Cargando…

Trends in implantable cardioverter defibrillator and cardiac resynchronisation therapy lead parameters for patients with arrhythmogenic and dilated cardiomyopathies

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead parameters may deteriorate due to right ventricular (RV) disease such as arrhythmogenic right ventricular cardiomyopathy (ARVC), with implications for safe delivery of therapies. We compared ICD and CRT-D (cardiac resynchronisation therap...

Descripción completa

Detalles Bibliográficos
Autores principales: Lane, Jem D., Whittaker-Axon, Sarah, Schilling, Richard J., Lowe, Martin D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6450828/
https://www.ncbi.nlm.nih.gov/pubmed/30145313
http://dx.doi.org/10.1016/j.ipej.2018.08.004
_version_ 1783409073817911296
author Lane, Jem D.
Whittaker-Axon, Sarah
Schilling, Richard J.
Lowe, Martin D.
author_facet Lane, Jem D.
Whittaker-Axon, Sarah
Schilling, Richard J.
Lowe, Martin D.
author_sort Lane, Jem D.
collection PubMed
description BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead parameters may deteriorate due to right ventricular (RV) disease such as arrhythmogenic right ventricular cardiomyopathy (ARVC), with implications for safe delivery of therapies. We compared ICD and CRT-D (cardiac resynchronisation therapy-defibrillator) lead parameters in patients with ARVC and dilated cardiomyopathy (DCM). METHODS: RV lead sensing (R wave amplitude) and pacing (threshold and amplitude-pulse width product (APWP)), left ventricular (LV) pacing (APWP), and imaging parameter trends were assessed in 18 patients with ARVC and 18 with DCM. RESULTS: R wave amplitude did not change significantly over time in either group (over 5 years, ARVC -0.4 mV, 95% CI -3.8–3.0 mV; DCM -1.8 mV, 95% CI -5.0–1.3 mV). Within ARVC group, divergent trends were seen according to lead position. DCM patients experienced an increase in RV lead threshold (+1.1 V over 5 years, 95% CI + 0.5 to +1.7 V) and RV APWP (+0.48 Vms over 5 years, 95% CI + 0.24 to +0.71 Vms); ARVC patients had no change. ARVC patients had a higher LVEF at baseline than DCM patients (52 vs 20%, p < 0.001), though LVEF decreased over time for the former, while increasing for the latter. TAPSE did not change over time for ARVC patients. CONCLUSIONS: Lead parameters in ARVC patients were stable over medium-term follow up. In DCM patients, RV lead threshold and RV and LV APWP increased over time. These differential responses for DCM and ARVC were not explained by imaging indices, and may reflect distinct patterns of disease progression.
format Online
Article
Text
id pubmed-6450828
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-64508282019-04-16 Trends in implantable cardioverter defibrillator and cardiac resynchronisation therapy lead parameters for patients with arrhythmogenic and dilated cardiomyopathies Lane, Jem D. Whittaker-Axon, Sarah Schilling, Richard J. Lowe, Martin D. Indian Pacing Electrophysiol J Original Article BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead parameters may deteriorate due to right ventricular (RV) disease such as arrhythmogenic right ventricular cardiomyopathy (ARVC), with implications for safe delivery of therapies. We compared ICD and CRT-D (cardiac resynchronisation therapy-defibrillator) lead parameters in patients with ARVC and dilated cardiomyopathy (DCM). METHODS: RV lead sensing (R wave amplitude) and pacing (threshold and amplitude-pulse width product (APWP)), left ventricular (LV) pacing (APWP), and imaging parameter trends were assessed in 18 patients with ARVC and 18 with DCM. RESULTS: R wave amplitude did not change significantly over time in either group (over 5 years, ARVC -0.4 mV, 95% CI -3.8–3.0 mV; DCM -1.8 mV, 95% CI -5.0–1.3 mV). Within ARVC group, divergent trends were seen according to lead position. DCM patients experienced an increase in RV lead threshold (+1.1 V over 5 years, 95% CI + 0.5 to +1.7 V) and RV APWP (+0.48 Vms over 5 years, 95% CI + 0.24 to +0.71 Vms); ARVC patients had no change. ARVC patients had a higher LVEF at baseline than DCM patients (52 vs 20%, p < 0.001), though LVEF decreased over time for the former, while increasing for the latter. TAPSE did not change over time for ARVC patients. CONCLUSIONS: Lead parameters in ARVC patients were stable over medium-term follow up. In DCM patients, RV lead threshold and RV and LV APWP increased over time. These differential responses for DCM and ARVC were not explained by imaging indices, and may reflect distinct patterns of disease progression. Elsevier 2018-08-23 /pmc/articles/PMC6450828/ /pubmed/30145313 http://dx.doi.org/10.1016/j.ipej.2018.08.004 Text en © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Lane, Jem D.
Whittaker-Axon, Sarah
Schilling, Richard J.
Lowe, Martin D.
Trends in implantable cardioverter defibrillator and cardiac resynchronisation therapy lead parameters for patients with arrhythmogenic and dilated cardiomyopathies
title Trends in implantable cardioverter defibrillator and cardiac resynchronisation therapy lead parameters for patients with arrhythmogenic and dilated cardiomyopathies
title_full Trends in implantable cardioverter defibrillator and cardiac resynchronisation therapy lead parameters for patients with arrhythmogenic and dilated cardiomyopathies
title_fullStr Trends in implantable cardioverter defibrillator and cardiac resynchronisation therapy lead parameters for patients with arrhythmogenic and dilated cardiomyopathies
title_full_unstemmed Trends in implantable cardioverter defibrillator and cardiac resynchronisation therapy lead parameters for patients with arrhythmogenic and dilated cardiomyopathies
title_short Trends in implantable cardioverter defibrillator and cardiac resynchronisation therapy lead parameters for patients with arrhythmogenic and dilated cardiomyopathies
title_sort trends in implantable cardioverter defibrillator and cardiac resynchronisation therapy lead parameters for patients with arrhythmogenic and dilated cardiomyopathies
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6450828/
https://www.ncbi.nlm.nih.gov/pubmed/30145313
http://dx.doi.org/10.1016/j.ipej.2018.08.004
work_keys_str_mv AT lanejemd trendsinimplantablecardioverterdefibrillatorandcardiacresynchronisationtherapyleadparametersforpatientswitharrhythmogenicanddilatedcardiomyopathies
AT whittakeraxonsarah trendsinimplantablecardioverterdefibrillatorandcardiacresynchronisationtherapyleadparametersforpatientswitharrhythmogenicanddilatedcardiomyopathies
AT schillingrichardj trendsinimplantablecardioverterdefibrillatorandcardiacresynchronisationtherapyleadparametersforpatientswitharrhythmogenicanddilatedcardiomyopathies
AT lowemartind trendsinimplantablecardioverterdefibrillatorandcardiacresynchronisationtherapyleadparametersforpatientswitharrhythmogenicanddilatedcardiomyopathies