Cargando…
Effects of positive end-expiratory pressure on intraocular pressure and optic nerve sheath diameter in robot-assisted laparoscopic radical prostatectomy: A randomized, clinical trial
BACKGROUND: There has been no study of the effect of post end-expiratory pressure (PEEP) on intraocular or intracranial pressure during pneumoperitoneum with steep Trendelenburg positioning. We investigated the effects of 5 cmH(2)O of PEEP on intraocular pressure and optic nerve sheath diameter as a...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6455825/ https://www.ncbi.nlm.nih.gov/pubmed/30946349 http://dx.doi.org/10.1097/MD.0000000000015051 |
_version_ | 1783409683480969216 |
---|---|
author | You, Ann Hee Song, Young Kim, Do-Hyeong Suh, Jiwoo Baek, Ji Won Han, Dong Woo |
author_facet | You, Ann Hee Song, Young Kim, Do-Hyeong Suh, Jiwoo Baek, Ji Won Han, Dong Woo |
author_sort | You, Ann Hee |
collection | PubMed |
description | BACKGROUND: There has been no study of the effect of post end-expiratory pressure (PEEP) on intraocular or intracranial pressure during pneumoperitoneum with steep Trendelenburg positioning. We investigated the effects of 5 cmH(2)O of PEEP on intraocular pressure and optic nerve sheath diameter as a surrogate for intracranial pressure in robot-assisted laparoscopic radical prostatectomy. METHODS: Fifty patients scheduled for robot-assisted laparoscopic radical prostatectomy were divided into a zero-PEEP (ZEEP) group and a 5 cmH(2)O of PEEP (PEEP) group. Intraocular pressure, optic nerve sheath diameter, and respiratory and hemodynamic parameters were measured before induction (T0), 10 minutes after induction of general anesthesia in the supine position before CO(2) insufflation (T1), 5 minutes (T2), and 30 minutes (T3) after steep Trendelenburg positioning with pneumoperitoneum, after desufflation of pneumoperitoneum in the supine position (T4), and after 30 minutes in the recovery room postoperatively (T5). RESULTS: There was no significant difference in intraocular pressure or optic nerve sheath diameter between the groups during the study. The partial pressure of arterial oxygen and dynamic lung compliance at T1, T2, T3, and T4 were significantly higher in the PEEP than in the ZEEP group. There was no difference in mean arterial pressure or heart rate between groups at any time. CONCLUSION: Applying 5 cmH(2)O of PEEP did not increase intraocular pressure or optic nerve sheath diameter during pneumoperitoneum with steep Trendelenburg positioning in robot-assisted laparoscopic radical prostatectomy. These results suggest that low PEEP can be safely applied during surgery with pneumoperitoneum and steep Trendelenburg positioning in patients without preexisting eye disease and brain pathology. |
format | Online Article Text |
id | pubmed-6455825 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-64558252019-05-29 Effects of positive end-expiratory pressure on intraocular pressure and optic nerve sheath diameter in robot-assisted laparoscopic radical prostatectomy: A randomized, clinical trial You, Ann Hee Song, Young Kim, Do-Hyeong Suh, Jiwoo Baek, Ji Won Han, Dong Woo Medicine (Baltimore) Research Article BACKGROUND: There has been no study of the effect of post end-expiratory pressure (PEEP) on intraocular or intracranial pressure during pneumoperitoneum with steep Trendelenburg positioning. We investigated the effects of 5 cmH(2)O of PEEP on intraocular pressure and optic nerve sheath diameter as a surrogate for intracranial pressure in robot-assisted laparoscopic radical prostatectomy. METHODS: Fifty patients scheduled for robot-assisted laparoscopic radical prostatectomy were divided into a zero-PEEP (ZEEP) group and a 5 cmH(2)O of PEEP (PEEP) group. Intraocular pressure, optic nerve sheath diameter, and respiratory and hemodynamic parameters were measured before induction (T0), 10 minutes after induction of general anesthesia in the supine