Cargando…

Measurement properties and performance of an eight-minute submaximal treadmill test in patients with juvenile idiopathic arthritis: a controlled study

BACKGROUND: Poor cardiorespiratory fitness is previously reported in patients with juvenile idiopathic arthritis (JIA) measured both by maximal and submaximal exercise tests, but a submaximal exercise test with acceptable measurement properties is currently lacking for both clinical and research pur...

Descripción completa

Detalles Bibliográficos
Autores principales: Risum, Kristine, Edvardsen, Elisabeth, Selvaag, Anne M., Dagfinrud, Hanne, Sanner, Helga
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6454717/
https://www.ncbi.nlm.nih.gov/pubmed/30961626
http://dx.doi.org/10.1186/s12969-019-0316-7
_version_ 1783409595382759424
author Risum, Kristine
Edvardsen, Elisabeth
Selvaag, Anne M.
Dagfinrud, Hanne
Sanner, Helga
author_facet Risum, Kristine
Edvardsen, Elisabeth
Selvaag, Anne M.
Dagfinrud, Hanne
Sanner, Helga
author_sort Risum, Kristine
collection PubMed
description BACKGROUND: Poor cardiorespiratory fitness is previously reported in patients with juvenile idiopathic arthritis (JIA) measured both by maximal and submaximal exercise tests, but a submaximal exercise test with acceptable measurement properties is currently lacking for both clinical and research purposes in this patient population. The objectives of this study were to evaluate the measurement properties and performance of a submaximal treadmill test in patients with JIA, and to compare the results with those obtained in controls. METHODS: Fifty-nine patients (50 girls), aged 10–16 years, with oligo- (n = 30) and polyarticular (n = 29) JIA, and 59 age- and sex-matched controls performed an eight-minute submaximal treadmill test for estimating peak oxygen uptake (VO(2peak)) followed by a maximal treadmill test measuring VO(2peak) directly. During the submaximal treadmill test, the study participants walked with no inclination at a speed between 3.2–7.2 km/h for four minutes, and then continued to walk at the same speed for four minutes with five % inclination. VO(2peak) was directly measured during a continuous graded exercise test on treadmill until exhaustion. Thirty-seven patients participated in the evaluation of the reliability. Criterion validity and reliability were evaluated with interclass correlation coefficient (ICC); measurement errors by Bland-Altman plot, standard error of measurement and smallest detectable change. RESULTS: In patients with JIA, the ICC (95% CI) for criterion validity was acceptable at group level 0.71 (0.51, 0.82), but not at individual level. The test-retest reliability and inter-rater reliability were acceptable at individual (0.84 (0.71, 0.91) and 0.92 (0.83, 0.96), respectively) and group levels (0.91 (0.83, 0.96) and 0.96 (0.91, 0.98), respectively). The measurement errors (for test-retest reliability/inter-rater reliability) were large. Bland-Altman plots showed no systematic differences, but a large variability for both the validity and reliability. The performance of and estimated VO(2peak) from the submaximal test were not associated with disease variables and were comparable between patients and controls. CONCLUSION: The submaximal treadmill test is valid for use in patients with JIA on group level, but not on individual level. The reliability is acceptable. Due to large measurement errors, the submaximal treadmill test is not optimal for use in daily clinical practice to estimate VO(2peak) in individual patients.
format Online
Article
Text
id pubmed-6454717
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-64547172019-04-19 Measurement properties and performance of an eight-minute submaximal treadmill test in patients with juvenile idiopathic arthritis: a controlled study Risum, Kristine Edvardsen, Elisabeth Selvaag, Anne M. Dagfinrud, Hanne Sanner, Helga Pediatr Rheumatol Online J Research Article BACKGROUND: Poor cardiorespiratory fitness is previously reported in patients with juvenile idiopathic arthritis (JIA) measured both by maximal and submaximal exercise tests, but a submaximal exercise test with acceptable measurement properties is currently lacking for both clinical and research purposes in this patient population. The objectives of this study were to evaluate the measurement properties and performance of