Cargando…

Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water

Since the rose water is used in food, pharmaceutical, and cosmetic products, its microbiological control is necessary. Conventional pasteurization methods cause undesirable changes in taste, smell, medicinal properties and nutritional value with decreasing the amount of essential oil, because of hig...

Descripción completa

Detalles Bibliográficos
Autores principales: Rostami, Sajad, Behruzian, Mehrsa, Hosseinzadeh Samani, Bahram, Lorigooini, Zahra, Hosseinabadi, Tahereh, Zareiforoush, Hemad, Behruzian, Ava
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shaheed Beheshti University of Medical Sciences 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6447883/
https://www.ncbi.nlm.nih.gov/pubmed/31011349
_version_ 1783408590380335104
author Rostami, Sajad
Behruzian, Mehrsa
Hosseinzadeh Samani, Bahram
Lorigooini, Zahra
Hosseinabadi, Tahereh
Zareiforoush, Hemad
Behruzian, Ava
author_facet Rostami, Sajad
Behruzian, Mehrsa
Hosseinzadeh Samani, Bahram
Lorigooini, Zahra
Hosseinabadi, Tahereh
Zareiforoush, Hemad
Behruzian, Ava
author_sort Rostami, Sajad
collection PubMed
description Since the rose water is used in food, pharmaceutical, and cosmetic products, its microbiological control is necessary. Conventional pasteurization methods cause undesirable changes in taste, smell, medicinal properties and nutritional value with decreasing the amount of essential oil, because of high temperatures. In this study, the effects of the microwave power, temperature, ultrasound power, and ultrasonic exposure were evaluated during rose water pasteurization process on its chemical compositions and E. coli content. In order to determine the microbial inactivation by microwave and ultrasound, E. coli at a concentration of 2 × 10(6) per mL was inoculated to rose aromatic water. The results showed that each variable on the inactivation of E. coli and energy consumption per microbial reduction cycle had a significant effect. The optimum values of microwave power, temperature, ultrasound power, and ultrasound exposure time were obtained 326.24 W, 43.32 °C, 100 W and 4 min, respectively. The chemical composition assessment was done by GC/MS analysis. Phenethyl alcohol is one of the main components of rose water which was completely lost in the conventional pasteurization method, while in pasteurization process by combined method, it showed an acceptable decrease as compared with raw rose water. Furthermore, the proposed method caused minimal changes in the chemical compositions of the rose water as compared to the conventional heating methods.
format Online
Article
Text
id pubmed-6447883
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Shaheed Beheshti University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-64478832019-04-22 Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water Rostami, Sajad Behruzian, Mehrsa Hosseinzadeh Samani, Bahram Lorigooini, Zahra Hosseinabadi, Tahereh Zareiforoush, Hemad Behruzian, Ava Iran J Pharm Res Original Article Since the rose water is used in food, pharmaceutical, and cosmetic products, its microbiological control is necessary. Conventional pasteurization methods cause undesirable changes in taste, smell, medicinal properties and nutritional value with decreasing the amount of essential oil, because of high temperatures. In this study, the effects of the microwave power, temperature, ultrasound power, and ultrasonic exposure were evaluated during rose water pasteurization process on its chemical compositions and E. coli content. In order to determine the microbial inactivation by microwave and ultrasound, E. coli at a concentration of 2 × 10(6) per mL was inoculated to rose aromatic water. The results showed that each variable on the inactivation of E. coli and energy consumption per microbial reduction cycle had a significant effect. The optimum values of microwave power, temperature, ultrasound power, and ultrasound exposure time were obtained 326.24 W, 43.32 °C, 100 W and 4 min, respectively. The chemical composition assessment was done by GC/MS analysis. Phenethyl alcohol is one of the main components of rose water which was completely lost in the conventional pasteurization method, while in pasteurization process by combined method, it showed an acceptable decrease as compared with raw rose water. Furthermore, the proposed method caused minimal changes in the chemical compositions of the rose water as compared to the conventional heating methods. Shaheed Beheshti University of Medical Sciences 2018 /pmc/articles/PMC6447883/ /pubmed/31011349 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Rostami, Sajad
Behruzian, Mehrsa
Hosseinzadeh Samani, Bahram
Lorigooini, Zahra
Hosseinabadi, Tahereh
Zareiforoush, Hemad
Behruzian, Ava
Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water
title Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water
title_full Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water
title_fullStr Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water
title_full_unstemmed Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water
title_short Study of Combined Ultrasound-microwave Effect on Chemical Compositions and E. coli Count of Rose Aromatic Water
title_sort study of combined ultrasound-microwave effect on chemical compositions and e. coli count of rose aromatic water
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6447883/
https://www.ncbi.nlm.nih.gov/pubmed/31011349
work_keys_str_mv AT rostamisajad studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater
AT behruzianmehrsa studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater
AT hosseinzadehsamanibahram studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater
AT lorigooinizahra studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater
AT hosseinabaditahereh studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater
AT zareiforoushhemad studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater
AT behruzianava studyofcombinedultrasoundmicrowaveeffectonchemicalcompositionsandecolicountofrosearomaticwater