Cargando…

Evaluation and Comparison of Fentanyl versus Nalbuphine for Attenuation of Hemodynamic Response to Laryngoscopy and Endotracheal Intubation in General Anesthesia

BACKGROUND: General anesthesia administration involves laryngoscopy and endotracheal intubation which are associated with the pressor response and can lead to tachycardia, hypertension, and arrhythmias, which can be deleterious in compromised patients and hence, this response needs to be suppressed....

Descripción completa

Detalles Bibliográficos
Autores principales: Khanday, Shoiab Bashir, Mir, Aabid Hussain, Sofi, Khalid Pervaiz, Lone, Abdul Qayoom, Shah, Areeba Noor
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6444961/
https://www.ncbi.nlm.nih.gov/pubmed/31031490
http://dx.doi.org/10.4103/aer.AER_16_19
_version_ 1783408108779864064
author Khanday, Shoiab Bashir
Mir, Aabid Hussain
Sofi, Khalid Pervaiz
Lone, Abdul Qayoom
Shah, Areeba Noor
author_facet Khanday, Shoiab Bashir
Mir, Aabid Hussain
Sofi, Khalid Pervaiz
Lone, Abdul Qayoom
Shah, Areeba Noor
author_sort Khanday, Shoiab Bashir
collection PubMed
description BACKGROUND: General anesthesia administration involves laryngoscopy and endotracheal intubation which are associated with the pressor response and can lead to tachycardia, hypertension, and arrhythmias, which can be deleterious in compromised patients and hence, this response needs to be suppressed. AIMS: The aim of the study is to compare the effectiveness of intravenous (i.v) fentanyl and nalbuphine on the suppression of hemodynamic response in patients undergoing surgery under general anesthesia. SETTING AND DESIGN: This prospective comparative study was conducted in the department of anesthesiology of a tertiary care center, and patients posted for elective surgery under general anesthesia were included. METHODS: A total of 100 patients of either sex in the age group of 20–50 years, belonging to the American Society of Anesthesiologists physical status classes I and II undergoing surgery under general anesthesia, were divided into two groups: Group N (n = 50) – who received injection nalbuphine 0.2 mg/kg diluted in 10 mL normal saline i.v and Group F (n = 50) – who received injection fentanyl 2 μg/kg diluted in 10 mL of normal saline i.v over 1 min, 5 min prior to intubation. Technique of anesthesia was standardized for all the patients in the study. Heart rate (HR), blood pressure (systolic, diastolic, and mean arterial pressure [SBP, DBP, and MAP]), and oxygen saturation were recorded at baseline, induction, and at 1, 3, 5, and 10 min after intubation. STATISTICAL ANALYSIS: Descriptive statistics were done using mean with standard deviation for quantitative variables, and categorical variables were presented in frequencies along with respective percentages. The statistical comparisons for quantitative variables were done using Student's t-test and for categorical variables, Chi-square was used according to the data. All statistical analyses were performed using SPSS software (Version 22, SPSS Inc., Chicago, IL, USA). All analyses were two tailed, and results were discussed on 5% level of significance, i.e., P < 0.05 was considered statistically significant. RESULTS: The demographic characteristics were comparable in both groups. HR was statistically insignificant between the two groups at all intervals. Comparing SBP, DBP, and MAP between the two groups, there was a significant increase in nalbuphine group than fentanyl group postintubation and was statistically significant at all intervals of time. Maximum rise in SBP, DBP, and MAP was 5.49%, 6.03%, and 5.80% for fentanyl group and 12.88%, 9.37%, and 10.86% for nalbuphine group, respectively. Comparison of oxygen saturation in two groups was statistically insignificant. CONCLUSION: Fentanyl is better than nalbuphine in blunting the pressor response of laryngoscopy and endotracheal intubation.
format Online
Article
Text
id pubmed-6444961
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-64449612019-04-26 Evaluation and Comparison of Fentanyl versus Nalbuphine for Attenuation of Hemodynamic Response to Laryngoscopy and Endotracheal Intubation in General Anesthesia Khanday, Shoiab Bashir Mir, Aabid Hussain Sofi, Khalid Pervaiz Lone, Abdul Qayoom Shah, Areeba Noor Anesth Essays Res Original Article BACKGROUND: General anesthesia administration involves laryngoscopy and endotracheal intubation which are associated with the pressor response and can lead to tachycardia, hypertension, and arrhythmias, which can be deleterious in compromised patients and hence, this response needs to be suppressed. AIMS: The aim of the study is to compare the effectiveness of intravenous (i.v) fentanyl and nalbuphine on the suppression of hemodynamic response in patients undergoing surgery under general