The use of micro-/nanoelectromechanical resonators for the room temperature detection of electromagnetic radiation at infrared frequencies has recently been investigated, showing thermal detection capabilities that could potentially outperform conventional microbolometers. The scaling of the device thickness in the nanometer range and the achievement of high infrared absorption in such a subwavelength thickness, without sacrificing the electromechanical performance, are the two key challenges for the implementation of fast, high-resolution micro-/nanoelectromechanical resonant infrared detectors. In this paper, we show that by using a virtually massless, high-electrical-conductivity, and transparent graphene electrode, floating at the van der Waals separation of a few angstroms from a piezoelectric aluminum nitride nanoplate, it is possible to implement ultrathin (460 nm) piezoelectric nanomechanical resonant structures with improved electromechanical performance (>50% improved frequency×quality factor) and infrared detection capabilities (>100× improved infrared absorptance) compared with metal-electrode counterparts, despite their reduced volumes. The intrinsic infrared absorption capabilities of a submicron thin graphene–aluminum nitride plate backed with a metal electrode are investigated for the first time and exploited for the first experimental demonstration of a piezoelectric nanoelectromechanical resonant thermal detector with enhanced infrared absorptance in a reduced volume. Moreover, the combination of electromagnetic and piezoelectric resonances provided by the same graphene–aluminum nitride-metal stack allows the proposed device to selectively detect short-wavelength infrared radiation (by tailoring the thickness of aluminum nitride) with unprecedented electromechanical performance and thermal capabilities. These attributes potentially lead to the development of uncooled infrared detectors suitable for the implementation of high performance, miniaturized and power-efficient multispectral infrared imaging systems. Nature Publishing Group 2016-06-20 /pmc/articles/PMC6444720/ /pubmed/31057826 http://dx.doi.org/10.1038/micronano.2016.26 Text en Copyright © 2016 © 2016 Institute of Electronics, Chinese Academy of Sciences http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Qian, Zhenyun Hui, Yu Liu, Fangze Kang, Sungho Kar, Swastik Rinaldi, Matteo Graphene–aluminum nitride NEMS resonant infrared detector |
title | Graphene–aluminum nitride NEMS resonant infrared detector |
title_full | Graphene–aluminum nitride NEMS resonant infrared detector |
title_fullStr | Graphene–aluminum nitride NEMS resonant infrared detector |
title_full_unstemmed | Graphene–aluminum nitride NEMS resonant infrared detector |
title_short | Graphene–aluminum nitride NEMS resonant infrared detector |
title_sort | graphene–aluminum nitride nems resonant infrared detector |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6444720/ https://www.ncbi.nlm.nih.gov/pubmed/31057826 http://dx.doi.org/10.1038/micronano.2016.26 |
work_keys_str_mv | AT qianzhenyun graphenealuminumnitridenemsresonantinfrareddetector AT huiyu graphenealuminumnitridenemsresonantinfrareddetector AT liufangze graphenealuminumnitridenemsresonantinfrareddetector AT kangsungho graphenealuminumnitridenemsresonantinfrareddetector AT karswastik graphenealuminumnitridenemsresonantinfrareddetector AT rinaldimatteo graphenealuminumnitridenemsresonantinfrareddetector |