Cargando…
Pulmonary artery stenting in a patient with Takayasu’s arteritis using a novel balloon-expandable covered stent
Patients with Takayasu’s arteritis have pulmonary artery involvement more commonly than previously appreciated. The majority of these lesions are in segmental or sub-segmental arteries, but there are some patients who have severe stenosis of the main pulmonary arteries. Interventional treatment of t...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6457077/ https://www.ncbi.nlm.nih.gov/pubmed/31007921 http://dx.doi.org/10.1177/2050313X19841955 |
_version_ | 1783409858353037312 |
---|---|
author | Weinstock, Barry S Haim, Yitzhak Daniel |
author_facet | Weinstock, Barry S Haim, Yitzhak Daniel |
author_sort | Weinstock, Barry S |
collection | PubMed |
description | Patients with Takayasu’s arteritis have pulmonary artery involvement more commonly than previously appreciated. The majority of these lesions are in segmental or sub-segmental arteries, but there are some patients who have severe stenosis of the main pulmonary arteries. Interventional treatment of these patients is technically feasible, but there are only limited case reports describing such intervention. Balloon angioplasty and stenting in these lesions often require high pressure inflations to achieve adequate results and thus has increased risk due to the possibility of pulmonary artery rupture. The recently approved Viabahn BX balloon-expandable covered stent may be an optimal device for main pulmonary artery stenosis as it is relatively low profile, can be over-expanded to large vessel diameter without compromise or disruption of the polytetrafluoroethylene covering and virtually eliminates the risk of catastrophic pulmonary artery rupture. We report here the first known use of this novel stent for treatment of severe pulmonary artery stenosis. |
format | Online Article Text |
id | pubmed-6457077 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-64570772019-04-19 Pulmonary artery stenting in a patient with Takayasu’s arteritis using a novel balloon-expandable covered stent Weinstock, Barry S Haim, Yitzhak Daniel SAGE Open Med Case Rep Case Report Patients with Takayasu’s arteritis have pulmonary artery involvement more commonly than previously appreciated. The majority of these lesions are in segmental or sub-segmental arteries, but there are some patients who have severe stenosis of the main pulmonary arteries. Interventional treatment of these patients is technically feasible, but there are only limited case reports describing such intervention. Balloon angioplasty and stenting in these lesions often require high pressure inflations to achieve adequate results and thus has increased risk due to the possibility of pulmonary artery rupture. The recently approved Viabahn BX balloon-expandable covered stent may be an optimal device for main pulmonary artery stenosis as it is relatively low profile, can be over-expanded to large vessel diameter without compromise or disruption of the polytetrafluoroethylene covering and virtually eliminates the risk of catastrophic pulmonary artery rupture. We report here the first known use of this novel stent for treatment of severe pulmonary artery stenosis. SAGE Publications 2019-04-09 /pmc/articles/PMC6457077/ /pubmed/31007921 http://dx.doi.org/10.1177/2050313X19841955 Text en © The Author(s) 2019 http://www.creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Case Report Weinstock, Barry S Haim, Yitzhak Daniel Pulmonary artery stenting in a patient with Takayasu’s arteritis using a novel balloon-expandable covered stent |
title | Pulmonary artery stenting in a patient with Takayasu’s arteritis
using a novel balloon-expandable covered stent |
title_full | Pulmonary artery stenting in a patient with Takayasu’s arteritis
using a novel balloon-expandable covered stent |
title_fullStr | Pulmonary artery stenting in a patient with Takayasu’s arteritis
using a novel balloon-expandable covered stent |
title_full_unstemmed | Pulmonary artery stenting in a patient with Takayasu’s arteritis
using a novel balloon-expandable covered stent |
title_short | Pulmonary artery stenting in a patient with Takayasu’s arteritis
using a novel balloon-expandable covered stent |
title_sort | pulmonary artery stenting in a patient with takayasu’s arteritis
using a novel balloon-expandable covered stent |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6457077/ https://www.ncbi.nlm.nih.gov/pubmed/31007921 http://dx.doi.org/10.1177/2050313X19841955 |
work_keys_str_mv | AT weinstockbarrys pulmonaryarterystentinginapatientwithtakayasusarteritisusinganovelballoonexpandablecoveredstent AT haimyitzhakdaniel pulmonaryarterystentinginapatientwithtakayasusarteritisusinganovelballoonexpandablecoveredstent |