Cargando…

Estimation of Breathing Rate with Confidence Interval Using Single-Channel CW Radar

Breathing rate monitoring using continuous wave (CW) radar has gained much attention due to its contact-less nature and privacy-friendly characteristic. In this work, using a single-channel CW radar, a breathing rate estimation method is proposed that deals with system nonlinearity of a single-chann...

Descripción completa

Detalles Bibliográficos
Autores principales: Nejadgholi, I., Sadreazami, H., Baird, Z., Rajan, S., Bolic, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6458880/
https://www.ncbi.nlm.nih.gov/pubmed/31049185
http://dx.doi.org/10.1155/2019/2658675
_version_ 1783410104737988608
author Nejadgholi, I.
Sadreazami, H.
Baird, Z.
Rajan, S.
Bolic, M.
author_facet Nejadgholi, I.
Sadreazami, H.
Baird, Z.
Rajan, S.
Bolic, M.
author_sort Nejadgholi, I.
collection PubMed
description Breathing rate monitoring using continuous wave (CW) radar has gained much attention due to its contact-less nature and privacy-friendly characteristic. In this work, using a single-channel CW radar, a breathing rate estimation method is proposed that deals with system nonlinearity of a single-channel CW radar and realizes a reliable breathing rate estimate by including confidence intervals. To this end, time-varying dominant Doppler frequency of radar signal, in the range of breathing rate, is extracted in time-frequency domain. It is shown through simulation and mathematical modeling that the average of the dominant Doppler frequencies over time provides an estimation of breathing rate. However, this frequency is affected by noise components and random body movements over time. To address this issue, the sum of these unwanted components is extracted in time-frequency domain, and from their surrogate versions, bootstrap resamples of the measured signal are obtained. Accordingly, a 95% confidence interval is calculated for breathing rate estimation using the bootstrap approach. The proposed method is validated in three different postures including lying down, sitting, and standing, with or without random body movements. The results show that using the proposed algorithm, estimation of breathing rate is feasible using single-channel CW radar. It is also shown that even in presence of random body movements, average of absolute error of estimation for all three postures is 1.88 breath per minute, which represents 66% improvement as compared to the Fourier transform-based approach.
format Online
Article
Text
id pubmed-6458880
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-64588802019-05-02 Estimation of Breathing Rate with Confidence Interval Using Single-Channel CW Radar Nejadgholi, I. Sadreazami, H. Baird, Z. Rajan, S. Bolic, M. J Healthc Eng Research Article Breathing rate monitoring using continuous wave (CW) radar has gained much attention due to its contact-less nature and privacy-friendly characteristic. In this work, using a single-channel CW radar, a breathing rate estimation method is proposed that deals with system nonlinearity of a single-channel CW radar and realizes a reliable breathing rate estimate by including confidence intervals. To this end, time-varying dominant Doppler frequency of radar signal, in the range of breathing rate, is extracted in time-frequency domain. It is shown through simulation and mathematical modeling that the average of the dominant Doppler frequencies over time provides an estimation of breathing rate. However, this frequency is affected by noise components and random body movements over time. To address this issue, the sum of these unwanted components is extracted in time-frequency domain, and from their surrogate versions, bootstrap resamples of the measured signal are obtained. Accordingly, a 95% confidence interval is calculated for breathing rate estimation using the bootstrap approach. The proposed method is validated in three different postures including lying down, sitting, and standing, with or without random body movements. The results show that using the proposed algorithm, estimation of breathing rate is feasible using single-channel CW radar. It is also shown that even in presence of random body movements, average of absolute error of estimation for all three postures is 1.88 breath per minute, which represents 66% improvement as compared to the Fourier transform-based approach. Hindawi 2019-03-28 /pmc/articles/PMC6458880/ /pubmed/31049185 http://dx.doi.org/10.1155/2019/2658675 Text en Copyright © 2019 I. Nejadgholi et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Nejadgholi, I.
Sadreazami, H.
Baird, Z.
Rajan, S.
Bolic, M.
Estimation of Breathing Rate with Confidence Interval Using Single-Channel CW Radar
title Estimation of Breathing Rate with Confidence Interval Using Single-Channel CW Radar
title_full Estimation of Breathing Rate with Confidence Interval Using Single-Channel CW Radar
title_fullStr Estimation of Breathing Rate with Confidence Interval Using Single-Channel CW Radar
title_full_unstemmed Estimation of Breathing Rate with Confidence Interval Using Single-Channel CW Radar
title_short Estimation of Breathing Rate with Confidence Interval Using Single-Channel CW Radar
title_sort estimation of breathing rate with confidence interval using single-channel cw radar
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6458880/
https://www.ncbi.nlm.nih.gov/pubmed/31049185
http://dx.doi.org/10.1155/2019/2658675
work_keys_str_mv AT nejadgholii estimationofbreathingratewithconfidenceintervalusingsinglechannelcwradar
AT sadreazamih estimationofbreathingratewithconfidenceintervalusingsinglechannelcwradar
AT bairdz estimationofbreathingratewithconfidenceintervalusingsinglechannelcwradar
AT rajans estimationofbreathingratewithconfidenceintervalusingsinglechannelcwradar
AT bolicm estimationofbreathingratewithconfidenceintervalusingsinglechannelcwradar