Cargando…

Comparing the Relative Strengths of EEG and Low-Cost Physiological Devices in Modeling Attention Allocation in Semiautonomous Vehicles

As semiautonomous driving systems are becoming prevalent in late model vehicles, it is important to understand how such systems affect driver attention. This study investigated whether measures from low-cost devices monitoring peripheral physiological state were comparable to standard EEG in predict...

Descripción completa

Detalles Bibliográficos
Autores principales: Cisler, Dean, Greenwood, Pamela M., Roberts, Daniel M., McKendrick, Ryan, Baldwin, Carryl L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6449700/
https://www.ncbi.nlm.nih.gov/pubmed/30983982
http://dx.doi.org/10.3389/fnhum.2019.00109
_version_ 1783408904764391424
author Cisler, Dean
Greenwood, Pamela M.
Roberts, Daniel M.
McKendrick, Ryan
Baldwin, Carryl L.
author_facet Cisler, Dean
Greenwood, Pamela M.
Roberts, Daniel M.
McKendrick, Ryan
Baldwin, Carryl L.
author_sort Cisler, Dean
collection PubMed
description As semiautonomous driving systems are becoming prevalent in late model vehicles, it is important to understand how such systems affect driver attention. This study investigated whether measures from low-cost devices monitoring peripheral physiological state were comparable to standard EEG in predicting lapses in attention to system failures. Twenty-five participants were equipped with a low-fidelity eye-tracker and heart rate monitor and with a high-fidelity NuAmps 32-channel quick-gel EEG system and asked to detect the presence of potential system failure while engaged in a fully autonomous lane changing driving task. To encourage participant attention to the road and to assess engagement in the lane changing task, participants were required to: (a) answer questions about that task; and (b) keep a running count of the type and number of billboards presented throughout the driving task. Linear mixed effects analyses were conducted to model the latency of responses reaction time (RT) to automation signals using the physiological metrics and time period. Alpha-band activity at the midline parietal region in conjunction with heart rate variability (HRV) was important in modeling RT over time. Results suggest that current low-fidelity technologies are not sensitive enough by themselves to reliably model RT to critical signals. However, that HRV interacted with EEG to significantly model RT points to the importance of further developing heart rate metrics for use in environments where it is not practical to use EEG.
format Online
Article
Text
id pubmed-6449700
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-64497002019-04-12 Comparing the Relative Strengths of EEG and Low-Cost Physiological Devices in Modeling Attention Allocation in Semiautonomous Vehicles Cisler, Dean Greenwood, Pamela M. Roberts, Daniel M. McKendrick, Ryan Baldwin, Carryl L. Front Hum Neurosci Neuroscience As semiautonomous driving systems are becoming prevalent in late model vehicles, it is important to understand how such systems affect driver attention. This study investigated whether measures from low-cost devices monitoring peripheral physiological state were comparable to standard EEG in predicting lapses in attention to system failures. Twenty-five participants were equipped with a low-fidelity eye-tracker and heart rate monitor and with a high-fidelity NuAmps 32-channel quick-gel EEG system and asked to detect the presence of potential system failure while engaged in a fully autonomous lane changing driving task. To encourage participant attention to the road and to assess engagement in the lane changing task, participants were required to: (a) answer questions about that task; and (b) keep a running count of the type and number of billboards presented throughout the driving task. Linear mixed effects analyses were conducted to model the latency of responses reaction time (RT) to automation signals using the physiological metrics and time period. Alpha-band activity at the midline parietal region in conjunction with heart rate variability (HRV) was important in modeling RT over time. Results suggest that current low-fidelity technologies are not sensitive enough by themselves to reliably model RT to critical signals. However, that HRV interacted with EEG to significantly model RT points to the importance of further developing heart rate metrics for use in environments where it is not practical to use EEG. Frontiers Media S.A. 2019-03-29 /pmc/articles/PMC6449700/ /pubmed/30983982 http://dx.doi.org/10.3389/fnhum.2019.00109 Text en Copyright © 2019 Cisler, Greenwood, Roberts, McKendrick and Baldwin. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Cisler, Dean
Greenwood, Pamela M.
Roberts, Daniel M.
McKendrick, Ryan
Baldwin, Carryl L.
Comparing the Relative Strengths of EEG and Low-Cost Physiological Devices in Modeling Attention Allocation in Semiautonomous Vehicles
title Comparing the Relative Strengths of EEG and Low-Cost Physiological Devices in Modeling Attention Allocation in Semiautonomous Vehicles
title_full Comparing the Relative Strengths of EEG and Low-Cost Physiological Devices in Modeling Attention Allocation in Semiautonomous Vehicles
title_fullStr Comparing the Relative Strengths of EEG and Low-Cost Physiological Devices in Modeling Attention Allocation in Semiautonomous Vehicles
title_full_unstemmed Comparing the Relative Strengths of EEG and Low-Cost Physiological Devices in Modeling Attention Allocation in Semiautonomous Vehicles
title_short Comparing the Relative Strengths of EEG and Low-Cost Physiological Devices in Modeling Attention Allocation in Semiautonomous Vehicles
title_sort comparing the relative strengths of eeg and low-cost physiological devices in modeling attention allocation in semiautonomous vehicles
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6449700/
https://www.ncbi.nlm.nih.gov/pubmed/30983982
http://dx.doi.org/10.3389/fnhum.2019.00109
work_keys_str_mv AT cislerdean comparingtherelativestrengthsofeegandlowcostphysiologicaldevicesinmodelingattentionallocationinsemiautonomousvehicles
AT greenwoodpamelam comparingtherelativestrengthsofeegandlowcostphysiologicaldevicesinmodelingattentionallocationinsemiautonomousvehicles
AT robertsdanielm comparingtherelativestrengthsofeegandlowcostphysiologicaldevicesinmodelingattentionallocationinsemiautonomousvehicles
AT mckendrickryan comparingtherelativestrengthsofeegandlowcostphysiologicaldevicesinmodelingattentionallocationinsemiautonomousvehicles
AT baldwincarryll comparingtherelativestrengthsofeegandlowcostphysiologicaldevicesinmodelingattentionallocationinsemiautonomousvehicles