Cargando…

Direct measurement of plantarflexion resistive moments and angular positions of an articulated ankle–foot orthosis while walking in individuals post stroke: A preliminary study

The plantarflexion resistive moments of an articulated ankle–foot orthosis play an important role in improving gait in individuals post stroke. However, the evidence regarding their magnitude required from the articulated ankle–foot orthosis to improve walking is still limited. Therefore, the primar...

Descripción completa

Detalles Bibliográficos
Autores principales: Kobayashi, Toshiki, Orendurff, Michael S, Singer, Madeline L, Daly, Wayne K, Lincoln, Lucas S, Gao, Fan, Foreman, K Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6453032/
https://www.ncbi.nlm.nih.gov/pubmed/31186901
http://dx.doi.org/10.1177/2055668316639445
_version_ 1783409366455549952
author Kobayashi, Toshiki
Orendurff, Michael S
Singer, Madeline L
Daly, Wayne K
Lincoln, Lucas S
Gao, Fan
Foreman, K Bo
author_facet Kobayashi, Toshiki
Orendurff, Michael S
Singer, Madeline L
Daly, Wayne K
Lincoln, Lucas S
Gao, Fan
Foreman, K Bo
author_sort Kobayashi, Toshiki
collection PubMed
description The plantarflexion resistive moments of an articulated ankle–foot orthosis play an important role in improving gait in individuals post stroke. However, the evidence regarding their magnitude required from the articulated ankle–foot orthosis to improve walking is still limited. Therefore, the primary aim of this study was to directly measure the plantarflexion resistive moments and the joint angular positions while walking using a prototype instrumented articulated ankle–foot orthosis in five individuals post stroke. The secondary aim was to investigate their moment–angle relationship by changing its preset plantarflexion stiffness. Each subject was fitted with the instrumented articulated ankle–foot orthosis and walked on a treadmill under four different preset plantarflexion stiffness conditions (0.35 N·m/°, 0.51 N·m/°, 0.87 N·m/°, and 1.27 N·m/°). For each subject, the plantarflexion resistive moments and the joint angular positions of five continuous gait cycles were extracted and averaged for each condition. Data were plotted and presented as case series. Both plantarflexion resistive moments and joint angular positions of the ankle–foot orthosis changed according to the preset plantarflexion stiffness in all subjects. Using the instrumented articulated ankle–foot orthosis could potentially advance the understanding of the biomechanics of an ankle–foot orthosis, as well as contribute to more evidence-based orthotic care of patients.
format Online
Article
Text
id pubmed-6453032
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-64530322019-06-11 Direct measurement of plantarflexion resistive moments and angular positions of an articulated ankle–foot orthosis while walking in individuals post stroke: A preliminary study Kobayashi, Toshiki Orendurff, Michael S Singer, Madeline L Daly, Wayne K Lincoln, Lucas S Gao, Fan Foreman, K Bo J Rehabil Assist Technol Eng Technical Notes The plantarflexion resistive moments of an articulated ankle–foot orthosis play an important role in improving gait in individuals post stroke. However, the evidence regarding their magnitude required from the articulated ankle–foot orthosis to improve walking is still limited. Therefore, the primary aim of this study was to directly measure the plantarflexion resistive moments and the joint angular positions while walking using a prototype instrumented articulated ankle–foot orthosis in five individuals post stroke. The secondary aim was to investigate their moment–angle relationship by changing its preset plantarflexion stiffness. Each subject was fitted with the instrumented articulated ankle–foot orthosis and walked on a treadmill under four different preset plantarflexion stiffness conditions (0.35 N·m/°, 0.51 N·m/°, 0.87 N·m/°, and 1.27 N·m/°). For each subject, the plantarflexion resistive moments and the joint angular positions of five continuous gait cycles were extracted and averaged for each condition. Data were plotted and presented as case series. Both plantarflexion resistive moments and joint angular positions of the ankle–foot orthosis changed according to the preset plantarflexion stiffness in all subjects. Using the instrumented articulated ankle–foot orthosis could potentially advance the understanding of the biomechanics of an ankle–foot orthosis, as well as contribute to more evidence-based orthotic care of patients. SAGE Publications 2016-03-31 /pmc/articles/PMC6453032/ /pubmed/31186901 http://dx.doi.org/10.1177/2055668316639445 Text en © The Author(s) 2016 http://creativecommons.org/licenses/by-nc/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page(https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Technical Notes
Kobayashi, Toshiki
Orendurff, Michael S
Singer, Madeline L
Daly, Wayne K
Lincoln, Lucas S
Gao, Fan
Foreman, K Bo
Direct measurement of plantarflexion resistive moments and angular positions of an articulated ankle–foot orthosis while walking in individuals post stroke: A preliminary study
title Direct measurement of plantarflexion resistive moments and angular positions of an articulated ankle–foot orthosis while walking in individuals post stroke: A preliminary study
title_full Direct measurement of plantarflexion resistive moments and angular positions of an articulated ankle–foot orthosis while walking in individuals post stroke: A preliminary study
title_fullStr Direct measurement of plantarflexion resistive moments and angular positions of an articulated ankle–foot orthosis while walking in individuals post stroke: A preliminary study
title_full_unstemmed Direct measurement of plantarflexion resistive moments and angular positions of an articulated ankle–foot orthosis while walking in individuals post stroke: A preliminary study
title_short Direct measurement of plantarflexion resistive moments and angular positions of an articulated ankle–foot orthosis while walking in individuals post stroke: A preliminary study
title_sort direct measurement of plantarflexion resistive moments and angular positions of an articulated ankle–foot orthosis while walking in individuals post stroke: a preliminary study
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6453032/
https://www.ncbi.nlm.nih.gov/pubmed/31186901
http://dx.doi.org/10.1177/2055668316639445
work_keys_str_mv AT kobayashitoshiki directmeasurementofplantarflexionresistivemomentsandangularpositionsofanarticulatedanklefootorthosiswhilewalkinginindividualspoststrokeapreliminarystudy
AT orendurffmichaels directmeasurementofplantarflexionresistivemomentsandangularpositionsofanarticulatedanklefootorthosiswhilewalkinginindividualspoststrokeapreliminarystudy
AT singermadelinel directmeasurementofplantarflexionresistivemomentsandangularpositionsofanarticulatedanklefootorthosiswhilewalkinginindividualspoststrokeapreliminarystudy
AT dalywaynek directmeasurementofplantarflexionresistivemomentsandangularpositionsofanarticulatedanklefootorthosiswhilewalkinginindividualspoststrokeapreliminarystudy
AT lincolnlucass directmeasurementofplantarflexionresistivemomentsandangularpositionsofanarticulatedanklefootorthosiswhilewalkinginindividualspoststrokeapreliminarystudy
AT gaofan directmeasurementofplantarflexionresistivemomentsandangularpositionsofanarticulatedanklefootorthosiswhilewalkinginindividualspoststrokeapreliminarystudy
AT foremankbo directmeasurementofplantarflexionresistivemomentsandangularpositionsofanarticulatedanklefootorthosiswhilewalkinginindividualspoststrokeapreliminarystudy