Cargando…
Applicability of Smartphone for Dynamic Postural Stability Evaluation
The purpose of this study was to determine the accuracy of smartphone's gyroscope for dynamic postural stability among young healthy adults. The research included convenience sample of 85 healthy adults—37 women (mean age 22.1±1.6, body height 167.2±7.0) and 48 men (mean age 22.4±1.7, body heig...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6446100/ https://www.ncbi.nlm.nih.gov/pubmed/31016205 http://dx.doi.org/10.1155/2019/9753898 |
_version_ | 1783408298351919104 |
---|---|
author | Polechoński, Jacek Nawrocka, Agnieszka Wodarski, Piotr Tomik, Rajmund |
author_facet | Polechoński, Jacek Nawrocka, Agnieszka Wodarski, Piotr Tomik, Rajmund |
author_sort | Polechoński, Jacek |
collection | PubMed |
description | The purpose of this study was to determine the accuracy of smartphone's gyroscope for dynamic postural stability among young healthy adults. The research included convenience sample of 85 healthy adults—37 women (mean age 22.1±1.6, body height 167.2±7.0) and 48 men (mean age 22.4±1.7, body height 176.1±13.8). In order to assess the accuracy of stabilometric measurement recorded by mobile phone, the raw data obtained at the same time by Sigma Balance Platform and Smartphone (SP) were correlated. Two thirty-second trials with one-minute interval break were performed (first in the frontal plane and second in the sagittal plane). A total of 170 measurements of postural stability were recorded (85 in frontal and 85 in the sagittal plane). The following parameters were included: the path of the stabilogram (in the case of SP, angular path) and the variation of the swing (standard deviation of the horizontal deflection of the platform). The results have shown strong and significant relationship between body sway variability measured by Sigma platform and smartphone in frontal (r=0.997) and sagittal (r=0.990) plane. For the geometric center of the platform and angular path distances, the correlation coefficient was also statistically significant and high, considering both lateral (r=0.999) and anterior-posterior sway (r=0.981). Our research shows that smartphones with gyroscope have potential for accurate assessment of postural balance, as an alternative for expensive and specialized equipment. |
format | Online Article Text |
id | pubmed-6446100 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-64461002019-04-23 Applicability of Smartphone for Dynamic Postural Stability Evaluation Polechoński, Jacek Nawrocka, Agnieszka Wodarski, Piotr Tomik, Rajmund Biomed Res Int Research Article The purpose of this study was to determine the accuracy of smartphone's gyroscope for dynamic postural stability among young healthy adults. The research included convenience sample of 85 healthy adults—37 women (mean age 22.1±1.6, body height 167.2±7.0) and 48 men (mean age 22.4±1.7, body height 176.1±13.8). In order to assess the accuracy of stabilometric measurement recorded by mobile phone, the raw data obtained at the same time by Sigma Balance Platform and Smartphone (SP) were correlated. Two thirty-second trials with one-minute interval break were performed (first in the frontal plane and second in the sagittal plane). A total of 170 measurements of postural stability were recorded (85 in frontal and 85 in the sagittal plane). The following parameters were included: the path of the stabilogram (in the case of SP, angular path) and the variation of the swing (standard deviation of the horizontal deflection of the platform). The results have shown strong and significant relationship between body sway variability measured by Sigma platform and smartphone in frontal (r=0.997) and sagittal (r=0.990) plane. For the geometric center of the platform and angular path distances, the correlation coefficient was also statistically significant and high, considering both lateral (r=0.999) and anterior-posterior sway (r=0.981). Our research shows that smartphones with gyroscope have potential for accurate assessment of postural balance, as an alternative for expensive and specialized equipment. Hindawi 2019-03-20 /pmc/articles/PMC6446100/ /pubmed/31016205 http://dx.doi.org/10.1155/2019/9753898 Text en Copyright © 2019 Jacek Polechoński et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Polechoński, Jacek Nawrocka, Agnieszka Wodarski, Piotr Tomik, Rajmund Applicability of Smartphone for Dynamic Postural Stability Evaluation |
title | Applicability of Smartphone for Dynamic Postural Stability Evaluation |
title_full | Applicability of Smartphone for Dynamic Postural Stability Evaluation |
title_fullStr | Applicability of Smartphone for Dynamic Postural Stability Evaluation |
title_full_unstemmed | Applicability of Smartphone for Dynamic Postural Stability Evaluation |
title_short | Applicability of Smartphone for Dynamic Postural Stability Evaluation |
title_sort | applicability of smartphone for dynamic postural stability evaluation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6446100/ https://www.ncbi.nlm.nih.gov/pubmed/31016205 http://dx.doi.org/10.1155/2019/9753898 |
work_keys_str_mv | AT polechonskijacek applicabilityofsmartphonefordynamicposturalstabilityevaluation AT nawrockaagnieszka applicabilityofsmartphonefordynamicposturalstabilityevaluation AT wodarskipiotr applicabilityofsmartphonefordynamicposturalstabilityevaluation AT tomikrajmund applicabilityofsmartphonefordynamicposturalstabilityevaluation |