position before CO(2) insufflation (T1), 5 minutes (T2), and 30 minutes (T3) after steep Trendelenburg positioning with pneumoperitoneum, after desufflation of pneumoperitoneum in the supine position (T4), and after 30 minutes in the recovery room postoperatively (T5). RESULTS: There was no significant difference in intraocular pressure or optic nerve sheath diameter between the groups during the study. The partial pressure of arterial oxygen and dynamic lung compliance at T1, T2, T3, and T4 were significantly higher in the PEEP than in the ZEEP group. There was no difference in mean arterial pressure or heart rate between groups at any time. CONCLUSION: Applying 5 cmH(2)O of PEEP did not increase intraocular pressure or optic nerve sheath diameter during pneumoperitoneum with steep Trendelenburg positioning in robot-assisted laparoscopic radical prostatectomy. These results suggest that low PEEP can be safely applied during surgery with pneumoperitoneum and steep Trendelenburg positioning in patients without preexisting eye disease and brain pathology. Wolters Kluwer Health 2019-04-05 /pmc/articles/PMC6455825/ /pubmed/30946349 http://dx.doi.org/10.1097/MD.0000000000015051 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0 |
spellingShingle | Research Article You, Ann Hee Song, Young Kim, Do-Hyeong Suh, Jiwoo Baek, Ji Won Han, Dong Woo Effects of positive end-expiratory pressure on intraocular pressure and optic nerve sheath diameter in robot-assisted laparoscopic radical prostatectomy: A randomized, clinical trial |
title | Effects of positive end-expiratory pressure on intraocular pressure and optic nerve sheath diameter in robot-assisted laparoscopic radical prostatectomy: A randomized, clinical trial |
title_full | Effects of positive end-expiratory pressure on intraocular pressure and optic nerve sheath diameter in robot-assisted laparoscopic radical prostatectomy: A randomized, clinical trial |
title_fullStr | Effects of positive end-expiratory pressure on intraocular pressure and optic nerve sheath diameter in robot-assisted laparoscopic radical prostatectomy: A randomized, clinical trial |
title_full_unstemmed | Effects of positive end-expiratory pressure on intraocular pressure and optic nerve sheath diameter in robot-assisted laparoscopic radical prostatectomy: A randomized, clinical trial |
title_short | Effects of positive end-expiratory pressure on intraocular pressure and optic nerve sheath diameter in robot-assisted laparoscopic radical prostatectomy: A randomized, clinical trial |
title_sort | effects of positive end-expiratory pressure on intraocular pressure and optic nerve sheath diameter in robot-assisted laparoscopic radical prostatectomy: a randomized, clinical trial |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6455825/ https://www.ncbi.nlm.nih.gov/pubmed/30946349 http://dx.doi.org/10.1097/MD.0000000000015051 |
work_keys_str_mv | AT youannhee effectsofpositiveendexpiratorypressureonintraocularpressureandopticnervesheathdiameterinrobotassistedlaparoscopicradicalprostatectomyarandomizedclinicaltrial AT songyoung effectsofpositiveendexpiratorypressureonintraocularpressureandopticnervesheathdiameterinrobotassistedlaparoscopicradicalprostatectomyarandomizedclinicaltrial AT kimdohyeong effectsofpositiveendexpiratorypressureonintraocularpressureandopticnervesheathdiameterinrobotassistedlaparoscopicradicalprostatectomyarandomizedclinicaltrial AT suhjiwoo effectsofpositiveendexpiratorypressureonintraocularpressureandopticnervesheathdiameterinrobotassistedlaparoscopicradicalprostatectomyarandomizedclinicaltrial AT baekjiwon effectsofpositiveendexpiratorypressureonintraocularpressureandopticnervesheathdiameterinrobotassistedlaparoscopicradicalprostatectomyarandomizedclinicaltrial AT handongwoo effectsofpositiveendexpiratorypressureonintraocularpressureandopticnervesheathdiameterinrobotassistedlaparoscopicradicalprostatectomyarandomizedclinicaltrial |