Cargando…

Auditory temporal resolution in adaptive tasks: Gap detection investigation

OBJECTIVES: To study auditory temporal resolution skills using adaptive auditory tasks designed with a computer-based experimental program, and to provide normative values for gap detection thresholds (GDTs) of young listeners in 3 listening conditions. METHODS: The GDTs were established under 3 sti...

Descripción completa

Detalles Bibliográficos
Autores principales: Alhaidary, Abdulsalam A., Tanniru, Kishore, Aljadaan, Adel F., Alabdulkarim, Lamya M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Saudi Medical Journal 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6452600/
https://www.ncbi.nlm.nih.gov/pubmed/30617381
http://dx.doi.org/10.15537/smj.2019.1.23814
_version_ 1783409323321327616
author Alhaidary, Abdulsalam A.
Tanniru, Kishore
Aljadaan, Adel F.
Alabdulkarim, Lamya M.
author_facet Alhaidary, Abdulsalam A.
Tanniru, Kishore
Aljadaan, Adel F.
Alabdulkarim, Lamya M.
author_sort Alhaidary, Abdulsalam A.
collection PubMed
description OBJECTIVES: To study auditory temporal resolution skills using adaptive auditory tasks designed with a computer-based experimental program, and to provide normative values for gap detection thresholds (GDTs) of young listeners in 3 listening conditions. METHODS: The GDTs were established under 3 stimulus conditions: 1) broadband noise (BBN), 2) narrowband noise within-channel (NBN WC) using similar leading and trailing markers centered at 1.0 KHz, and 3) narrowband noise across-channel (NBN AC) with the leading marker centered at 2.0 KHz and the trailing marker centered at 1.0 KHz. In within-subjects design, the GDTs were obtained from 27 normal hearing young Saudi adults at Speech and Hearing Laboratories, Department of Rehabilitation Health Sciences, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia between April 2017 and April 2018. RESULTS: The mean GDTs for the BBN condition was 3.19 millisecsond (msec), NBN WC was 14.53 msec, and NBN AC was 29.71 msec. Our findings for the GDTs measured in the 3 conditions were consistent with those of earlier investigations that used different instrumentations. Also, no correlations among the GDTs of the 3 stimulus conditions were found. CONCLUSION: The present study showed that experimental program is a reliable tool with clinical potential to estimate GDTs across different conditions. Also, the findings of no correlations in the GDTs across stimulus conditions suggest that different processes were involved in the perception of the temporal gap for different stimulus conditions.
format Online
Article
Text
id pubmed-6452600
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Saudi Medical Journal
record_format MEDLINE/PubMed
spelling pubmed-64526002019-04-29 Auditory temporal resolution in adaptive tasks: Gap detection investigation Alhaidary, Abdulsalam A. Tanniru, Kishore Aljadaan, Adel F. Alabdulkarim, Lamya M. Saudi Med J Original Article OBJECTIVES: To study auditory temporal resolution skills using adaptive auditory tasks designed with a computer-based experimental program, and to provide normative values for gap detection thresholds (GDTs) of young listeners in 3 listening conditions. METHODS: The GDTs were established under 3 stimulus conditions: 1) broadband noise (BBN), 2) narrowband noise within-channel (NBN WC) using similar leading and trailing markers centered at 1.0 KHz, and 3) narrowband noise across-channel (NBN AC) with the leading marker centered at 2.0 KHz and the trailing marker centered at 1.0 KHz. In within-subjects design, the GDTs were obtained from 27 normal hearing young Saudi adults at Speech and Hearing Laboratories, Department of Rehabilitation Health Sciences, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia between April 2017 and April 2018. RESULTS: The mean GDTs for the BBN condition was 3.19 millisecsond (msec), NBN WC was 14.53 msec, and NBN AC was 29.71 msec. Our findings for the GDTs measured in the 3 conditions were consistent with those of earlier investigations that used different instrumentations. Also, no correlations among the GDTs of the 3 stimulus conditions were found. CONCLUSION: The present study showed that experimental program is a reliable tool with clinical potential to estimate GDTs across different conditions. Also, the findings of no correlations in the GDTs across stimulus conditions suggest that different processes were involved in the perception of the temporal gap for different stimulus conditions. Saudi Medical Journal 2019-01 /pmc/articles/PMC6452600/ /pubmed/30617381 http://dx.doi.org/10.15537/smj.2019.1.23814 Text en Copyright: © Saudi Medical Journal https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Alhaidary, Abdulsalam A.
Tanniru, Kishore
Aljadaan, Adel F.
Alabdulkarim, Lamya M.
Auditory temporal resolution in adaptive tasks: Gap detection investigation
title Auditory temporal resolution in adaptive tasks: Gap detection investigation
title_full Auditory temporal resolution in adaptive tasks: Gap detection investigation
title_fullStr Auditory temporal resolution in adaptive tasks: Gap detection investigation
title_full_unstemmed Auditory temporal resolution in adaptive tasks: Gap detection investigation
title_short Auditory temporal resolution in adaptive tasks: Gap detection investigation
title_sort auditory temporal resolution in adaptive tasks: gap detection investigation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6452600/
https://www.ncbi.nlm.nih.gov/pubmed/30617381
http://dx.doi.org/10.15537/smj.2019.1.23814
work_keys_str_mv AT alhaidaryabdulsalama auditorytemporalresolutioninadaptivetasksgapdetectioninvestigation
AT tannirukishore auditorytemporalresolutioninadaptivetasksgapdetectioninvestigation
AT aljadaanadelf auditorytemporalresolutioninadaptivetasksgapdetectioninvestigation
AT alabdulkarimlamyam auditorytemporalresolutioninadaptivetasksgapdetectioninvestigation