anesthesia. SETTING AND DESIGN: This prospective comparative study was conducted in the department of anesthesiology of a tertiary care center, and patients posted for elective surgery under general anesthesia were included. METHODS: A total of 100 patients of either sex in the age group of 20–50 years, belonging to the American Society of Anesthesiologists physical status classes I and II undergoing surgery under general anesthesia, were divided into two groups: Group N (n = 50) – who received injection nalbuphine 0.2 mg/kg diluted in 10 mL normal saline i.v and Group F (n = 50) – who received injection fentanyl 2 μg/kg diluted in 10 mL of normal saline i.v over 1 min, 5 min prior to intubation. Technique of anesthesia was standardized for all the patients in the study. Heart rate (HR), blood pressure (systolic, diastolic, and mean arterial pressure [SBP, DBP, and MAP]), and oxygen saturation were recorded at baseline, induction, and at 1, 3, 5, and 10 min after intubation. STATISTICAL ANALYSIS: Descriptive statistics were done using mean with standard deviation for quantitative variables, and categorical variables were presented in frequencies along with respective percentages. The statistical comparisons for quantitative variables were done using Student's t-test and for categorical variables, Chi-square was used according to the data. All statistical analyses were performed using SPSS software (Version 22, SPSS Inc., Chicago, IL, USA). All analyses were two tailed, and results were discussed on 5% level of significance, i.e., P < 0.05 was considered statistically significant. RESULTS: The demographic characteristics were comparable in both groups. HR was statistically insignificant between the two groups at all intervals. Comparing SBP, DBP, and MAP between the two groups, there was a significant increase in nalbuphine group than fentanyl group postintubation and was statistically significant at all intervals of time. Maximum rise in SBP, DBP, and MAP was 5.49%, 6.03%, and 5.80% for fentanyl group and 12.88%, 9.37%, and 10.86% for nalbuphine group, respectively. Comparison of oxygen saturation in two groups was statistically insignificant. CONCLUSION: Fentanyl is better than nalbuphine in blunting the pressor response of laryngoscopy and endotracheal intubation. Wolters Kluwer - Medknow 2019 /pmc/articles/PMC6444961/ /pubmed/31031490 http://dx.doi.org/10.4103/aer.AER_16_19 Text en Copyright: © 2019 Anesthesia: Essays and Researches http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Khanday, Shoiab Bashir
Mir, Aabid Hussain
Sofi, Khalid Pervaiz
Lone, Abdul Qayoom
Shah, Areeba Noor
Evaluation and Comparison of Fentanyl versus Nalbuphine for Attenuation of Hemodynamic Response to Laryngoscopy and Endotracheal Intubation in General Anesthesia
title Evaluation and Comparison of Fentanyl versus Nalbuphine for Attenuation of Hemodynamic Response to Laryngoscopy and Endotracheal Intubation in General Anesthesia
title_full Evaluation and Comparison of Fentanyl versus Nalbuphine for Attenuation of Hemodynamic Response to Laryngoscopy and Endotracheal Intubation in General Anesthesia
title_fullStr Evaluation and Comparison of Fentanyl versus Nalbuphine for Attenuation of Hemodynamic Response to Laryngoscopy and Endotracheal Intubation in General Anesthesia
title_full_unstemmed Evaluation and Comparison of Fentanyl versus Nalbuphine for Attenuation of Hemodynamic Response to Laryngoscopy and Endotracheal Intubation in General Anesthesia
title_short Evaluation and Comparison of Fentanyl versus Nalbuphine for Attenuation of Hemodynamic Response to Laryngoscopy and Endotracheal Intubation in General Anesthesia
title_sort evaluation and comparison of fentanyl versus nalbuphine for attenuation of hemodynamic response to laryngoscopy and endotracheal intubation in general anesthesia
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6444961/
https://www.ncbi.nlm.nih.gov/pubmed/31031490
http://dx.doi.org/10.4103/aer.AER_16_19
work_keys_str_mv AT khandayshoiabbashir evaluationandcomparisonoffentanylversusnalbuphineforattenuationofhemodynamicresponsetolaryngoscopyandendotrachealintubationingeneralanesthesia
AT miraabidhussain evaluationandcomparisonoffentanylversusnalbuphineforattenuationofhemodynamicresponsetolaryngoscopyandendotrachealintubationingeneralanesthesia
AT sofikhalidpervaiz evaluationandcomparisonoffentanylversusnalbuphineforattenuationofhemodynamicresponsetolaryngoscopyandendotrachealintubationingeneralanesthesia
AT loneabdulqayoom evaluationandcomparisonoffentanylversusnalbuphineforattenuationofhemodynamicresponsetolaryngoscopyandendotrachealintubationingeneralanesthesia
AT shahareebanoor evaluationandcomparisonoffentanylversusnalbuphineforattenuationofhemodynamicresponsetolaryngoscopyandendotrachealintubationingeneralanesthesia