Cargando…

Novel treatment of severe radial artery spasm using “homemade sheathless technique”: A case report

RATIONALE: Transradial access (TRA) is common for cardiac catheterization, but radial artery spasm (RAS) is suggested to be highlighted. Severe radical artery spasm could be solved by a relative novel approach called “sheathless technique,” using a Tiger diagnostic catheter. PATIENT CONCERNS: A 73-y...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Zaiyong, Xie, Qiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6456032/
https://www.ncbi.nlm.nih.gov/pubmed/30921221
http://dx.doi.org/10.1097/MD.0000000000015008
_version_ 1783409699185491968
author Zhang, Zaiyong
Xie, Qiang
author_facet Zhang, Zaiyong
Xie, Qiang
author_sort Zhang, Zaiyong
collection PubMed
description RATIONALE: Transradial access (TRA) is common for cardiac catheterization, but radial artery spasm (RAS) is suggested to be highlighted. Severe radical artery spasm could be solved by a relative novel approach called “sheathless technique,” using a Tiger diagnostic catheter. PATIENT CONCERNS: A 73-year-old woman presented to our institution with a recurrent feeling of discomfort in her chest. Her electrocardiogram showed ST segment depression. Her medical history indicated arterial hypertension, diabetes, and chronic renal failure. She was on hemodialysis for 5 years for the management of renal problems. Five stents were implanted from femoral access in another hospital via 2 percutaneous coronary interventions. The patient agreed to angiography this time and wanted a more comfortable solution. DIAGNOSIS: Recurrent exertional angina was confirmed based on the chief complaint, electrocardiogram, and history. INTERVENTIONS: After a successful radial artery puncture, a 6F arterial sheath pipe and a 5F Tiger diagnostic ductus could only advance slightly because of the RAS. Glonoin and verapamil functioned with the help of the radial sheath, and systemic nitroglycerin was applied later but had a negative outcome. Warm covers were positioned on the antebrachium, but no relief was reported. The “homemade sheathless technique” was applied. The 5F tube was held, and the 6F sheath was withdrawn. A blade was used to damage the sheath in reverse, and the excess sheath tube was removed. OUTCOMES: The diagnostic catheter was successfully advanced to the ascending aorta, enabling left main and right coronary engagement and angiography. No significant coronary lesion was observed. The patient was discharged 3 days after angiography. Moreover, no complications were observed. A follow-up for 1 month after discharge also showed no complications. LESSONS: Severe RAS causing failure of TRA is frequent in the transradial catheterization procedure. The sheathless technique may be useful in relieving spasm when other measures fail.
format Online
Article
Text
id pubmed-6456032
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-64560322019-05-29 Novel treatment of severe radial artery spasm using “homemade sheathless technique”: A case report Zhang, Zaiyong Xie, Qiang Medicine (Baltimore) Research Article RATIONALE: Transradial access (TRA) is common for cardiac catheterization, but radial artery spasm (RAS) is suggested to be highlighted. Severe radical artery spasm could be solved by a relative novel approach called “sheathless technique,” using a Tiger diagnostic catheter. PATIENT CONCERNS: A 73-year-old woman presented to our institution with a recurrent feeling of discomfort in her chest. Her electrocardiogram showed ST segment depression. Her medical history indicated arterial hypertension, diabetes, and chronic renal failure. She was on hemodialysis for 5 years for the management of renal problems. Five stents were implanted from femoral access in another hospital via 2 percutaneous coronary interventions. The patient agreed to angiography this time and wanted a more comfortable solution. DIAGNOSIS: Recurrent exertional angina was confirmed based on the chief complaint, electrocardiogram, and history. INTERVENTIONS: After a successful radial artery puncture, a 6F arterial sheath pipe and a 5F Tiger diagnostic ductus could only advance slightly because of the RAS. Glonoin and verapamil functioned with the help of the radial sheath, and systemic nitroglycerin was applied later but had a negative outcome. Warm covers were positioned on the antebrachium, but no relief was reported. The “homemade sheathless technique” was applied. The 5F tube was held, and the 6F sheath was withdrawn. A blade was used to damage the sheath in reverse, and the excess sheath tube was removed. OUTCOMES: The diagnostic catheter was successfully advanced to the ascending aorta, enabling left main and right coronary engagement and angiography. No significant coronary lesion was observed. The patient was discharged 3 days after angiography. Moreover, no complications were observed. A follow-up for 1 month after discharge also showed no complications. LESSONS: Severe RAS causing failure of TRA is frequent in the transradial catheterization procedure. The sheathless technique may be useful in relieving spasm when other measures fail. Wolters Kluwer Health 2019-03-15 /pmc/articles/PMC6456032/ /pubmed/30921221 http://dx.doi.org/10.1097/MD.0000000000015008 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0
spellingShingle Research Article
Zhang, Zaiyong
Xie, Qiang
Novel treatment of severe radial artery spasm using “homemade sheathless technique”: A case report
title Novel treatment of severe radial artery spasm using “homemade sheathless technique”: A case report
title_full Novel treatment of severe radial artery spasm using “homemade sheathless technique”: A case report
title_fullStr Novel treatment of severe radial artery spasm using “homemade sheathless technique”: A case report
title_full_unstemmed Novel treatment of severe radial artery spasm using “homemade sheathless technique”: A case report
title_short Novel treatment of severe radial artery spasm using “homemade sheathless technique”: A case report
title_sort novel treatment of severe radial artery spasm using “homemade sheathless technique”: a case report
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6456032/
https://www.ncbi.nlm.nih.gov/pubmed/30921221
http://dx.doi.org/10.1097/MD.0000000000015008
work_keys_str_mv AT zhangzaiyong noveltreatmentofsevereradialarteryspasmusinghomemadesheathlesstechniqueacasereport
AT xieqiang noveltreatmentofsevereradialarteryspasmusinghomemadesheathlesstechniqueacasereport