Cargando…

Influence of Small, Midi, Medium and Large Fields of View on Accuracy of Linear Measurements in CBCT Imaging: Diagnostic Accuracy Study

AIM: This study aimed to assess the effect of changing the field of view on the dimensional accuracy of CBCT imaging. METHODS: The implant-bone models were randomly numbered from 1 to 13 by the principal researcher, and then on each model at the incisors region three positions were selected and mark...

Descripción completa

Detalles Bibliográficos
Autores principales: Elshenawy, Hanaa, Aly, Wessam, Salah, Nashwa, Nasry, Sherine, Anter, Enas, Ekram, Khalid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Republic of Macedonia 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6454171/
https://www.ncbi.nlm.nih.gov/pubmed/30976357
http://dx.doi.org/10.3889/oamjms.2019.232
_version_ 1783409521466540032
author Elshenawy, Hanaa
Aly, Wessam
Salah, Nashwa
Nasry, Sherine
Anter, Enas
Ekram, Khalid
author_facet Elshenawy, Hanaa
Aly, Wessam
Salah, Nashwa
Nasry, Sherine
Anter, Enas
Ekram, Khalid
author_sort Elshenawy, Hanaa
collection PubMed
description AIM: This study aimed to assess the effect of changing the field of view on the dimensional accuracy of CBCT imaging. METHODS: The implant-bone models were randomly numbered from 1 to 13 by the principal researcher, and then on each model at the incisors region three positions were selected and marked on the model with a permanent blue marker. Then at each marked position three radio-opaque ‘RO’ markers “gutta-percha pieces” were glued on the model surfaces as following; two pieces on the facial surface one occlusally (at the alveolar crest) and one apically (at the inferior border of the model) both were on the same vertical line and perpendicular to the horizontal plane, while the third one was placed on the lingual surface opposing the occlusally placed buccal piece. CBCT examinations of each bone model were performed using Cranex3Dx CBCT (Helsinki, Finland) machine. Each model was scanned four times with standardised tube current and voltage of 12.5 mA and 90 kVp respectively at four different FOVs. The FOVs used were as following: Small FOV: 50 x 50 mm with voxel size 200 µm, Midi FOV: 61 x 78 mm with voxel size 300 µm, Medium FOV: 78 x 78 mm with voxel size 300 µm, Large FOV: 78 x 150 mm with voxel size 350 µm. The reference standard in this study was the real linear measurements that were obtained directly on the implant-bone models using high precision sliding electronic digital calliper with 0-150 mm internal and external measuring range and 0.01 mm resolution accuracy. The index test in the current study was the CBCT linear measurements obtained from CBCT images of implant-bone models using small, midi, medium and large FOVs. RESULTS: The results of this study showed that both medium and large FOVs showed a statistically significant difference, which could be translated into clinical relevance only in thickness measurements. CONCLUSION: The interpretation of these results leads to the assumption that increasing the FOV size together with voxel size could adversely affect the accuracy of CBCT linear measurements, especially when small distances are to be assessed.
format Online
Article
Text
id pubmed-6454171
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Republic of Macedonia
record_format MEDLINE/PubMed
spelling pubmed-64541712019-04-11 Influence of Small, Midi, Medium and Large Fields of View on Accuracy of Linear Measurements in CBCT Imaging: Diagnostic Accuracy Study Elshenawy, Hanaa Aly, Wessam Salah, Nashwa Nasry, Sherine Anter, Enas Ekram, Khalid Open Access Maced J Med Sci Dental Science AIM: This study aimed to assess the effect of changing the field of view on the dimensional accuracy of CBCT imaging. METHODS: The implant-bone models were randomly numbered from 1 to 13 by the principal researcher, and then on each model at the incisors region three positions were selected and marked on the model with a permanent blue marker. Then at each marked position three radio-opaque ‘RO’ markers “gutta-percha pieces” were