Cargando…

Efficacy, Safety, and Performance of Isolated Left vs. Right Ventricular Pacing in Patients with Bradyarrhythmias: A Randomized Controlled Trial

BACKGROUND: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias a...

Descripción completa

Detalles Bibliográficos
Autores principales: Crevelari, Elizabeth Sartori, da Silva, Katia Regina, Albertini, Caio Marcos de Moraes, Vieira, Marcelo Luiz Campos, Martinelli Filho, Martino, Costa, Roberto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Cardiologia - SBC 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6459436/
https://www.ncbi.nlm.nih.gov/pubmed/30994720
http://dx.doi.org/10.5935/abc.20180275
_version_ 1783410176870580224
author Crevelari, Elizabeth Sartori
da Silva, Katia Regina
Albertini, Caio Marcos de Moraes
Vieira, Marcelo Luiz Campos
Martinelli Filho, Martino
Costa, Roberto
author_facet Crevelari, Elizabeth Sartori
da Silva, Katia Regina
Albertini, Caio Marcos de Moraes
Vieira, Marcelo Luiz Campos
Martinelli Filho, Martino
Costa, Roberto
author_sort Crevelari, Elizabeth Sartori
collection PubMed
description BACKGROUND: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring heart rate correction alone. OBJECTIVE: To assess the safety, efficacy, and effects of LV pacing using an active-fixation coronary sinus lead in comparison with RV pacing, in patients eligible for conventional pacemaker (PM) implantation. METHODS: Randomized, controlled, and single-blinded clinical trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function ≥ 0.40. Randomization (RV vs. LV) occurred before PM implantation. The main results of the study were procedural success, safety, and efficacy. Secondary results were clinical and echocardiographic changes. Chi-squared test, Fisher's exact test and Student's t-test were used, considering a significance level of 5%. RESULTS: From June 2012 to January 2014, 91 patients were included, 36 in the RV Group and 55 in the LV Group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated into the LV group, active-fixation coronary sinus lead implantation was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations due to heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and 20.6% of those in the LV group (p = 0.767). Tissue Doppler analysis showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (p = 0.022). CONCLUSION: The procedural success rate of LV implant was low, and the safety of the procedure was influenced mainly by the high rate of phrenic nerve stimulation in the postoperative period.
format Online
Article
Text
id pubmed-6459436
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Sociedade Brasileira de Cardiologia - SBC
record_format MEDLINE/PubMed
spelling pubmed-64594362019-04-17 Efficacy, Safety, and Performance of Isolated Left vs. Right Ventricular Pacing in Patients with Bradyarrhythmias: A Randomized Controlled Trial Crevelari, Elizabeth Sartori da Silva, Katia Regina Albertini, Caio Marcos de Moraes Vieira, Marcelo Luiz Campos Martinelli Filho, Martino Costa, Roberto Arq Bras Cardiol Original Article BACKGROUND: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring heart rate correction alone. OBJECTIVE: To assess the safety, efficacy, and effects of LV pacing using an active-fixation coronary sinus lead in comparison with RV pacing, in patients eligible for conventional pacemaker (PM) implantation. METHODS: Randomized, controlled, and single-blinded clinical trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function ≥ 0.40. Randomization (RV vs. LV) occurred before PM implantation. The main results of the study were procedural success, safety, and efficacy. Secondary results were clinical and echocardiographic changes. Chi-squared test, Fisher's exact test and Student's t-test were used, considering a significance level of 5%. RESULTS: From June 2012 to January 2014, 91 patients were included, 36 in the RV Group and 55 in the LV Group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated into the LV group, active-fixation coronary sinus lead implantation was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations due to heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and 20.6% of those in the LV group (p = 0.767). Tissue Doppler analysis showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (p = 0.022). CONCLUSION: The procedural success rate of LV implant was low, and the safety of the procedure was influenced mainly by the high rate of phrenic nerve stimulation in the postoperative period. Sociedade Brasileira de Cardiologia - SBC 2019-04 /pmc/articles/PMC6459436/ /pubmed/30994720 http://dx.doi.org/10.5935/abc.20180275 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivative License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium provided the original work is properly cited and the work is not changed in any way.
spellingShingle Original Article
Crevelari, Elizabeth Sartori
da Silva, Katia Regina
Albertini, Caio Marcos de Moraes
Vieira, Marcelo Luiz Campos
Martinelli Filho, Martino
Costa, Roberto
Efficacy, Safety, and Performance of Isolated Left vs. Right Ventricular Pacing in Patients with Bradyarrhythmias: A Randomized Controlled Trial
title Efficacy, Safety, and Performance of Isolated Left vs. Right Ventricular Pacing in Patients with Bradyarrhythmias: A Randomized Controlled Trial
title_full Efficacy, Safety, and Performance of Isolated Left vs. Right Ventricular Pacing in Patients with Bradyarrhythmias: A Randomized Controlled Trial
title_fullStr Efficacy, Safety, and Performance of Isolated Left vs. Right Ventricular Pacing in Patients with Bradyarrhythmias: A Randomized Controlled Trial
title_full_unstemmed Efficacy, Safety, and Performance of Isolated Left vs. Right Ventricular Pacing in Patients with Bradyarrhythmias: A Randomized Controlled Trial
title_short Efficacy, Safety, and Performance of Isolated Left vs. Right Ventricular Pacing in Patients with Bradyarrhythmias: A Randomized Controlled Trial
title_sort efficacy, safety, and performance of isolated left vs. right ventricular pacing in patients with bradyarrhythmias: a randomized controlled trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6459436/
https://www.ncbi.nlm.nih.gov/pubmed/30994720
http://dx.doi.org/10.5935/abc.20180275
work_keys_str_mv AT crevelarielizabethsartori efficacysafetyandperformanceofisolatedleftvsrightventricularpacinginpatientswithbradyarrhythmiasarandomizedcontrolledtrial
AT dasilvakatiaregina efficacysafetyandperformanceofisolatedleftvsrightventricularpacinginpatientswithbradyarrhythmiasarandomizedcontrolledtrial
AT albertinicaiomarcosdemoraes efficacysafetyandperformanceofisolatedleftvsrightventricularpacinginpatientswithbradyarrhythmiasarandomizedcontrolledtrial
AT vieiramarceloluizcampos efficacysafetyandperformanceofisolatedleftvsrightventricularpacinginpatientswithbradyarrhythmiasarandomizedcontrolledtrial
AT martinellifilhomartino efficacysafetyandperformanceofisolatedleftvsrightventricularpacinginpatientswithbradyarrhythmiasarandomizedcontrolledtrial
AT costaroberto efficacysafetyandperformanceofisolatedleftvsrightventricularpacinginpatientswithbradyarrhythmiasarandomizedcontrolledtrial