a submaximal treadmill test in patients with JIA, and to compare the results with those obtained in controls. METHODS: Fifty-nine patients (50 girls), aged 10–16 years, with oligo- (n = 30) and polyarticular (n = 29) JIA, and 59 age- and sex-matched controls performed an eight-minute submaximal treadmill test for estimating peak oxygen uptake (VO(2peak)) followed by a maximal treadmill test measuring VO(2peak) directly. During the submaximal treadmill test, the study participants walked with no inclination at a speed between 3.2–7.2 km/h for four minutes, and then continued to walk at the same speed for four minutes with five % inclination. VO(2peak) was directly measured during a continuous graded exercise test on treadmill until exhaustion. Thirty-seven patients participated in the evaluation of the reliability. Criterion validity and reliability were evaluated with interclass correlation coefficient (ICC); measurement errors by Bland-Altman plot, standard error of measurement and smallest detectable change. RESULTS: In patients with JIA, the ICC (95% CI) for criterion validity was acceptable at group level 0.71 (0.51, 0.82), but not at individual level. The test-retest reliability and inter-rater reliability were acceptable at individual (0.84 (0.71, 0.91) and 0.92 (0.83, 0.96), respectively) and group levels (0.91 (0.83, 0.96) and 0.96 (0.91, 0.98), respectively). The measurement errors (for test-retest reliability/inter-rater reliability) were large. Bland-Altman plots showed no systematic differences, but a large variability for both the validity and reliability. The performance of and estimated VO(2peak) from the submaximal test were not associated with disease variables and were comparable between patients and controls. CONCLUSION: The submaximal treadmill test is valid for use in patients with JIA on group level, but not on individual level. The reliability is acceptable. Due to large measurement errors, the submaximal treadmill test is not optimal for use in daily clinical practice to estimate VO(2peak) in individual patients. BioMed Central 2019-04-08 /pmc/articles/PMC6454717/ /pubmed/30961626 http://dx.doi.org/10.1186/s12969-019-0316-7 Text en © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Risum, Kristine
Edvardsen, Elisabeth
Selvaag, Anne M.
Dagfinrud, Hanne
Sanner, Helga
Measurement properties and performance of an eight-minute submaximal treadmill test in patients with juvenile idiopathic arthritis: a controlled study
title Measurement properties and performance of an eight-minute submaximal treadmill test in patients with juvenile idiopathic arthritis: a controlled study
title_full Measurement properties and performance of an eight-minute submaximal treadmill test in patients with juvenile idiopathic arthritis: a controlled study
title_fullStr Measurement properties and performance of an eight-minute submaximal treadmill test in patients with juvenile idiopathic arthritis: a controlled study
title_full_unstemmed Measurement properties and performance of an eight-minute submaximal treadmill test in patients with juvenile idiopathic arthritis: a controlled study
title_short Measurement properties and performance of an eight-minute submaximal treadmill test in patients with juvenile idiopathic arthritis: a controlled study
title_sort measurement properties and performance of an eight-minute submaximal treadmill test in patients with juvenile idiopathic arthritis: a controlled study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6454717/
https://www.ncbi.nlm.nih.gov/pubmed/30961626
http://dx.doi.org/10.1186/s12969-019-0316-7
work_keys_str_mv AT risumkristine measurementpropertiesandperformanceofaneightminutesubmaximaltreadmilltestinpatientswithjuvenileidiopathicarthritisacontrolledstudy
AT edvardsenelisabeth measurementpropertiesandperformanceofaneightminutesubmaximaltreadmilltestinpatientswithjuvenileidiopathicarthritisacontrolledstudy
AT selvaagannem measurementpropertiesandperformanceofaneightminutesubmaximaltreadmilltestinpatientswithjuvenileidiopathicarthritisacontrolledstudy
AT dagfinrudhanne measurementpropertiesandperformanceofaneightminutesubmaximaltreadmilltestinpatientswithjuvenileidiopathicarthritisacontrolledstudy
AT sannerhelga measurementpropertiesandperformanceofaneightminutesubmaximaltreadmilltestinpatientswithjuvenileidiopathicarthritisacontrolledstudy