Cargando…
Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water
Since the rose water is used in food, pharmaceutical, and cosmetic products, its microbiological control is necessary. Conventional pasteurization methods cause undesirable changes in taste, smell, medicinal properties and nutritional value with decreasing the amount of essential oil, because of hig...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shaheed Beheshti University of Medical Sciences
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6447883/ https://www.ncbi.nlm.nih.gov/pubmed/31011349 |
_version_ | 1783408590380335104 |
---|---|
author | Rostami, Sajad Behruzian, Mehrsa Hosseinzadeh Samani, Bahram Lorigooini, Zahra Hosseinabadi, Tahereh Zareiforoush, Hemad Behruzian, Ava |
author_facet | Rostami, Sajad Behruzian, Mehrsa Hosseinzadeh Samani, Bahram Lorigooini, Zahra Hosseinabadi, Tahereh Zareiforoush, Hemad Behruzian, Ava |
author_sort | Rostami, Sajad |
collection | PubMed |
description | Since the rose water is used in food, pharmaceutical, and cosmetic products, its microbiological control is necessary. Conventional pasteurization methods cause undesirable changes in taste, smell, medicinal properties and nutritional value with decreasing the amount of essential oil, because of high temperatures. In this study, the effects of the microwave power, temperature, ultrasound power, and ultrasonic exposure were evaluated during rose water pasteurization process on its chemical compositions and E. coli content. In order to determine the microbial inactivation by microwave and ultrasound, E. coli at a concentration of 2 × 10(6) per mL was inoculated to rose aromatic water. The results showed that each variable on the inactivation of E. coli and energy consumption per microbial reduction cycle had a significant effect. The optimum values of microwave power, temperature, ultrasound power, and ultrasound exposure time were obtained 326.24 W, 43.32 °C, 100 W and 4 min, respectively. The chemical composition assessment was done by GC/MS analysis. Phenethyl alcohol is one of the main components of rose water which was completely lost in the conventional pasteurization method, while in pasteurization process by combined method, it showed an acceptable decrease as compared with raw rose water. Furthermore, the proposed method caused minimal changes in the chemical compositions of the rose water as compared to the conventional heating methods. |
format | Online Article Text |
id | pubmed-6447883 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Shaheed Beheshti University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-64478832019-04-22 Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water Rostami, Sajad Behruzian, Mehrsa Hosseinzadeh Samani, Bahram Lorigooini, Zahra Hosseinabadi, Tahereh Zareiforoush, Hemad Behruzian, Ava Iran J Pharm Res Original Article Since the rose water is used in food, pharmaceutical, and cosmetic products, its microbiological control is necessary. Conventional pasteurization methods cause undesirable changes in taste, smell, medicinal properties and nutritional value with decreasing the amount of essential oil, because of high temperatures. In this study, the effects of the microwave power, temperature, ultrasound power, and ultrasonic exposure were evaluated during rose water pasteurization process on its chemical compositions and E. coli content. In order to determine the microbial inactivation by microwave and ultrasound, E. coli at a concentration of 2 × 10(6) per mL was inoculated to rose aromatic water. The results showed that each variable on the inactivation of E. coli and energy consumption per microbial reduction cycle had a significant effect. The optimum values of microwave power, temperature, ultrasound power, and ultrasound exposure time were obtained 326.24 W, 43.32 °C, 100 W and 4 min, respectively. The chemical composition assessment was done by GC/MS analysis. Phenethyl alcohol is one of the main components of rose water which was completely lost in the conventional pasteurization method, while in pasteurization process by combined method, it showed an acceptable decrease as compared with raw rose water. Furthermore, the proposed method caused minimal changes in the chemical compositions of the rose water as compared to the conventional heating methods. Shaheed Beheshti University of Medical Sciences 2018 /pmc/articles/PMC6447883/ /pubmed/31011349 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Rostami, Sajad Behruzian, Mehrsa Hosseinzadeh Samani, Bahram Lorigooini, Zahra Hosseinabadi, Tahereh Zareiforoush, Hemad Behruzian, Ava Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water |
title | Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water |
title_full | Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water |
title_fullStr | Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water |
title_full_unstemmed | Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water |
title_short | Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water |
title_sort | study of combined ultrasound-microwave effect on chemical compositions and e. coli count of rose aromatic water |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6447883/ https://www.ncbi.nlm.nih.gov/pubmed/31011349 |
work_keys_str_mv | AT rostamisajad studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater AT behruzianmehrsa studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater AT hosseinzadehsamanibahram studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater AT lorigooinizahra studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater AT hosseinabaditahereh studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater AT zareiforoushhemad studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater AT behruzianava studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater |