Cargando…

Validation of Alternative Methods for Detecting Meibomian Gland Dropout Without an Infrared Light System: Red Filter for Simple and Effective Meibography

PURPOSE: To evaluate the validity and reliability of alternative methods for evaluating meibomian gland (MG) dropout without using an infrared light system: red-filtered or isolated red-channel images (RCIs) of the everted eyelid. METHODS: We evaluated MG dropout in the everted upper and lower eyeli...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Sang-Mok, Park, Inwon, Goo, Yong Ho, Choi, Dongchul, Shin, Min Chul, Kim, Eun Chul, Alkwikbi, Hassan Fallaj, Kim, Man Soo, Hwang, Ho Sik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cornea 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6455092/
https://www.ncbi.nlm.nih.gov/pubmed/30789441
http://dx.doi.org/10.1097/ICO.0000000000001892
_version_ 1783409655787028480
author Lee, Sang-Mok
Park, Inwon
Goo, Yong Ho
Choi, Dongchul
Shin, Min Chul
Kim, Eun Chul
Alkwikbi, Hassan Fallaj
Kim, Man Soo
Hwang, Ho Sik
author_facet Lee, Sang-Mok
Park, Inwon
Goo, Yong Ho
Choi, Dongchul
Shin, Min Chul
Kim, Eun Chul
Alkwikbi, Hassan Fallaj
Kim, Man Soo
Hwang, Ho Sik
author_sort Lee, Sang-Mok
collection PubMed
description PURPOSE: To evaluate the validity and reliability of alternative methods for evaluating meibomian gland (MG) dropout without using an infrared light system: red-filtered or isolated red-channel images (RCIs) of the everted eyelid. METHODS: We evaluated MG dropout in the everted upper and lower eyelids of 125 eyes of 64 patients with good-quality infrared meibography images (IMIs) and color digital photographs with and without a red filter. Red-filtered images (RFIs) were converted to black and white and adjusted for contrast/brightness [adjusted red-filtered images (aRFIs)]. RCIs were computationally isolated from color digital photographs obtained without a red filter. After randomization, the total meiboscore (0–6) was evaluated by 2 independent evaluators (interobserver reliability) masked to the image origin, and again after a 30-day interval (intraobserver reliability). RESULTS: The meiboscores evaluated using the RFI, aRFI, and RCI were strongly positively correlated with those evaluated using the IMI (RFI: ρ = 0.788; aRFI: ρ = 0.735; RCI: ρ = 0.630; all P < 0.001, Spearman correlation analysis). Linear-weighted κ-values (κ(w)) showed substantial agreement between the RFI and IMI (κ(w) = 0.676, 95% CI = 0.594–0.759). The RFI had substantial intraobserver reliability (κ(w) = 0.735, 95% CI = 0.685–0.785) and moderate interobserver reliability (κ(w) = 0.467, 95% CI = 0.371–0.563). Computational adjustment of RFIs did not enhance the validity or reliability, and RCIs had limitations in some cases. CONCLUSIONS: MGs were successfully visualized using a red filter on a slit lamp and showed substantial agreement with visualization using the standard infrared method. Although interobserver reliability was only moderate, this alternative technique may be useful for evaluating MG dropout when an infrared meibography device is not available.
format Online
Article
Text
id pubmed-6455092
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Cornea
record_format MEDLINE/PubMed
spelling pubmed-64550922019-05-01 Validation of Alternative Methods for Detecting Meibomian Gland Dropout Without an Infrared Light System: Red Filter for Simple and Effective Meibography Lee, Sang-Mok Park, Inwon Goo, Yong Ho Choi, Dongchul Shin, Min Chul Kim, Eun Chul Alkwikbi, Hassan Fallaj Kim, Man Soo Hwang, Ho Sik Cornea Clinical Science PURPOSE: To evaluate the validity and reliability of alternative methods for evaluating meibomian gland (MG) dropout without using an infrared light system: red-filtered or isolated red-channel images (RCIs) of the everted eyelid. METHODS: We evaluated MG dropout in the everted upper and lower eyelids of 125 eyes of 64 patients with good-quality infrared meibography images (IMIs) and color digital photographs with and without a red filter. Red-filtered images (RFIs) were converted to black and white and adjusted for contrast/brightness [adjusted red-filtered images (aRFIs)]. RCIs were computationally isolated from color digital photographs obtained without a red filter. After randomization, the total meiboscore (0–6) was evaluated by 2 independent evaluators (interobserver reliability) masked to the image origin, and again after a 30-day interval (intraobserver reliability). RESULTS: The meiboscores evaluated using the RFI, aRFI, and RCI were strongly positively correlated with those evaluated using the IMI (RFI: ρ = 0.788; aRFI: ρ = 0.735; RCI: ρ = 0.630; all P < 0.001, Spearman correlation analysis). Linear-weighted κ-values (κ(w)) showed substantial agreement between the RFI and IMI (κ(w) = 0.676, 95% CI = 0.594–0.759). The RFI had substantial intraobserver reliability (κ(w) = 0.735, 95% CI = 0.685–0.785) and moderate interobserver reliability (κ(w) = 0.467, 95% CI = 0.371–0.563). Computational adjustment of RFIs did not enhance the validity or reliability, and RCIs had limitations in some cases. CONCLUSIONS: MGs were successfully visualized using a red filter on a slit lamp and showed substantial agreement with visualization using the standard infrared method. Although interobserver reliability was only moderate, this alternative technique may be useful for evaluating MG dropout when an infrared meibography device is not available. Cornea 2019-05 2019-02-15 /pmc/articles/PMC6455092/ /pubmed/30789441 http://dx.doi.org/10.1097/ICO.0000000000001892 Text en Copyright © 2019 The Author(s). Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Clinical Science
Lee, Sang-Mok
Park, Inwon
Goo, Yong Ho
Choi, Dongchul
Shin, Min Chul
Kim, Eun Chul
Alkwikbi, Hassan Fallaj
Kim, Man Soo
Hwang, Ho Sik
Validation of Alternative Methods for Detecting Meibomian Gland Dropout Without an Infrared Light System: Red Filter for Simple and Effective Meibography
title Validation of Alternative Methods for Detecting Meibomian Gland Dropout Without an Infrared Light System: Red Filter for Simple and Effective Meibography
title_full Validation of Alternative Methods for Detecting Meibomian Gland Dropout Without an Infrared Light System: Red Filter for Simple and Effective Meibography
title_fullStr Validation of Alternative Methods for Detecting Meibomian Gland Dropout Without an Infrared Light System: Red Filter for Simple and Effective Meibography
title_full_unstemmed Validation of Alternative Methods for Detecting Meibomian Gland Dropout Without an Infrared Light System: Red Filter for Simple and Effective Meibography
title_short Validation of Alternative Methods for Detecting Meibomian Gland Dropout Without an Infrared Light System: Red Filter for Simple and Effective Meibography
title_sort validation of alternative methods for detecting meibomian gland dropout without an infrared light system: red filter for simple and effective meibography
topic Clinical Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6455092/
https://www.ncbi.nlm.nih.gov/pubmed/30789441
http://dx.doi.org/10.1097/ICO.0000000000001892
work_keys_str_mv AT leesangmok validationofalternativemethodsfordetectingmeibomianglanddropoutwithoutaninfraredlightsystemredfilterforsimpleandeffectivemeibography
AT parkinwon validationofalternativemethodsfordetectingmeibomianglanddropoutwithoutaninfraredlightsystemredfilterforsimpleandeffectivemeibography
AT gooyongho validationofalternativemethodsfordetectingmeibomianglanddropoutwithoutaninfraredlightsystemredfilterforsimpleandeffectivemeibography
AT choidongchul validationofalternativemethodsfordetectingmeibomianglanddropoutwithoutaninfraredlightsystemredfilterforsimpleandeffectivemeibography
AT shinminchul validationofalternativemethodsfordetectingmeibomianglanddropoutwithoutaninfraredlightsystemredfilterforsimpleandeffectivemeibography
AT kimeunchul validationofalternativemethodsfordetectingmeibomianglanddropoutwithoutaninfraredlightsystemredfilterforsimpleandeffectivemeibography
AT alkwikbihassanfallaj validationofalternativemethodsfordetectingmeibomianglanddropoutwithoutaninfraredlightsystemredfilterforsimpleandeffectivemeibography
AT kimmansoo validationofalternativemethodsfordetectingmeibomianglanddropoutwithoutaninfraredlightsystemredfilterforsimpleandeffectivemeibography
AT hwanghosik validationofalternativemethodsfordetectingmeibomianglanddropoutwithoutaninfraredlightsystemredfilterforsimpleandeffectivemeibography