Cargando…
Intramedullary sealing with a bone plug in total knee arthroplasty to reduce blood loss: a meta-analysis of randomized controlled trials
BACKGROUND: An intramedullary guide is an instrument that surgeons use to align the distal femoral cut. The opening may become a channel that drains intramedullary blood to the knee joint after surgery if left open during surgery. The authors aimed to evaluate the effects of an intramedullary bone p...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6454759/ https://www.ncbi.nlm.nih.gov/pubmed/30961640 http://dx.doi.org/10.1186/s13018-019-1141-x |
_version_ | 1783409605649367040 |
---|---|
author | Yuenyongviwat, Varah Tuntarattanapong, Pakjai Iamthanaporn, Khanin Hongnaparak, Theerawit Tangtrakulwanich, Boonsin |
author_facet | Yuenyongviwat, Varah Tuntarattanapong, Pakjai Iamthanaporn, Khanin Hongnaparak, Theerawit Tangtrakulwanich, Boonsin |
author_sort | Yuenyongviwat, Varah |
collection | PubMed |
description | BACKGROUND: An intramedullary guide is an instrument that surgeons use to align the distal femoral cut. The opening may become a channel that drains intramedullary blood to the knee joint after surgery if left open during surgery. The authors aimed to evaluate the effects of an intramedullary bone plug with respect to postoperative blood loss from a meta-analysis. METHODS: The authors performed a systematic review and meta-analysis to compare a sealed opening using an intramedullary bone plug with no bone plug. PubMed, Ovid, Embase, and Cochrane Library were used to identify all publications before May 2018. All of the included studies were evaluated for bias and heterogeneity. RESULTS: Six hundred and thirty-six patients from four randomized controlled trials were included in this meta-analysis. The pooled results demonstrated that patients with intramedullary plug had lower rates of blood transfusion and lower level of reduced postoperative hemoglobin than patients in whom the intramedullary canal was not plugged. DISCUSSION: This meta-analysis demonstrated the benefit of intramedullary sealing with a bone plug in total knee arthroplasty with respect to decreased postoperative blood loss. |
format | Online Article Text |
id | pubmed-6454759 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-64547592019-04-19 Intramedullary sealing with a bone plug in total knee arthroplasty to reduce blood loss: a meta-analysis of randomized controlled trials Yuenyongviwat, Varah Tuntarattanapong, Pakjai Iamthanaporn, Khanin Hongnaparak, Theerawit Tangtrakulwanich, Boonsin J Orthop Surg Res Systematic Review BACKGROUND: An intramedullary guide is an instrument that surgeons use to align the distal femoral cut. The opening may become a channel that drains intramedullary blood to the knee joint after surgery if left open during surgery. The authors aimed to evaluate the effects of an intramedullary bone plug with respect to postoperative blood loss from a meta-analysis. METHODS: The authors performed a systematic review and meta-analysis to compare a sealed opening using an intramedullary bone plug with no bone plug. PubMed, Ovid, Embase, and Cochrane Library were used to identify all publications before May 2018. All of the included studies were evaluated for bias and heterogeneity. RESULTS: Six hundred and thirty-six patients from four randomized controlled trials were included in this meta-analysis. The pooled results demonstrated that patients with intramedullary plug had lower rates of blood transfusion and lower level of reduced postoperative hemoglobin than patients in whom the intramedullary canal was not plugged. DISCUSSION: This meta-analysis demonstrated the benefit of intramedullary sealing with a bone plug in total knee arthroplasty with respect to decreased postoperative blood loss. BioMed Central 2019-04-08 /pmc/articles/PMC6454759/ /pubmed/30961640 http://dx.doi.org/10.1186/s13018-019-1141-x Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Systematic Review Yuenyongviwat, Varah Tuntarattanapong, Pakjai Iamthanaporn, Khanin Hongnaparak, Theerawit Tangtrakulwanich, Boonsin Intramedullary sealing with a bone plug in total knee arthroplasty to reduce blood loss: a meta-analysis of randomized controlled trials |
title | Intramedullary sealing with a bone plug in total knee arthroplasty to reduce blood loss: a meta-analysis of randomized controlled trials |
title_full | Intramedullary sealing with a bone plug in total knee arthroplasty to reduce blood loss: a meta-analysis of randomized controlled trials |
title_fullStr | Intramedullary sealing with a bone plug in total knee arthroplasty to reduce blood loss: a meta-analysis of randomized controlled trials |
title_full_unstemmed | Intramedullary sealing with a bone plug in total knee arthroplasty to reduce blood loss: a meta-analysis of randomized controlled trials |
title_short | Intramedullary sealing with a bone plug in total knee arthroplasty to reduce blood loss: a meta-analysis of randomized controlled trials |
title_sort | intramedullary sealing with a bone plug in total knee arthroplasty to reduce blood loss: a meta-analysis of randomized controlled trials |
topic | Systematic Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6454759/ https://www.ncbi.nlm.nih.gov/pubmed/30961640 http://dx.doi.org/10.1186/s13018-019-1141-x |
work_keys_str_mv | AT yuenyongviwatvarah intramedullarysealingwithaboneplugintotalkneearthroplastytoreducebloodlossametaanalysisofrandomizedcontrolledtrials AT tuntarattanapongpakjai intramedullarysealingwithaboneplugintotalkneearthroplastytoreducebloodlossametaanalysisofrandomizedcontrolledtrials AT iamthanapornkhanin intramedullarysealingwithaboneplugintotalkneearthroplastytoreducebloodlossametaanalysisofrandomizedcontrolledtrials AT hongnaparaktheerawit intramedullarysealingwithaboneplugintotalkneearthroplastytoreducebloodlossametaanalysisofrandomizedcontrolledtrials AT tangtrakulwanichboonsin intramedullarysealingwithaboneplugintotalkneearthroplastytoreducebloodlossametaanalysisofrandomizedcontrolledtrials |