Cargando…

The use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy

PURPOSE: The aim of this retrospective study was to investigate the use of a radiopaque tissue fiducial marker (TFM) in the treatment of prostate cancer patients who undergo post-prostatectomy radiotherapy (PPRT). TFM safety, its role and benefit in quantifying the set-up uncertainties in patients u...

Descripción completa

Detalles Bibliográficos
Autores principales: Chao, Michael, Ho, Huong, Joon, Daryl Lim, Chan, Yee, Spencer, Sandra, Ng, Michael, Wasiak, Jason, Lawrentschuk, Nathan, McMillan, Kevin, Sengupta, Shomik, Tan, Alwin, Koufogiannis, George, Cokelek, Margaret, Foroudi, Farshad, Khong, Tristan-Scott, Bolton, Damien
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Radiation Oncology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6453813/
https://www.ncbi.nlm.nih.gov/pubmed/30947480
http://dx.doi.org/10.3857/roj.2018.00556
Descripción
Sumario:PURPOSE: The aim of this retrospective study was to investigate the use of a radiopaque tissue fiducial marker (TFM) in the treatment of prostate cancer patients who undergo post-prostatectomy radiotherapy (PPRT). TFM safety, its role and benefit in quantifying the set-up uncertainties in patients undergoing PPRT image-guided radiotherapy were assessed. MATERIALS AND METHODS: A total of 45 consecutive PPRT patients underwent transperineal implantation of TFM at the level of vesicourethral anastomosis in the retrovesical tissue prior to intensity-modulated radiotherapy. Prostate bed motion was calculated by measuring the position of the TFM relative to the pelvic bony anatomy on daily cone-beam computed tomography. The stability and visibility of the TFM were assessed in the initial 10 patients. RESULTS: No postoperative complications were recorded. A total of 3,500 images were analysed. The calculated prostate bed motion for bony landmark matching relative to TFM were 2.25 mm in the left-right, 5.89 mm in the superior-inferior, and 6.59 mm in the anterior-posterior directions. A significant 36% reduction in the mean volume of rectum receiving 70 Gy (rV(70)) was achieved for a uniform planning target volume (PTV) margin of 7 mm compared with the Australian and New Zealand Faculty of Radiation Oncology Genito-Urinary Group recommended PTV margin of 10 mm. CONCLUSION: The use of TFM was safe and can potentially eliminate set-up errors associated with bony landmark matching, thereby allowing for tighter PTV margins and a consequent favourable reduction in dose delivered to the bladder and rectum, with potential improvements in toxicities.