Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study
PURPOSE: Beam matching occurs on all linacs to some degree and when two are more are matched to each other, patients are able to be transferred between machines. Quality assurance of plans can also be performed “distributively” on any of the matched linacs. The degree to which machines are matched a...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6448346/ https://www.ncbi.nlm.nih.gov/pubmed/30883010 http://dx.doi.org/10.1002/acm2.12567 |
_version_ | 1783408685086670848 |
---|---|
author | Rijken, James Schachenmayr, Hilmar Crowe, Scott Kairn, Tanya Trapp, Jamie |
author_facet | Rijken, James Schachenmayr, Hilmar Crowe, Scott Kairn, Tanya Trapp, Jamie |
author_sort | Rijken, James |
collection | PubMed |
description | PURPOSE: Beam matching occurs on all linacs to some degree and when two are more are matched to each other, patients are able to be transferred between machines. Quality assurance of plans can also be performed “distributively” on any of the matched linacs. The degree to which machines are matched and how this translates to like delivery of plans has been the focus of a number of studies. This concept has not yet been explored for stereotactic techniques which require a higher degree of accuracy. This study proposes beam matching criteria which allows for the distributive delivery and quality assurance of stereotactic body radiotherapy (SBRT) plans. METHOD: Two clinically relevant and complex volumetric modulated arc therapy (VMAT) SBRT spine and lung plans were chosen as benchmarking cases. These were delivered on nine previously beam matched linacs with quality assurance performed through ArcCheck and film exposure in the sagittal plane. Measured doses were compared to their treatment planning system predictions through gamma analysis at a range of criteria. RESULTS: Despite differences in beam match parameters and variations in small fields, all nine linacs produced accurate deliveries with a tight deviation in the population sample. Pass rates were well above suggested tolerances at the recommended gamma criterion. Film was able to detect dose errors to a greater degree than ArcCheck. CONCLUSION: Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linacs is certainly feasible provided the linacs are matched to a strict protocol like that suggested in this study and regular quality assurance is performed on the matched fleet. Distributive quality assurance and delivery of SBRT provides the possibility of efficiency gains for physicists as well as treatment staff. |
format | Online Article Text |
id | pubmed-6448346 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-64483462019-04-15 Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study Rijken, James Schachenmayr, Hilmar Crowe, Scott Kairn, Tanya Trapp, Jamie J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: Beam matching occurs on all linacs to some degree and when two are more are matched to each other, patients are able to be transferred between machines. Quality assurance of plans can also be performed “distributively” on any of the matched linacs. The degree to which machines are matched and how this translates to like delivery of plans has been the focus of a number of studies. This concept has not yet been explored for stereotactic techniques which require a higher degree of accuracy. This study proposes beam matching criteria which allows for the distributive delivery and quality assurance of stereotactic body radiotherapy (SBRT) plans. METHOD: Two clinically relevant and complex volumetric modulated arc therapy (VMAT) SBRT spine and lung plans were chosen as benchmarking cases. These were delivered on nine previously beam matched linacs with quality assurance performed through ArcCheck and film exposure in the sagittal plane. Measured doses were compared to their treatment planning system predictions through gamma analysis at a range of criteria. RESULTS: Despite differences in beam match parameters and variations in small fields, all nine linacs produced accurate deliveries with a tight deviation in the population sample. Pass rates were well above suggested tolerances at the recommended gamma criterion. Film was able to detect dose errors to a greater degree than ArcCheck. CONCLUSION: Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linacs is certainly feasible provided the linacs are matched to a strict protocol like that suggested in this study and regular quality assurance is performed on the matched fleet. Distributive quality assurance and delivery of SBRT provides the possibility of efficiency gains for physicists as well as treatment staff. John Wiley and Sons Inc. 2019-03-18 /pmc/articles/PMC6448346/ /pubmed/30883010 http://dx.doi.org/10.1002/acm2.12567 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Rijken, James Schachenmayr, Hilmar Crowe, Scott Kairn, Tanya Trapp, Jamie Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study |
title | Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study |
title_full | Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study |
title_fullStr | Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study |
title_full_unstemmed | Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study |
title_short | Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study |
title_sort | distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: a feasibility study |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6448346/ https://www.ncbi.nlm.nih.gov/pubmed/30883010 http://dx.doi.org/10.1002/acm2.12567 |
work_keys_str_mv | AT rijkenjames distributivequalityassuranceanddeliveryofstereotacticablativeradiotherapytreatmentsamongstbeammatchedlinearacceleratorsafeasibilitystudy AT schachenmayrhilmar distributivequalityassuranceanddeliveryofstereotacticablativeradiotherapytreatmentsamongstbeammatchedlinearacceleratorsafeasibilitystudy AT crowescott distributivequalityassuranceanddeliveryofstereotacticablativeradiotherapytreatmentsamongstbeammatchedlinearacceleratorsafeasibilitystudy AT kairntanya distributivequalityassuranceanddeliveryofstereotacticablativeradiotherapytreatmentsamongstbeammatchedlinearacceleratorsafeasibilitystudy AT trappjamie distributivequalityassuranceanddeliveryofstereotacticablativeradiotherapytreatmentsamongstbeammatchedlinearacceleratorsafeasibilitystudy |