A method for early detection and identification of fungal contamination of building materials using e-nose

The aim of the study was to develop a method for early detection and identification of fungal contamination of building materials using an electronic nose. Therefore, the laboratory experiments based on the analysis of the air in the vicinity of fungal isolates potentially found in the building mate...

Descripción completa

Detalles Bibliográficos
Autores principales: Suchorab, Zbigniew, Frąc, Magdalena, Guz, Łukasz, Oszust, Karolina, Łagód, Grzegorz, Gryta, Agata, Bilińska-Wielgus, Nina, Czerwiński, Jacek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6456197/
https://www.ncbi.nlm.nih.gov/pubmed/30964926
http://dx.doi.org/10.1371/journal.pone.0215179
_version_ 1783409728305496064
author Suchorab, Zbigniew
Frąc, Magdalena
Guz, Łukasz
Oszust, Karolina
Łagód, Grzegorz
Gryta, Agata
Bilińska-Wielgus, Nina
Czerwiński, Jacek
author_facet Suchorab, Zbigniew
Frąc, Magdalena
Guz, Łukasz
Oszust, Karolina
Łagód, Grzegorz
Gryta, Agata
Bilińska-Wielgus, Nina
Czerwiński, Jacek
author_sort Suchorab, Zbigniew
collection PubMed
description The aim of the study was to develop a method for early detection and identification of fungal contamination of building materials using an electronic nose. Therefore, the laboratory experiments based on the analysis of the air in the vicinity of fungal isolates potentially found in the building materials were performed. The results revealed that the employed gas sensors array consisting of MOS-type sensors enables the detection of the differences among the examined samples of fungi and distinguishing between the non-contaminated and contaminated samples, shortly after fungal contamination occurs. Electronic nose readouts were analysed using Principal Component Analysis and the results were verified with standard chromatographic analysis by means of SPME-GC/MS method, which proved that gas sensors array can be applied for early detection of fungal contamination.
format Online
Article
Text
id pubmed-6456197
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-64561972019-05-03 A method for early detection and identification of fungal contamination of building materials using e-nose Suchorab, Zbigniew Frąc, Magdalena Guz, Łukasz Oszust, Karolina Łagód, Grzegorz Gryta, Agata Bilińska-Wielgus, Nina Czerwiński, Jacek PLoS One Research Article The aim of the study was to develop a method for early detection and identification of fungal contamination of building materials using an electronic nose. Therefore, the laboratory experiments based on the analysis of the air in the vicinity of fungal isolates potentially found in the building materials were performed. The results revealed that the employed gas sensors array consisting of MOS-type sensors enables the detection of the differences among the examined samples of fungi and distinguishing between the non-contaminated and contaminated samples, shortly after fungal contamination occurs. Electronic nose readouts were analysed using Principal Component Analysis and the results were verified with standard chromatographic analysis by means of SPME-GC/MS method, which proved that gas sensors array can be applied for early detection of fungal contamination. Public Library of Science 2019-04-09 /pmc/articles/PMC6456197/ /pubmed/30964926 http://dx.doi.org/10.1371/journal.pone.0215179 Text en © 2019 Suchorab et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Suchorab, Zbigniew
Frąc, Magdalena
Guz, Łukasz
Oszust, Karolina
Łagód, Grzegorz
Gryta, Agata
Bilińska-Wielgus, Nina
Czerwiński, Jacek
A method for early detection and identification of fungal contamination of building materials using e-nose
title A method for early detection and identification of fungal contamination of building materials using e-nose
title_full A method for early detection and identification of fungal contamination of building materials using e-nose
title_fullStr A method for early detection and identification of fungal contamination of building materials using e-nose
title_full_unstemmed A method for early detection and identification of fungal contamination of building materials using e-nose
title_short A method for early detection and identification of fungal contamination of building materials using e-nose
title_sort method for early detection and identification of fungal contamination of building materials using e-nose
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6456197/
https://www.ncbi.nlm.nih.gov/pubmed/30964926
http://dx.doi.org/10.1371/journal.pone.0215179
work_keys_str_mv AT suchorabzbigniew amethodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT fracmagdalena amethodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT guzłukasz amethodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT oszustkarolina amethodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT łagodgrzegorz amethodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT grytaagata amethodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT bilinskawielgusnina amethodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT czerwinskijacek amethodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT suchorabzbigniew methodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT fracmagdalena methodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT guzłukasz methodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT oszustkarolina methodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT łagodgrzegorz methodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT grytaagata methodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT bilinskawielgusnina methodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose
AT czerwinskijacek methodforearlydetectionandidentificationoffungalcontaminationofbuildingmaterialsusingenose