Cargando…
The use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy
PURPOSE: The aim of this retrospective study was to investigate the use of a radiopaque tissue fiducial marker (TFM) in the treatment of prostate cancer patients who undergo post-prostatectomy radiotherapy (PPRT). TFM safety, its role and benefit in quantifying the set-up uncertainties in patients u...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Radiation Oncology
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6453813/ https://www.ncbi.nlm.nih.gov/pubmed/30947480 http://dx.doi.org/10.3857/roj.2018.00556 |
_version_ | 1783409440115916800 |
---|---|
author | Chao, Michael Ho, Huong Joon, Daryl Lim Chan, Yee Spencer, Sandra Ng, Michael Wasiak, Jason Lawrentschuk, Nathan McMillan, Kevin Sengupta, Shomik Tan, Alwin Koufogiannis, George Cokelek, Margaret Foroudi, Farshad Khong, Tristan-Scott Bolton, Damien |
author_facet | Chao, Michael Ho, Huong Joon, Daryl Lim Chan, Yee Spencer, Sandra Ng, Michael Wasiak, Jason Lawrentschuk, Nathan McMillan, Kevin Sengupta, Shomik Tan, Alwin Koufogiannis, George Cokelek, Margaret Foroudi, Farshad Khong, Tristan-Scott Bolton, Damien |
author_sort | Chao, Michael |
collection | PubMed |
description | PURPOSE: The aim of this retrospective study was to investigate the use of a radiopaque tissue fiducial marker (TFM) in the treatment of prostate cancer patients who undergo post-prostatectomy radiotherapy (PPRT). TFM safety, its role and benefit in quantifying the set-up uncertainties in patients undergoing PPRT image-guided radiotherapy were assessed. MATERIALS AND METHODS: A total of 45 consecutive PPRT patients underwent transperineal implantation of TFM at the level of vesicourethral anastomosis in the retrovesical tissue prior to intensity-modulated radiotherapy. Prostate bed motion was calculated by measuring the position of the TFM relative to the pelvic bony anatomy on daily cone-beam computed tomography. The stability and visibility of the TFM were assessed in the initial 10 patients. RESULTS: No postoperative complications were recorded. A total of 3,500 images were analysed. The calculated prostate bed motion for bony landmark matching relative to TFM were 2.25 mm in the left-right, 5.89 mm in the superior-inferior, and 6.59 mm in the anterior-posterior directions. A significant 36% reduction in the mean volume of rectum receiving 70 Gy (rV(70)) was achieved for a uniform planning target volume (PTV) margin of 7 mm compared with the Australian and New Zealand Faculty of Radiation Oncology Genito-Urinary Group recommended PTV margin of 10 mm. CONCLUSION: The use of TFM was safe and can potentially eliminate set-up errors associated with bony landmark matching, thereby allowing for tighter PTV margins and a consequent favourable reduction in dose delivered to the bladder and rectum, with potential improvements in toxicities. |
format | Online Article Text |
id | pubmed-6453813 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Korean Society for Radiation Oncology |
record_format | MEDLINE/PubMed |
spelling | pubmed-64538132019-04-19 The use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy Chao, Michael Ho, Huong Joon, Daryl Lim Chan, Yee Spencer, Sandra Ng, Michael Wasiak, Jason Lawrentschuk, Nathan McMillan, Kevin Sengupta, Shomik Tan, Alwin Koufogiannis, George Cokelek, Margaret Foroudi, Farshad Khong, Tristan-Scott Bolton, Damien Radiat Oncol J Original Article PURPOSE: The aim of this retrospective study was to investigate the use of a radiopaque tissue fiducial marker (TFM) in the treatment of prostate cancer patients who undergo post-prostatectomy radiotherapy (PPRT). TFM safety, its role and benefit in quantifying the set-up uncertainties in patients undergoing PPRT image-guided radiotherapy were assessed. MATERIALS AND METHODS: A total of 45 consecutive PPRT patients underwent transperineal implantation of TFM at the level of vesicourethral anastomosis in the retrovesical tissue prior to intensity-modulated radiotherapy. Prostate bed motion was calculated by measuring the position of the TFM relative to the pelvic bony anatomy on daily cone-beam computed tomography. The stability and visibility of the TFM were assessed in the initial 10 patients. RESULTS: No postoperative complications were recorded. A total of 3,500 images were analysed. The calculated prostate bed motion for bony landmark matching relative to TFM were 2.25 mm in the left-right, 5.89 mm in the superior-inferior, and 6.59 mm in the anterior-posterior directions. A significant 36% reduction in the mean volume of rectum receiving 70 Gy (rV(70)) was achieved for a uniform planning target volume (PTV) margin of 7 mm compared with the Australian and New Zealand Faculty of Radiation Oncology Genito-Urinary Group recommended PTV margin of 10 mm. CONCLUSION: The use of TFM was safe and can potentially eliminate set-up errors associated with bony landmark matching, thereby allowing for tighter PTV margins and a consequent favourable reduction in dose delivered to the bladder and rectum, with potential improvements in toxicities. The Korean Society for Radiation Oncology 2019-03 2019-03-31 /pmc/articles/PMC6453813/ /pubmed/30947480 http://dx.doi.org/10.3857/roj.2018.00556 Text en Copyright © 2019 The Korean Society for Radiation Oncology This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Chao, Michael Ho, Huong Joon, Daryl Lim Chan, Yee Spencer, Sandra Ng, Michael Wasiak, Jason Lawrentschuk, Nathan McMillan, Kevin Sengupta, Shomik Tan, Alwin Koufogiannis, George Cokelek, Margaret Foroudi, Farshad Khong, Tristan-Scott Bolton, Damien The use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy |
title | The use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy |
title_full | The use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy |
title_fullStr | The use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy |
title_full_unstemmed | The use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy |
title_short | The use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy |
title_sort | use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6453813/ https://www.ncbi.nlm.nih.gov/pubmed/30947480 http://dx.doi.org/10.3857/roj.2018.00556 |
work_keys_str_mv | AT chaomichael theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT hohuong theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT joondaryllim theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT chanyee theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT spencersandra theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT ngmichael theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT wasiakjason theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT lawrentschuknathan theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT mcmillankevin theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT senguptashomik theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT tanalwin theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT koufogiannisgeorge theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT cokelekmargaret theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT foroudifarshad theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT khongtristanscott theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT boltondamien theuseoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT chaomichael useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT hohuong useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT joondaryllim useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT chanyee useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT spencersandra useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT ngmichael useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT wasiakjason useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT lawrentschuknathan useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT mcmillankevin useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT senguptashomik useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT tanalwin useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT koufogiannisgeorge useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT cokelekmargaret useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT foroudifarshad useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT khongtristanscott useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy AT boltondamien useoftissuefiducialmarkersinimprovingtheaccuracyofpostprostatectomyradiotherapy |