Diagnostic accuracy of thromboelastometry and its correlation with the HPLC-MS/MS quantification test

The aim of the study was to evaluate the diagnostic accuracy of thromboelastometry for assessing rivaroxaban concentrations. The accuracy of thromboelastometry was compared with the high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method, which is the gold standard for dr...

Descripción completa

Detalles Bibliográficos
Autores principales: de Aranda, V.F., Derogis, P.B.M., Sanches, L.R., Mangueira, C.L.P., Katz, M., Faulhaber, A.C.L., Mendes, C.E.A., Ferreira, C.E. dos Santos, França, C.N., Guerra, J.C. de Campos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Associação Brasileira de Divulgação Científica 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6459466/
https://www.ncbi.nlm.nih.gov/pubmed/30970082
http://dx.doi.org/10.1590/1414-431X20198006
_version_ 1783410181621678080
author de Aranda, V.F.
Derogis, P.B.M.
Sanches, L.R.
Mangueira, C.L.P.
Katz, M.
Faulhaber, A.C.L.
Mendes, C.E.A.
Ferreira, C.E. dos Santos
França, C.N.
Guerra, J.C. de Campos
author_facet de Aranda, V.F.
Derogis, P.B.M.
Sanches, L.R.
Mangueira, C.L.P.
Katz, M.
Faulhaber, A.C.L.
Mendes, C.E.A.
Ferreira, C.E. dos Santos
França, C.N.
Guerra, J.C. de Campos
author_sort de Aranda, V.F.
collection PubMed
description The aim of the study was to evaluate the diagnostic accuracy of thromboelastometry for assessing rivaroxaban concentrations. The accuracy of thromboelastometry was compared with the high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method, which is the gold standard for drug plasma monitoring (the reference standard). Forty-six clinically stable patients were treated with 10, 15, or 20 mg of rivaroxaban once daily (OD group) or 15 mg twice a day (BID group) (no particular indication for treatment). Patient samples were collected 2 h after the use of the medication (peak) and 2 h before the next dose (trough). The rivaroxaban plasma concentrations were determined via HPLC-MS/MS, and thromboelastometry was performed using a ROTEM® delta analyzer. There were significant prolongations in clotting time (CT) for the 10, 15, and 20 mg of rivaroxaban treatments in the OD groups. In the 15 mg BID group, the responses at the peak and trough times were similar. At the peak times, there was a positive correlation between the plasma concentration of rivaroxaban and CT (Spearman correlation rho=0.788, P<0.001) and clot formation time (rho=0.784, P<0.001), and a negative correlation for alpha angle (rho=−0.771, P<0.001), amplitude after 5 min (rho=−0.763, P<0.001), and amplitude after 10 min (rho=−0.680, P<0.001). The CT presented higher specificity and sensitivity using the cut-off determined by the receiver characteristics curve. ROTEM has potential as screening tool to measure possible bleeding risk associated with rivaroxaban plasma levels.
format Online
Article
Text
id pubmed-6459466
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Associação Brasileira de Divulgação Científica
record_format MEDLINE/PubMed
spelling pubmed-64594662019-04-24 Diagnostic accuracy of thromboelastometry and its correlation with the HPLC-MS/MS quantification test de Aranda, V.F. Derogis, P.B.M. Sanches, L.R. Mangueira, C.L.P. Katz, M. Faulhaber, A.C.L. Mendes, C.E.A. Ferreira, C.E. dos Santos França, C.N. Guerra, J.C. de Campos Braz J Med Biol Res Research Article The aim of the study was to evaluate the diagnostic accuracy of thromboelastometry for assessing rivaroxaban concentrations. The accuracy of thromboelastometry was compared with the high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method, which is the gold standard for drug plasma monitoring (the reference standard). Forty-six clinically stable patients were treated with 10, 15, or 20 mg of rivaroxaban once daily (OD group) or 15 mg twice a day (BID group) (no particular indication for treatment). Patient samples were collected 2 h after the use of the medication (peak) and 2 h before the next dose (trough). The rivaroxaban plasma concentrations were determined via HPLC-MS/MS, and thromboelastometry was performed using a ROTEM® delta analyzer. There were significant prolongations in clotting time (CT) for the 10, 15, and 20 mg of rivaroxaban treatments in the OD groups. In the 15 mg BID group, the responses at the peak and trough times were similar. At the peak times, there was a positive correlation between the plasma concentration of rivaroxaban and CT (Spearman correlation rho=0.788, P<0.001) and clot formation time (rho=0.784, P<0.001), and a negative correlation for alpha angle (rho=−0.771, P<0.001), amplitude after 5 min (rho=−0.763, P<0.001), and amplitude after 10 min (rho=−0.680, P<0.001). The CT presented higher specificity and sensitivity using the cut-off determined by the receiver characteristics curve. ROTEM has potential as screening tool to measure possible bleeding risk associated with rivaroxaban plasma levels. Associação Brasileira de Divulgação Científica 2019-04-08 /pmc/articles/PMC6459466/ /pubmed/30970082 http://dx.doi.org/10.1590/1414-431X20198006 Text en https://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
de Aranda, V.F.
Derogis, P.B.M.
Sanches, L.R.
Mangueira, C.L.P.
Katz, M.
Faulhaber, A.C.L.
Mendes, C.E.A.
Ferreira, C.E. dos Santos
França, C.N.
Guerra, J.C. de Campos
Diagnostic accuracy of thromboelastometry and its correlation with the HPLC-MS/MS quantification test
title Diagnostic accuracy of thromboelastometry and its correlation with the HPLC-MS/MS quantification test
title_full Diagnostic accuracy of thromboelastometry and its correlation with the HPLC-MS/MS quantification test
title_fullStr Diagnostic accuracy of thromboelastometry and its correlation with the HPLC-MS/MS quantification test
title_full_unstemmed Diagnostic accuracy of thromboelastometry and its correlation with the HPLC-MS/MS quantification test
title_short Diagnostic accuracy of thromboelastometry and its correlation with the HPLC-MS/MS quantification test
title_sort diagnostic accuracy of thromboelastometry and its correlation with the hplc-ms/ms quantification test
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6459466/
https://www.ncbi.nlm.nih.gov/pubmed/30970082
http://dx.doi.org/10.1590/1414-431X20198006
work_keys_str_mv AT dearandavf diagnosticaccuracyofthromboelastometryanditscorrelationwiththehplcmsmsquantificationtest
AT derogispbm diagnosticaccuracyofthromboelastometryanditscorrelationwiththehplcmsmsquantificationtest
AT sancheslr diagnosticaccuracyofthromboelastometryanditscorrelationwiththehplcmsmsquantificationtest
AT mangueiraclp diagnosticaccuracyofthromboelastometryanditscorrelationwiththehplcmsmsquantificationtest
AT katzm diagnosticaccuracyofthromboelastometryanditscorrelationwiththehplcmsmsquantificationtest
AT faulhaberacl diagnosticaccuracyofthromboelastometryanditscorrelationwiththehplcmsmsquantificationtest
AT mendescea diagnosticaccuracyofthromboelastometryanditscorrelationwiththehplcmsmsquantificationtest
AT ferreiracedossantos diagnosticaccuracyofthromboelastometryanditscorrelationwiththehplcmsmsquantificationtest
AT francacn diagnosticaccuracyofthromboelastometryanditscorrelationwiththehplcmsmsquantificationtest
AT guerrajcdecampos diagnosticaccuracyofthromboelastometryanditscorrelationwiththehplcmsmsquantificationtest