glued on the model surfaces as following; two pieces on the facial surface one occlusally (at the alveolar crest) and one apically (at the inferior border of the model) both were on the same vertical line and perpendicular to the horizontal plane, while the third one was placed on the lingual surface opposing the occlusally placed buccal piece. CBCT examinations of each bone model were performed using Cranex3Dx CBCT (Helsinki, Finland) machine. Each model was scanned four times with standardised tube current and voltage of 12.5 mA and 90 kVp respectively at four different FOVs. The FOVs used were as following: Small FOV: 50 x 50 mm with voxel size 200 µm, Midi FOV: 61 x 78 mm with voxel size 300 µm, Medium FOV: 78 x 78 mm with voxel size 300 µm, Large FOV: 78 x 150 mm with voxel size 350 µm. The reference standard in this study was the real linear measurements that were obtained directly on the implant-bone models using high precision sliding electronic digital calliper with 0-150 mm internal and external measuring range and 0.01 mm resolution accuracy. The index test in the current study was the CBCT linear measurements obtained from CBCT images of implant-bone models using small, midi, medium and large FOVs. RESULTS: The results of this study showed that both medium and large FOVs showed a statistically significant difference, which could be translated into clinical relevance only in thickness measurements. CONCLUSION: The interpretation of these results leads to the assumption that increasing the FOV size together with voxel size could adversely affect the accuracy of CBCT linear measurements, especially when small distances are to be assessed. Republic of Macedonia 2019-03-29 /pmc/articles/PMC6454171/ /pubmed/30976357 http://dx.doi.org/10.3889/oamjms.2019.232 Text en Copyright: © 2019 Hanaa Elshenawy, Wessam Aly, Nashwa Salah, Sherine Nasry, Enas Anter, Khaled Ekram http://creativecommons.org/licenses/CC BY-NC/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).
spellingShingle Dental Science
Elshenawy, Hanaa
Aly, Wessam
Salah, Nashwa
Nasry, Sherine
Anter, Enas
Ekram, Khalid
Influence of Small, Midi, Medium and Large Fields of View on Accuracy of Linear Measurements in CBCT Imaging: Diagnostic Accuracy Study
title Influence of Small, Midi, Medium and Large Fields of View on Accuracy of Linear Measurements in CBCT Imaging: Diagnostic Accuracy Study
title_full Influence of Small, Midi, Medium and Large Fields of View on Accuracy of Linear Measurements in CBCT Imaging: Diagnostic Accuracy Study
title_fullStr Influence of Small, Midi, Medium and Large Fields of View on Accuracy of Linear Measurements in CBCT Imaging: Diagnostic Accuracy Study
title_full_unstemmed Influence of Small, Midi, Medium and Large Fields of View on Accuracy of Linear Measurements in CBCT Imaging: Diagnostic Accuracy Study
title_short Influence of Small, Midi, Medium and Large Fields of View on Accuracy of Linear Measurements in CBCT Imaging: Diagnostic Accuracy Study
title_sort influence of small, midi, medium and large fields of view on accuracy of linear measurements in cbct imaging: diagnostic accuracy study
topic Dental Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6454171/
https://www.ncbi.nlm.nih.gov/pubmed/30976357
http://dx.doi.org/10.3889/oamjms.2019.232
work_keys_str_mv AT elshenawyhanaa influenceofsmallmidimediumandlargefieldsofviewonaccuracyoflinearmeasurementsincbctimagingdiagnosticaccuracystudy
AT alywessam influenceofsmallmidimediumandlargefieldsofviewonaccuracyoflinearmeasurementsincbctimagingdiagnosticaccuracystudy
AT salahnashwa influenceofsmallmidimediumandlargefieldsofviewonaccuracyoflinearmeasurementsincbctimagingdiagnosticaccuracystudy
AT nasrysherine influenceofsmallmidimediumandlargefieldsofviewonaccuracyoflinearmeasurementsincbctimagingdiagnosticaccuracystudy
AT anterenas influenceofsmallmidimediumandlargefieldsofviewonaccuracyoflinearmeasurementsincbctimagingdiagnosticaccuracystudy
AT ekramkhalid influenceofsmallmidimediumandlargefieldsofviewonaccuracyoflinearmeasurementsincbctimagingdiagnosticaccuracystudy